83 research outputs found

    Monitoring mitochondrial PO2: the next step

    Get PDF
    PURPOSE OF REVIEW: To fully exploit the concept of hemodynamic coherence in resuscitating critically ill one should preferably take into account information about the state of parenchymal cells. Monitoring of mitochondrial oxygen tension (mitoPO2) has emerged as a clinical means to assess information of oxygen delivery and oxygen utilization at the mitochondrial level. This review will outline the basics of the technique, summarize its development and describe the rationale of measuring oxygen at the mitochondrial level. RECENT FINDINGS: Mitochondrial oxygen tension can be measured by means of the protoporphyrin IX-Triplet State Lifetime Technique (PpIX-TSLT). After validation and use in preclinical animal models, the technique has recently become commercially available in the form of a clinical measuring system. This system has now been used in a number of healthy volunteer studies and is currently being evaluated in studies in perioperative and intensive care patients in several European university hospitals. SUMMARY: PpIX-TSLT is a noninvasive and well tolerated method to assess aspects of mitochondrial functio

    Non-invasive monitoring of mitochondrial oxygenation and respiration in critical illness using a novel technique

    Get PDF
    Introduction: Although mitochondrial dysfunction is proposed to be involved in the pathophysiology of sepsis, conflicting results are reported. Variation in methods used to assess mitochondrial function might contribute to this controversy. A non-invasive method for monitoring mitochondrial function might help overcome this limitation. Therefore, this study explores the possibility o

    Influence of fluid resuscitation on renal microvascular PO(2 )in a normotensive rat model of endotoxemia

    Get PDF
    INTRODUCTION: Septic renal failure is often seen in the intensive care unit but its pathogenesis is only partly understood. This study, performed in a normotensive rat model of endotoxemia, tests the hypotheses that endotoxemia impairs renal microvascular PO(2 )(μPO(2)) and oxygen consumption (VO(2,ren)), that endotoxemia is associated with a diminished kidney function, that fluid resuscitation can restore μPO(2), VO(2,ren )and kidney function, and that colloids are more effective than crystalloids. METHODS: Male Wistar rats received a one-hour intravenous infusion of lipopolysaccharide, followed by resuscitation with HES130/0.4 (Voluven(®)), HES200/0.5 (HES-STERIL(® )(® )6%) or Ringer's lactate. The renal μPO(2 )in the cortex and medulla and the renal venous PO(2 )were measured by a recently published phosphorescence lifetime technique. RESULTS: Endotoxemia induced a reduction in renal blood flow and anuria, while the renal μPO(2 )and VO(2,ren )remained relatively unchanged. Resuscitation restored renal blood flow, renal oxygen delivery and kidney function to baseline values, and was associated with oxygen redistribution showing different patterns for the different compounds used. HES200/0.5 and Ringer's lactate increased the VO(2,ren), in contrast to HES130/0.4. CONCLUSION: The loss of kidney function during endotoxemia could not be explained by an oxygen deficiency. Renal oxygen redistribution could for the first time be demonstrated during fluid resuscitation. HES130/0.4 had no influence on the VO(2,ren )and restored renal function with the least increase in the amount of renal work

    Mitochondrial Oxygen Monitoring During Surgical Repair of Congenital Diaphragmatic Hernia or Esophageal Atresia: A Feasibility Study

    Get PDF
    Current monitoring techniques in neonates lack sensitivity for hypoxia at cellular level. The recent introduction of the non-invasive Cellular Oxygen METabolism (COMET) monitor enables measuring in vivo mitochondrial oxygen tension (mitoPO2), based on oxygen-dependent quenching of delayed fluorescence of 5-aminolevulinic acid (ALA)-enhanced protoporphyri

    Comparison between pulse wave velocities measured using Complior and measured using Biopac

    Get PDF
    Arterial stiffness is a reliable prognostic parameter for cardiovascular diseases. The effect of change in arterial stiffness can be measured by the change of the pulse wave velocity (PWV). The Complior system is widely used to measure PWV between the carotid and radial arteries by means of piezoelectric clips placed around the neck and the wrist. The Biopac system is an easier to use alternative that uses ECG and simple optical sensors to measure the PWV between the heart and the fingertips, and thus extends a bit more to the peripheral vasculature compared to the Complior system. The goal of this study was to test under various conditions to what extent these systems provide comparable and correlating values. 25 Healthy volunteers, 20–30 years old, were measured in four sequential position: sitting, lying, standing and sitting. The results showed that the Biopac system measured consistently and significantly lower PWV values than the Complior system, for all positions. Correlation values and Bland–Altman plots showed that despite the difference in PWV magnitudes obtained by the two systems the measurements did agree well. Which implies that as long as the differences in PWV magnitudes are taken into account, either system could be used to measure PWV changes over time. However, when basing diagnosis on absolute PWV values, one should be very much aware of how the PWV was measured and with what system

    Monitoring of mitochondrial oxygenation during perioperative blood loss

    Get PDF
    One of the challenges in the management of acute blood loss is to differentiate whether blood transfusion is required or not. The sole use of haemoglobin values might lead to unnecessary transfusion in individual cases. The suggestion is that mitochondrial oxygen tension can be used as an additional monitoring technique to determine when blood transfusion is required. In this case report, we report mitochondrial oxygen measurements in a patient with perioperative blood loss requiring blood transfusion

    Study protocol and pilot results of an observational cohort study evaluating effect of red blood cell transfusion on oxygenation and mitochondrial oxygen tension in critically ill patients with anaemia: the INsufficient Oxygenation in the Intensive Care Unit (INOX ICU-2) study

    Get PDF
    INTRODUCTION: The recently developed protoporphyrin IX-triple state lifetime technique measures mitochondrial oxygenation tension (mitoPO2) in vivo at the bedside. MitoPO2might be an early indicator of oxygen disbalance in cells of critically ill patients and therefore m

    Optimizing working space in laparoscopy: CT-measurement of the effect of neuromuscular blockade and its reversal in a porcine model

    Get PDF
    Objective: The objective of this paper was to determine the effect of neuromuscular blockade (NMB) on working space in a porcine laparoscopy model. Background: Conflicting results on the effect of NMB on laparoscopic working space are found in literature. Almost all studies are limited by absence of objective assessment of working space or use surrogate outcomes. Methods: In a standardized porcine laparoscopy model, laparoscopic working-space dimensions with and without NMB were investigated in 16 animals using computed tomography at intra-abdominal pressures of 0, 5, 10, and 15 mmHg during multiple runs of abdominal insufflation. Results: No statistically significant effect of NMB on abdominal dimensions and laparoscopic working-space volume was found during CO2 pneumoperitoneum. In contrast, the effect of pre-stretching of the abdominal wall by a previous abdominal insufflation was found to be significant. Conclusions: This experimental study confirms the results from several clinical studies that NMB does not influence laparoscopic working space. Studies dealing with working space during laparoscopy should take note of pre-stretching bias

    Measuring Mitochondrial Oxygen Tension during Red Blood Cell Transfusion in Chronic Anemia Patients:A Pilot Study

    Get PDF
    In light of the associated risks, the question has been raised whether the decision to give a blood transfusion should solely be based on the hemoglobin level. As mitochondria are the final destination of oxygen transport, mitochondrial parameters are suggested to be of added value. The aims of this pilot study were to investigate the effect of a red blood cell transfusion on mitochondrial oxygenation as measured by the COMET device in chronic anemia patients and to explore the clinical usability of the COMET monitor in blood transfusion treatments, especially the feasibility of performing measurements in an outpatient setting. To correct the effect of volume load on mitochondrial oxygenation, a red blood cell transfusion and a saline infusion were given in random order. In total, 21 patients were included, and this resulted in 31 observations. If patients participated twice, the order of infusion was reversed. In both the measurements wherein a blood transfusion was given first and wherein 500 mL of 0.9% saline was given first, the median mitochondrial oxygen tension decreased after red blood cell transfusion. The results of this study have strengthened the need for further research into the effect of blood transfusion tissue oxygenation and the potential role of mitochondrial parameters herein.</p

    A monitor for Cellular Oxygen METabolism (COMET): monitoring tissue oxygenation at the mitochondrial level

    Get PDF
    After introduction of the protoporphyrin IX-triplet state lifetime technique as a new method to measure mitochondrial oxygen tension in vivo, the development of a clinical monitor was started. This monitor is the “COMET”, an acronym for Cellular Oxygen METabolism. The COMET is a non-invasive electrically powered optical device that allows measurements on the skin. The COMET is easy to transport, due to its lightweight and compact size. After 5-aminolevulinic acid application on the human skin, a biocompatible sensor enables detection of PpIX in the mitochondria. PpIX acts as a mitochondrially located oxygen-sensitive dye. Three measurement types are available in the touchscreen-integrated user interface, ‘Single’, ‘Interval’ and ‘Dynamic measurement’. COMET is currently used in several clinical studies in our institution. In this first description of the COMET device we show an incidental finding during neurosurgery. To treat persisting intraoperative hypertension a patient was administered clonidine, but due to rapid administration an initial phase of peripheral vasoconstriction occurred. Microvascular flow and velocity parameters measured with laser-doppler (O2C, LEA Medizintechnik) decreased by 44 and 16% respectively, but not the venous-capillary oxygen saturation. However, mitochondrial oxygen tension in the skin detected by COMET decreased from a steady state of 48 to 16 mmHg along with the decrease in flow and velocity. We conclude that COMET is ready for clinical application and we see the future for this bedside monitor on the intensive care, operating theater, and testing of mitochondrial effect of pharmaceuticals
    corecore