236 research outputs found

    Geomorphological map of the Lipari volcanic island (Aeolian Archipelago – Italy)

    Get PDF
    A 1:10,000-scale geomorphological map of the Lipari volcanic island (Aeolian Archipelago – Italy) is presented in this paper. The associated map, which includes volcanic and epivolcanic landforms, is obtained combining the available geological information with data derived from the analysis of a digital terrain model, integrated with aerial photographic observations and field surveys. The map shows that the location of the main volcanic morphologies is strongly controlled by local tectonic structures striking NNW-SSE, while the epivolcanic morphologies are mainly related to the continuous uplift induced by the prevalence of regional tectonic processes. The aim of this work is to provide an improved geomorphological map, with a reasonably comprehensive overview of the landforms present in the most densely populated island of the Aeolian Archipelago. This map can be also used as a support for future studies of land management on the island

    The effect of postmastectomy radiation therapy on breast implants. Material analysis on silicone and polyurethane prosthesis

    Get PDF
    The pathogenic mechanism underlying capsular contracture is still unknown. It is certainly a multifactorial process, resulting from human body reaction, biofilm activation, bacteremic seeding, or silicone exposure. The scope of the present article is to investigate the effect of hypofractionated radiotherapy protocol (2.66 Gy × 16 sessions) both on silicone and polyurethane breast implants.Silicone implants and polyurethane underwent irradiation according to a hypofractionated radiotherapy protocol for the treatment of breast cancer. After irradiation implant shells underwent mechanical, chemical, and microstructural evaluation by means of tensile testing, infrared spectra in attenuated total reflectance mode, nuclear magnetic resonance, and field emission scanning electron microscopy.At superficial analysis, irradiated silicone samples show several visible secondary and tertiary blebs. Polyurethane implants showed an open cell structure, which closely resembles a sponge. Morphological observation of struts from treated polyurethane sample shows a more compact structure, with significantly shorter and thicker struts compared with untreated sample. The infrared spectra in attenuated total reflectance mode spectra of irradiated and control samples were compared either for silicon and polyurethane samples. In the case of silicone-based membranes, treated and control specimens showed similar bands, with little differences in the treated one. Nuclear magnetic resonance spectra on the fraction soluble in CDCl3 support these observations. Tensile tests on silicone samples showed a softer behavior of the treated ones. Tensile tests on Polyurethane samples showed no significant differences.Polyurethane implants seem to be more resistant to radiotherapy damage, whereas silicone prosthesis showed more structural, mechanical, and chemical modifications

    Cardiac pacemaker battery discharge after external electrical cardioversion for broad QRS Complex Tachycardia

    Get PDF
    External electrical cardioversion or defibrillation may be necessary in patients with implanted cardiac pacemaker (PM) or implantable cardioverter defibrillator (ICD). Sudden discharge of high electrical energy employed in direct current (DC) transthoracic countershock may damage the PM/ICD system resulting in a series of possible device malfunctions. For this reason, when defibrillation or cardioversion must be attempted in a patient with a PM or ICD, some precautions should be taken, particularly in PM dependent patients, in order to prevent damage to the device. We report the case of a 76-year-old woman with a dual chamber PM implanted in the right subclavicular region, who received two consecutive transthoracic DC shocks to treat haemodynamically unstable broad QRS complex tachycardia after cardiac surgery performed with a standard sternotomic approach. Because of the sternal wound and thoracic drainage tubes together with the severe clinical compromise, the anterior paddle was positioned near the pulse generator. At the following PM test, a complete battery discharge was detected

    Cardiac Pacemaker Battery Discharge After External Electrical Cardioversion for Broad QRS Complex Tachycardia

    Get PDF
    External electrical cardioversion or defibrillation may be necessary in patients with implanted cardiac pacemaker (PM) or implantable cardioverter defibrillator (ICD). Sudden discharge of high electrical energy employed in direct current (DC) transthoracic countershock may damage the PM/ICD system resulting in a series of possible device malfunctions. For this reason, when defibrillation or cardioversion must be attempted in a patient with a PM or ICD, some precautions should be taken, particularly in PM dependent patients, in order to prevent damage to the device. We report the case of a 76-year-old woman with a dual chamber PM implanted in the right subclavicular region, who received two consecutive transthoracic DC shocks to treat haemodynamically unstable broad QRS complex tachycardia after cardiac surgery performed with a standard sternotomic approach. Because of the sternal wound and thoracic drainage tubes together with the severe clinical compromise, the anterior paddle was positioned near the pulse generator. At the following PM test, a complete battery discharge was detected

    Metabolic Signature of Arrhythmogenic Cardiomyopathy

    Get PDF
    Arrhythmogenic cardiomyopathy (ACM) is a genetic-based cardiac disease accompanied by severe ventricular arrhythmias and a progressive substitution of the myocardium with fibro-fatty tissue. ACM is often associated with sudden cardiac death. Due to the reduced penetrance and variable expressivity, the presence of a genetic defect is not conclusive, thus complicating the diagnosis of ACM. Recent studies on human induced pluripotent stem cells-derived cardiomyocytes (hiPSC-CMs) obtained from ACM individuals showed a dysregulated metabolic status, leading to the hypothesis that ACM pathology is characterized by an impairment in the energy metabolism. However, despite efforts having been made for the identification of ACM specific biomarkers, there is still a substantial lack of information regarding the whole metabolomic profile of ACM patients. The aim of the present study was to investigate the metabolic profiles of ACM patients compared to healthy controls (CTRLs). The targeted Biocrates AbsoluteIDQ® p180 assay was used on plasma samples. Our analysis showed that ACM patients have a different metabolome compared to CTRLs, and that the pathways mainly affected include tryptophan metabolism, arginine and proline metabolism and beta oxidation of fatty acids. Altogether, our data indicated that the plasma metabolomes of arrhythmogenic cardiomyopathy patients show signs of endothelium damage and impaired nitric oxide (NO), fat, and energy metabolism

    Comparison between First- and Second-Generation Cryoballoon for Paroxysmal Atrial Fibrillation Ablation

    Get PDF
    Introduction. Cryoballoon (CB) ablation has emerged as a novel treatment for pulmonary vein isolation (PVI) for patients with paroxysmal atrial fibrillation (PAF). The second-generation Arctic Front Advance (ADV) was redesigned with technical modifications aiming at procedural and outcome improvements. We aimed to compare the efficacy of the two different technologies over a long-term follow-up. Methods. A total of 120 patients with PAF were enrolled. Sixty patients underwent PVI using the first-generation CB and 60 patients with the ADV catheter. All patients were evaluated over a follow-up period of 2 years. Results. There were no significant differences between the two groups of patients. Procedures performed with the first-generation CB showed longer fluoroscopy time (36.3±16.8 versus 14.2±13.5 min, resp.; p=0.00016) and longer procedure times as well (153.1±32 versus 102±24.8 min, resp.; p=0.019). The overall long-term success was significantly different between the two groups (68.3 versus 86.7%, resp.; p=0.017). No differences were found in the lesion areas of left and right PV between the two groups (resp., p=0.61 and 0.57). There were no significant differences in procedural-related complications. Conclusion. The ADV catheter compared to the first-generation balloon allows obtaining a significantly higher success rate after a single PVI procedure during the long-term follow-up. Fluoroscopy and procedural times were significantly shortened using the ADV catheter

    The effects of gender on electrical therapies for the heart: procedural considerations, results and complications: A report from the XII Congress of the Italian Association on Arrhythmology and Cardiostimulation (AIAC)

    Get PDF
    Use of cardiac implantable devices and catheter ablation is steadily increasing in Western countries following the positive results of clinical trials. Despite the advances in scientific knowledge, tools development, and techniques improvement we still have some grey area in the field of electrical therapies for the heart. In particular, several reports highlighted differences both in medical behaviour and procedural outcomes between female and male candidates. Women are referred later for catheter ablation of supraventricular arrhythmias, especially atrial fibrillation, leading to suboptimal results. On the opposite females present greater response to cardiac resynchronization, while the benefit of implantable defibrillator in primary prevention seems to be less pronounced. Differences on aetiology, clinical profile, and development of myocardial scarring are the more plausible causes. This review will discuss all these aspects together with gender-related differences in terms of acute/late complications. We will also provide useful hints on plausible mechanisms and practical procedural aspects
    • …
    corecore