21 research outputs found

    Noninvasive measurement of plasma triglycerides and free fatty acids from exhaled breath.

    Get PDF
    BackgroundAlthough altered metabolism has long been known to affect human breath, generating clinically usable metabolic tests from exhaled compounds has proven challenging. If developed, a breath-based lipid test would greatly simplify management of diabetes and serious pathological conditions (e.g., obesity, familial hyperlipidemia, and coronary artery disease), in which systemic lipid levels are a critical risk factor for onset and development of future cardiovascular events.MethodsWe, therefore, induced controlled fluctuations of plasma lipids (insulin-induced lipid suppression or intravenous infusion of Intralipid) during 4-h in vivo experiments on 23 healthy volunteers (12 males/11 females, 28.0 ± 0.3 years) to find correlations between exhaled volatile organic compounds and plasma lipids. In each subject, plasma triglycerides (TG) and free fatty acids (FFA) concentrations were both directly measured and calculated via individualized prediction equations based on the multiple linear regression analysis of a cluster of 4 gases. In the lipid infusion protocol, we also generated common prediction equations using a maximum of 10 gases.ResultsThis analysis yielded strong correlations between measured and predicted values during both lipid suppression (r = 0.97 for TG; r = 0.90 for FFA) and lipid infusion (r = 0.97 for TG; r = 0.94 for FFA) studies. In our most accurate common prediction model, measured and predicted TG and FFA values also displayed very strong statistical agreement (r = 0.86 and r = 0.81, respectively).ConclusionsOur results demonstrate the feasibility of measuring plasma lipids through breath analysis. Optimization of this technology may ultimately lead to the development of portable breath analyzers for plasma lipids, replacing blood-based bioassays

    Approach to Using Trend Arrows in the FreeStyle Libre Flash Glucose Monitoring Systems in Adults

    No full text
    The use of personal continuous glucose monitoring (CGM) has expanded dramatically among individuals with diabetes. CGM systems provide retrospective data, as well as the current glucose value and trend arrow data, which indicate the direction and velocity of changing glucose. In 2017, Aleppo and colleagues developed a simplified approach for adults with diabetes to safely adjust rapid-acting insulin doses using trend arrow information in the Dexcom G5 CGM system. Since then, the FreeStyle Libre and FreeStyle Libre 14-day CGM systems have become available in the United States; however, guidance on using trend arrow data that take the unique features of these systems into consideration is lacking. Specifically, the FreeStyle Libre systems do not have automatic alarms, which impact how the system and trend arrow data are used. The Endocrine Society convened an expert panel to address this gap and develop an approach to adjusting rapid-acting insulin doses for adults using trend arrows in the FreeStyle Libre systems. We based our approach on previous work and expanded upon engagement and scanning recommendations, and we incorporated pre-exercise planning specific to these systems. Our approach provides insulin dose adjustments as discrete insulin units based on an individual\u27s insulin sensitivity and directionality of the trend arrow. We focus on the needs of patients treated with multiple daily injections because these individuals currently make up a greater proportion of individuals on intensive insulin therapy. Our recommendations are intended to provide a safe, practical approach to using trend arrows in the FreeStyle Libre systems

    Characterization of volatile organic compounds (VOCs) in Asian and north American pollution plumes during INTEX-B: identification of specific Chinese air mass tracers

    Get PDF
    We present results from the Intercontinental Chemical Transport Experiment - Phase B (INTEX-B) aircraft mission conducted in spring 2006. By analyzing the mixing ratios of volatile organic compounds (VOCs) measured during the second part of the field campaign, together with kinematic back trajectories, we were able to identify five plumes originating from China, four plumes from other Asian regions, and three plumes from the United States. To identify specific tracers for the different air masses we characterized their VOC composition and we compared their background levels with those obtained during the 2004 INTEX-A mission. The Chinese and other Asian air masses were significantly enhanced in carbonyl sulfide (OCS) and methyl chloride (CH3Cl), while all CFC replacement compounds were elevated in US plumes, particularly HFC-134a. Although elevated mixing ratios of Halon-1211 were measured in some Chinese plume samples, several measurements at background levels were also observed. After analyzing the VOC distribution and correlations within the Chinese pollution plumes and applying principal component analysis (PCA), we suggest the use of a suite of species, rather than a single gas, as specific tracers of Chinese air masses (namely OCS, CH3Cl, 1,2-dichloroethane, ethyl chloride, and Halon-1211). In an era of constantly changing halocarbon usage patterns, this suite of gases best reflects new emission characteristics from China

    The continuum between GH deficiency and GH insensitivity in children

    No full text
    The continuum of growth hormone (GH)-IGF-I axis defects extends from severe to mild GH deficiency, through short stature disorders of undefined aetiology, to GH insensitivity disorders which can also be mild or severe. This group of defects comprises a spectrum of endocrine, biochemical, phenotypic and genetic abnormalities. The extreme cases are generally easily diagnosed because they conform to well-studied phenotypes with recognised biochemical features. The milder cases of both GH deficiency and GH insensitivity are less well defined and also overlap with the group of short stature conditions, labelled as idiopathic short stature (ISS). In this review the continuum model, which plots GH sensitivity against GH secretion, will be discussed. Defects causing GH deficiency and GH insensitivity will be described, together with the use of a diagnostic algorithm, designed to aid investigation and categorisation of these defects. The continuum will also be discussed in the context of growth-promoting endocrine therapy
    corecore