36 research outputs found

    Sustained release of locally delivered celecoxib provides pain relief for osteoarthritis: a proof of concept in dog patients

    Get PDF
    Objective: Drug delivery platforms that allow for gradual drug release after intra-articular administration have become of much interest as a treatment strategy for osteoarthritis (OA). The aim of this study was to investigate the safety and efficacy of an intra-articular sustained release formulation containing celecoxib (CXB), a cyclooxygenase-2 (COX-2) selective inhibitor. Methods: Amino acid-based polyesteramide microspheres (PEAMs), a biodegradable and non-toxic platform, were loaded with CXB and employed in two in vivo models of arthritis: an acute inflammatory arthritis model in rats (n = 12), and a randomized controlled study in chronic OA dog patients (n = 30). In parallel, the bioactivity of sustained release of CXB was evaluated in monolayer cultures of primary dog chondrocytes under inflammatory conditions. Results: Sustained release of CXB did not alleviate acute arthritis signs in the rat arthritis model, based on pain measurements and synovitis severity. However, in OA dog patients, sustained release of CXB improved limb function as objective parameter of pain and quality of life based on gait analysis and owner questionnaires. It also decreased pain medication dependency over a 2-month period and caused no adverse effects. Prostaglandin E2 levels, a marker for inflammation, were lower in the synovial fluid of CXB-treated dog OA patients and in CXB-treated cultured dog chondrocytes. Conclusion: These results show that local sustained release of CXB is less suitable to treat acute inflammation in arthritic joints, while safe and effective in treating pain in chronic OA in dogs

    Photo-crosslinked networks prepared from fumaric acid monoethyl ester-functionalized poly(D,L-lactic acid) oligomers and N-vinyl-2-pyrrolidone for the controlled and sustained release of proteins

    Get PDF
    Photo-crosslinked networks were prepared from fumaric acid monoethyl ester-functionalized poly (D,L-lactic acid) oligomers and N-vinyl-2-pyrrolidone. Two model proteins, lysozyme and albumin, were incorporated into the network films as solid particles and their release behavior was studied. By varying the NVP content and macromer molecular weight the degradation behavior and protein release profiles of the prepared networks could be tuned. The more hydrophilic and less densely crosslinked networks released albumin and lysozyme at a faster rate. Although active lysozyme was released from the networks over the complete release period, lysozyme release was often incomplete. This was most likely caused by electrostatic and/or hydrophobic interactions between the protein and the degrading polymer network. (C) 2012 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved

    Controlling the kinetic chain length of the crosslinks in photo-polymerized biodegradable networks

    Get PDF
    Biodegradable polymer networks were prepared by photo-initiated radical polymerization of methacrylate functionalized poly(d,l-lactide) oligomers. The kinetic chains formed in this radical polymerization are the multifunctional crosslinks of the networks. These chains are carbon–carbon chains that remain after degradation. If their molecular weight is too high these poly(methacrylic acid) chains can not be excreted by the kidneys. The effect of the photo-initiator concentration and the addition of 2-mercaptoethanol as a chain transfer agent on the molecular weight of the kinetic chains was investigated. It was found that both increasing the initiator concentration and adding 2-mercaptoethanol decrease the kinetic chain length. However, the effect of adding 2-mercaptoethanol was much larger. Some network properties such as the glass transition temperature and the swelling ratio in acetone are affected when the kinetic chain length is decrease

    Safety of intradiscal delivery of triamcinolone acetonide by a poly(esteramide) microsphere platform in a large animal model of intervertebral disc degeneration

    No full text
    BACKGROUND CONTEXT: Local corticosteroids have been used to relieve symptoms of chronic low back pain, although treatment effects have been shown to wear off relatively fast. Prolonging corticosteroid presence by controlled release from biomaterials may allow for longer pain relief while circumventing adverse effects such as high bolus dosages. PURPOSE: The purpose of this study was to evaluate the safety and efficacy of intradiscal controlled release of triamcinolone acetonide (TAA) by poly(esteramide) microspheres in a canine degenerated intervertebral disc (IVD) model. STUDY DESIGN: In a preclinical experimental large animal model, the effect of prolonged glucocorticoid exposure on disc degeneration was evaluated. METHODS: Degeneration was accelerated by nucleotomy of lumbar IVDs of Beagle dogs. After 4 weeks, microspheres loaded with 8.4 µg TAA, and 0.84mg TAA were administered to the degenerated IVDs by intradiscal injection (n=6 per group). Empty microspheres (n=6) and all adjacent non-nucleotomized noninjected IVDs were included as controls (n=24). Immediately prior to TAA administration and after 12 weeks, magnetic resonance imaging was performed. Degenerative changes were evaluated by disc height index, Pfirrmann grading, T1ρ and T2 mapping values, postmortem CT scans, macroscopic and microscopic grading, and biochemical/immunohistochemical analysis of inflammation and extracellular matrix content. In addition, nerve growth factor (NGF) protein expression, a biomarker for pain, was scored in nucleus pulposus (NP) tissues. The study was funded by a research grant from Health Holland (1.3million euros = 1.5million US dollars). RESULTS: Macroscopic evaluation and CT images postmortem were consistent with mild disc degeneration. Other abnormalities were not observed. Nucleotomy-induced degeneration and inflammation was mild, reflected by moderate Pfirrmann grades and PGE2 levels. Regardless of TAA dosage, local sustained delivery did not affect disc height index nor Pfirrmann grading, T1ρ and T2 mapping values, PGE2 tissue levels, collagen, GAG, and DNA content. However, the low dosage of TAA microspheres significantly reduced NGF immunopositivity in degenerated NP tissue. CONCLUSIONS: This is the first in vivo application in a preclinical large animal model of a controlled release formulation of corticosteroids in mild IVD degeneration. Sustained release of TAA locally in the IVD appeared safe and reduced NGF expression, suggesting its potential applicability for pain relief, although beneficial effects were absent on tissue degeneration. CLINICAL SIGNIFICANCE: The present platform seems to be promising in extending the local controlled delivery of TAA with the potency to provide long-standing analgesia in the subset of LBP patients suffering from discogenic pain

    Intra-articular injection of triamcinolone acetonide releasing biomaterial microspheres inhibits pain and inflammation in an acute arthritis model

    No full text
    Inflammation of the synovium and joint capsule is a main driver of pain in an osteoarthritic (OA) joint. Triamcinolone acetonide (TAA) is a classical corticosteroid that reduces synovitis and alleviates pain, albeit transiently. Biomaterial-based local TAA release may prolong the suppression of pain without the need for multiple injections. Polylactic-co-glycolic acid (PLGA) formulations of TAA prolong OA pain relief to a limited extent. A novel polyesteramide (PEA) microsphere platform allows for extended release in the OA joint for over 3 months. To evaluate their effect on pain and inflammation, TAA-loaded microspheres were intra-articularly delivered to the knee joint in a rat model of acute arthritis induced by intra-articular injection of streptococcal cell wall peptidoglycan-polysaccharide (PGPS) and subsequent flare-ups by intravenous PGPS injections. PEA-loaded microspheres were benchmarked with TAA-loaded PLGA microspheres and bolus TAA injection. TAA treatments were injected intra-articularly before the first induced flare-up. TAA-loaded PEA and PLGA microspheres reduced joint swelling and signs of pain-like behavior over the entire study period, as assessed by weight bearing and referred mechanical hypersensitivity, whereas bolus suspension was effective for a shorter time period. TAA-loaded PEA microspheres reduced lameness to a greater extent than TAA-loaded PLGA microspheres. In conclusion, a single intra-articular injection of TAA-loaded PEA microspheres reduced joint swelling and induced longer pain relief compared to bolus injection. Hence relief of inflammation and pain by PEA-based delivery of TAA may prove to be effective and durable

    Intra-articular injection of triamcinolone acetonide releasing biomaterial microspheres inhibits pain and inflammation in an acute arthritis model

    No full text
    Inflammation of the synovium and joint capsule is a main driver of pain in an osteoarthritic (OA) joint. Triamcinolone acetonide (TAA) is a classical corticosteroid that reduces synovitis and alleviates pain, albeit transiently. Biomaterial-based local TAA release may prolong the suppression of pain without the need for multiple injections. Polylactic-co-glycolic acid (PLGA) formulations of TAA prolong OA pain relief to a limited extent. A novel polyesteramide (PEA) microsphere platform allows for extended release in the OA joint for over 3 months. To evaluate their effect on pain and inflammation, TAA-loaded microspheres were intra-articularly delivered to the knee joint in a rat model of acute arthritis induced by intra-articular injection of streptococcal cell wall peptidoglycan-polysaccharide (PGPS) and subsequent flare-ups by intravenous PGPS injections. PEA-loaded microspheres were benchmarked with TAA-loaded PLGA microspheres and bolus TAA injection. TAA treatments were injected intra-articularly before the first induced flare-up. TAA-loaded PEA and PLGA microspheres reduced joint swelling and signs of pain-like behavior over the entire study period, as assessed by weight bearing and referred mechanical hypersensitivity, whereas bolus suspension was effective for a shorter time period. TAA-loaded PEA microspheres reduced lameness to a greater extent than TAA-loaded PLGA microspheres. In conclusion, a single intra-articular injection of TAA-loaded PEA microspheres reduced joint swelling and induced longer pain relief compared to bolus injection. Hence relief of inflammation and pain by PEA-based delivery of TAA may prove to be effective and durable

    Intra-articular injection of triamcinolone acetonide releasing biomaterial microspheres inhibits pain and inflammation in an acute arthritis model

    No full text
    Inflammation of the synovium and joint capsule is a main driver of pain in an osteoarthritic (OA) joint. Triamcinolone acetonide (TAA) is a classical corticosteroid that reduces synovitis and alleviates pain, albeit transiently. Biomaterial-based local TAA release may prolong the suppression of pain without the need for multiple injections. Polylactic-co-glycolic acid (PLGA) formulations of TAA prolong OA pain relief to a limited extent. A novel polyesteramide (PEA) microsphere platform allows for extended release in the OA joint for over 3 months. To evaluate their effect on pain and inflammation, TAA-loaded microspheres were intra-articularly delivered to the knee joint in a rat model of acute arthritis induced by intra-articular injection of streptococcal cell wall peptidoglycan-polysaccharide (PGPS) and subsequent flare-ups by intravenous PGPS injections. PEA-loaded microspheres were benchmarked with TAA-loaded PLGA microspheres and bolus TAA injection. TAA treatments were injected intra-articularly before the first induced flare-up. TAA-loaded PEA and PLGA microspheres reduced joint swelling and signs of pain-like behavior over the entire study period, as assessed by weight bearing and referred mechanical hypersensitivity, whereas bolus suspension was effective for a shorter time period. TAA-loaded PEA microspheres reduced lameness to a greater extent than TAA-loaded PLGA microspheres. In conclusion, a single intra-articular injection of TAA-loaded PEA microspheres reduced joint swelling and induced longer pain relief compared to bolus injection. Hence relief of inflammation and pain by PEA-based delivery of TAA may prove to be effective and durable

    Applicability of a Modified Rat Model of Acute Arthritis for Long-Term Testing of Drug Delivery Systems

    No full text
    Episodes of inflammation and pain are predominant features of arthritic joint diseases. Drug delivery systems (DDS) could reduce inflammation and pain long-term without chances of infection upon multiple injections. To allow for long-term evaluation of DDS, we modified a previously published acute arthritis model by extending follow-up periods between flare-ups. Unilateral synovial inflammation of the knee was induced by intra-articular injection of streptococcal cell wall peptidoglycan polysaccharide (PGPS), and flare-ups were induced by intravenous PGPS injections every 4 weeks for a total duration of 84 days. In PGPS-reactivated animals, joint swelling, pain behavior, post mortem synovitis, and osteophyte formation were notable features. Hepatitis, splenitis and inflammation of non-primed joints were observed as systemic side effects. To test the applicability of the modified arthritis model for long-term testing of DDS, the duration of anti-inflammatory and analgesic effects of a corticosteroid released from two different polymer-based platforms was evaluated. The current modified arthritis model has good applicability for testing of DDS for a prolonged period of time. Furthermore, the novel autoregulatory polyesteramide (PEA) microsphere platform releasing triamcinolone acetonide (TAA) was benchmarked against poly lactic-co-glycolic acid (PLGA) and reduced joint swelling and pain behavior more potently compared to TAA-loaded PLGA microspheres
    corecore