38 research outputs found

    Vitamin D Supplementation and Prevention of Type 2 Diabetes

    Get PDF
    BACKGROUND Observational studies support an association between a low blood 25-hydroxyvitamin D level and the risk of type 2 diabetes. However, whether vitamin D supplementation lowers the risk of diabetes is unknown. METHODS We randomly assigned adults who met at least two of three glycemic criteria for prediabetes (fasting plasma glucose level, 100 to 125 mg per deciliter; plasma glucose level 2 hours after a 75-g oral glucose load, 140 to 199 mg per deciliter; and glycated hemoglobin level, 5.7 to 6.4%) and no diagnostic criteria for diabetes to receive 4000 IU per day of vitamin D3 or placebo, regardless of the baseline serum 25-hydroxyvitamin D level. The primary outcome in this time-to-event analysis was new-onset diabetes, and the trial design was event-driven, with a target number of diabetes events of 508. RESULTS A total of 2423 participants underwent randomization (1211 to the vitamin D group and 1212 to the placebo group). By month 24, the mean serum 25-hydroxyvitamin D level in the vitamin D group was 54.3 ng per milliliter (from 27.7 ng per milliliter at baseline), as compared with 28.8 ng per milliliter in the placebo group (from 28.2 ng per milliliter at baseline). After a median follow-up of 2.5 years, the primary outcome of diabetes occurred in 293 participants in the vitamin D group and 323 in the placebo group (9.39 and 10.66 events per 100 person-years, respectively). The hazard ratio for vitamin D as compared with placebo was 0.88 (95% confidence interval, 0.75 to 1.04; P = 0.12). The incidence of adverse events did not differ significantly between the two groups. CONCLUSIONS Among persons at high risk for type 2 diabetes not selected for vitamin D insufficiency, vitamin D3 supplementation at a dose of 4000 IU per day did not result in a significantly lower risk of diabetes than placebo. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases and others; D2d ClinicalTrials.gov number, NCT01942694.

    Vitamin D Supplementation and Prevention of Type 2 Diabetes

    Get PDF
    BACKGROUND Observational studies support an association between a low blood 25-hydroxyvitamin D level and the risk of type 2 diabetes. However, whether vitamin D supplementation lowers the risk of diabetes is unknown. METHODS We randomly assigned adults who met at least two of three glycemic criteria for prediabetes (fasting plasma glucose level, 100 to 125 mg per deciliter; plasma glucose level 2 hours after a 75-g oral glucose load, 140 to 199 mg per deciliter; and glycated hemoglobin level, 5.7 to 6.4%) and no diagnostic criteria for diabetes to receive 4000 IU per day of vitamin D3 or placebo, regardless of the baseline serum 25-hydroxyvitamin D level. The primary outcome in this time-to-event analysis was new-onset diabetes, and the trial design was event-driven, with a target number of diabetes events of 508. RESULTS A total of 2423 participants underwent randomization (1211 to the vitamin D group and 1212 to the placebo group). By month 24, the mean serum 25-hydroxyvitamin D level in the vitamin D group was 54.3 ng per milliliter (from 27.7 ng per milliliter at baseline), as compared with 28.8 ng per milliliter in the placebo group (from 28.2 ng per milliliter at baseline). After a median follow-up of 2.5 years, the primary outcome of diabetes occurred in 293 participants in the vitamin D group and 323 in the placebo group (9.39 and 10.66 events per 100 person-years, respectively). The hazard ratio for vitamin D as compared with placebo was 0.88 (95% confidence interval, 0.75 to 1.04; P = 0.12). The incidence of adverse events did not differ significantly between the two groups. CONCLUSIONS Among persons at high risk for type 2 diabetes not selected for vitamin D insufficiency, vitamin D3 supplementation at a dose of 4000 IU per day did not result in a significantly lower risk of diabetes than placebo. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases and others; D2d ClinicalTrials.gov number, NCT01942694.

    Overview of the instrumentation for the Dark Energy Spectroscopic Instrument

    Get PDF
    The Dark Energy Spectroscopic Instrument (DESI) embarked on an ambitious 5 yr survey in 2021 May to explore the nature of dark energy with spectroscopic measurements of 40 million galaxies and quasars. DESI will determine precise redshifts and employ the baryon acoustic oscillation method to measure distances from the nearby universe to beyond redshift z > 3.5, and employ redshift space distortions to measure the growth of structure and probe potential modifications to general relativity. We describe the significant instrumentation we developed to conduct the DESI survey. This includes: a wide-field, 3.°2 diameter prime-focus corrector; a focal plane system with 5020 fiber positioners on the 0.812 m diameter, aspheric focal surface; 10 continuous, high-efficiency fiber cable bundles that connect the focal plane to the spectrographs; and 10 identical spectrographs. Each spectrograph employs a pair of dichroics to split the light into three channels that together record the light from 360–980 nm with a spectral resolution that ranges from 2000–5000. We describe the science requirements, their connection to the technical requirements, the management of the project, and interfaces between subsystems. DESI was installed at the 4 m Mayall Telescope at Kitt Peak National Observatory and has achieved all of its performance goals. Some performance highlights include an rms positioner accuracy of better than 0.″1 and a median signal-to-noise ratio of 7 of the [O ii] doublet at 8 × 10−17 erg s−1 cm−2 in 1000 s for galaxies at z = 1.4–1.6. We conclude with additional highlights from the on-sky validation and commissioning, key successes, and lessons learned

    The Law and Economics of Liability Insurance: A Theoretical and Empirical Review

    Full text link

    Reproducibility of a prediabetes classification in a contemporary population.

    No full text
    Aims: To assess whether meeting both fasting plasma glucose (FPG) and HbA1c criteria for prediabetes in people at high risk indicates with near certainty the presence of dysglycemia on repeat testing. Methods: Observational study using data from Vitamin D and Type 2 Diabetes (D2d) study. HbA1c, FPG were measured at screening visit 1; FPG, HbA1c and 2 h plasma glucose (2hPG) measured at screening visit 2 (a median of 21 days later); participants classified as having normal glucose regulation (all 3 tests in normal range), prediabetes or diabetes (at least 1 of 3 tests in diabetes range). A predictive model was developed to estimate the probability of confirming dysglycemia and for detecting diabetes at screening visit 2 based on values of FPG and HbA1c at screening visit 1. Results: Of 1271 participants who met both FPG and HbA1c criteria for prediabetes at screening visit 1, 98.6% exhibited dysglycemia (defined as prediabetes or diabetes) on repeat testing (84.5% were classified as having prediabetes, 14.1% were reclassified as having diabetes). Of those with diabetes, 62.6% were identified by 2hPG alone. Conclusions: Combined measurement of FPG and HbA1c is a reliable and reproducible measure to identify presence of dysglycemia among people at high risk. A prediction model is provided to help clinicians decide whether an oral glucose tolerance test will provide value in detecting diabetes based on the 2hPG criterion
    corecore