8 research outputs found

    Neuromarkers of anxiety and depression in a patient after neuro-ophthalmic surgery of the meningioma : effect of individually-tailored tDCS and neurofeedback

    Get PDF
    The aim of the study was to evaluate the effectiveness of individually tailored anodal tDCs/ neurofeedback protocol for the reduction of post-operative depression after a neuroophtalmological operation of the meningioma. The neuromarkers in Quantitative EEG (QEEG) and Event-related potentials (ERPs) were utilized in the construction of protocol and evaluation. [b]Case description[/b]. A 45-year-old female after successful neuro-ophthalmic surgery of the meningioma, complained of severe pain and anxiety, difficulties with sleeping, attention and memory problems, as well as inability to continue working in her given profession. Neuropsychological testing showed lack of cognitive disturbances and post-operative depression. Two working hypotheses were tested to find neuromarkers of depression and anxiety. In line with the ‘depression hypothesis’ a frontal alpha asymmetry pattern was found in the patient, and in line with the ‘anxiety’ hypothesis an increased left temporal P1 wave in response to visual stimuli was found in ERPs. A specific alpha asymmetry neurofeedback protocol combined with an anodal tDCS was suggested. Twenty sessions of individually-tailored anodal tDCs/ neurofeedback protocol were performed. The QEEG frontal asymmetry pattern and the excessive temporal P1 wave were normalized after the intervention. [b]Conclusions. [/b]The patient recovered from post-operative depression and returned to work after 20 sessions of the combined neurofeedback/tDCS protocol. Specific patterns of QEEG and ERPs serve as neuromarkers for constructing the protocol and for monitoring the results of intervention

    Neuromarkers of anxiety and depression in a patient after neuro-ophthalmic surgery of the meningioma – effect of individually-tailored tDCS and neurofeedback

    Get PDF
    The aim of the study was to evaluate the effectiveness of individually tailored anodal tDCs/ neurofeedback protocol for the reduction of post-operative depression after a neuroophtalmological operation of the meningioma. The neuromarkers in Quantitative EEG (QEEG) and Event-related potentials (ERPs) were utilized in the construction of protocol and evaluation. [b]Case description[/b]. A 45-year-old female after successful neuro-ophthalmic surgery of the meningioma, complained of severe pain and anxiety, difficulties with sleeping, attention and memory problems, as well as inability to continue working in her given profession. Neuropsychological testing showed lack of cognitive disturbances and post-operative depression. Two working hypotheses were tested to find neuromarkers of depression and anxiety. In line with the ‘depression hypothesis’ a frontal alpha asymmetry pattern was found in the patient, and in line with the ‘anxiety’ hypothesis an increased left temporal P1 wave in response to visual stimuli was found in ERPs. A specific alpha asymmetry neurofeedback protocol combined with an anodal tDCS was suggested. Twenty sessions of individually-tailored anodal tDCs/ neurofeedback protocol were performed. The QEEG frontal asymmetry pattern and the excessive temporal P1 wave were normalized after the intervention. [b]Conclusions. [/b]The patient recovered from post-operative depression and returned to work after 20 sessions of the combined neurofeedback/tDCS protocol. Specific patterns of QEEG and ERPs serve as neuromarkers for constructing the protocol and for monitoring the results of intervention

    Subcutaneous implantable cardioverter-defibrillator therapy in Poland: Results of the Polish S-ICD Registry

    Get PDF
    Background: The use of a subcutaneous implantable cardioverter-defibrillator (S-ICD) has been expanding in Poland since 2014. The Polish Registry of S-ICD Implantations was held by the Heart Rhythm Section of the Polish Cardiac Society between May 2020 and September 2022 to monitor the implementation of that therapy in Poland. Aims: To investigate and present the state-of-the-art of S-ICD implantation in Poland. Methods: Implanting centers reported clinical data of patients undergoing S-ICD implantations and replacements, including: age, gender, height, weight, underlying disease, history of pacemaker and defibrillator implantations, indications for S-ICD, electrocardiographical parameters, procedural techniques, and complications. Results: 440 patients undergoing S-ICD implantation (411) or replacement (29) were reported by 16 centers. Most patients were in New York Heart Association class II (218 patients, 53%) or I (150 patients, 36.5%). Left ventricular ejection fraction was 10-80%, median (IQR) 33% (25%‒55%). Primary prevention indications were present in 273 patients (66.4%). Non-ischemic cardiomyopathy was reported in 194 patients (47.2%). The main reason for the choice of S-ICD were: young age (309, 75.2%), risk of infective complications (46, 11.2%), prior infective endocarditis (36, 8.8%), hemodialysis (23, 5.6%), and immunosuppressive therapy (7, 1.7%). Electrocardiographic screening was performed in 90% of patients. The rate of adverse events was low (1.7%). No surgical complications were observed. Conclusions: Qualification for S-ICD in Poland was slightly different when compared to the rest of Europe. The implantation technique was mostly consistent with the current guidelines. S-ICD implantation was safe, and the complication rate was low

    Utilization of subcutaneous cardioverter-defibrillator in Poland and Europe : comparison of the results of multi-center registries

    No full text
    The implantation of a subcutaneous cardioverter-defibrillator (S-ICD) may be used instead of a traditional transvenous system to prevent sudden cardiac death. Our aim was to compare the characteristics of S-ICD patients from the multi-center registry of S-ICD implantations in Poland with the published results of the European Snapshot Survey on S-ICD Implantation (ESSS-SICDI). We compared data of 137 Polish S-ICD patients with 68 patients from the ESSS-SICDI registry. The groups did not differ significantly in terms of sex, prevalence of ischemic cardiomyopathy, concomitant diseases, and the rate of primary prevention indication. Polish patients had more advanced heart failure (New York Heart Association (NYHA) class III: 11.7% vs. 2.9%, NYHA II: 48.9% vs. 29.4%, NYHA I: 39.4% vs. 67.7%, p < 0.05 each). Young age (75.9% vs. 50%, p < 0.05) and no vascular access (7.3% vs. 0%, p < 0.05) were more often indications for S-ICD. The percentage of patients after transvenous system removal due to infections was significantly higher in the Polish group (11% vs. 1.5%, p < 0.05). In the European population, S-ICD was more frequently chosen because of patients’ active lifestyle and patients’ preference (both 10.3% vs. 0%, p < 0.05). Our analysis shows that in Poland, compared to other European countries, subcutaneous cardioverters-defibrillators are being implanted in patients at a more advanced stage of chronic heart failure. The most frequent reason for choosing a subcutaneous system instead of a transvenous ICD is the young age of a patient
    corecore