41 research outputs found

    Selective scattering between Floquet-Bloch and Volkov states in a topological insulator

    Get PDF
    The coherent optical manipulation of solids is emerging as a promising way to engineer novel quantum states of matter. The strong time periodic potential of intense laser light can be used to generate hybrid photon-electron states. Interaction of light with Bloch states leads to Floquet-Bloch states which are essential in realizing new photo-induced quantum phases. Similarly, dressing of free electron states near the surface of a solid generates Volkov states which are used to study non-linear optics in atoms and semiconductors. The interaction of these two dynamic states with each other remains an open experimental problem. Here we use Time and Angle Resolved Photoemission Spectroscopy (Tr-ARPES) to selectively study the transition between these two states on the surface of the topological insulator Bi2Se3. We find that the coupling between the two strongly depends on the electron momentum, providing a route to enhance or inhibit it. Moreover, by controlling the light polarization we can negate Volkov states in order to generate pure Floquet-Bloch states. This work establishes a systematic path for the coherent manipulation of solids via light-matter interaction.Comment: 21 pages, 6 figures, final version to appear in Nature Physic

    A tabletop x-ray tomography instrument for nanometer-scale imaging: demonstration of the 1,000-element transition-edge sensor subarray

    Full text link
    We report on the 1,000-element transition-edge sensor (TES) x-ray spectrometer implementation of the TOMographic Circuit Analysis Tool (TOMCAT). TOMCAT combines a high spatial resolution scanning electron microscope (SEM) with a highly efficient and pixelated TES spectrometer to reconstruct three-dimensional maps of nanoscale integrated circuits (ICs). A 240-pixel prototype spectrometer was recently used to reconstruct ICs at the 130 nm technology node, but to increase imaging speed to more practical levels, the detector efficiency needs to be improved. For this reason, we are building a spectrometer that will eventually contain 3,000 TES microcalorimeters read out with microwave superconducting quantum interference device (SQUID) multiplexing, and we currently have commissioned a 1,000 TES subarray. This still represents a significant improvement from the 240-pixel system and allows us to begin characterizing the full spectrometer performance. Of the 992 maximimum available readout channels, we have yielded 818 devices, representing the largest number of TES x-ray microcalorimeters simultaneously read out to date. These microcalorimeters have been optimized for pulse speed rather than purely energy resolution, and we measure a FWHM energy resolution of 14 eV at the 8.0 keV Cu Kα\alpha line.Comment: 5 pages, 4 figures, submitted to IEEE Transactions on Applied Superconductivit

    Laser-assisted photoemission from surfaces

    No full text

    Laser plasma x-ray source for ultrafast time-resolved x-ray absorption spectroscopy

    No full text
    We describe a laser-driven x-ray plasma source designed for ultrafast x-ray absorption spectroscopy. The source is comprised of a 1 kHz, 20 W, femtosecond pulsed infrared laser and a water target. We present the x-ray spectra as a function of laser energy and pulse duration. Additionally, we investigate the plasma temperature and photon flux as we vary the laser energy. We obtain a 75 mu m FWHM x-ray spot size, containing similar to 10(6) photons/s, by focusing the produced x-rays with a polycapillary optic. Since the acquisition of x-ray absorption spectra requires the averaging of measurements from >10(7) laser pulses, we also present data on the source stability, including single pulse measurements of the x-ray yield and the x-ray spectral shape. In single pulse measurements, the x-ray flux has a measured standard deviation of 8%, where the laser pointing is the main cause of variability. Further, we show that the variability in x-ray spectral shape from single pulses is low, thus justifying the combining of x-rays obtained from different laser pulses into a single spectrum. Finally, we show a static x-ray absorption spectrum of a ferrioxalate solution as detected by a microcalorimeter array. Altogether, our results demonstrate that this water-jet based plasma source is a suitable candidate for laboratory-based time-resolved x-ray absorption spectroscopy experiments. (C) 2015 Author(s)

    Direct Mapping of Hot-Electron Relaxation and Multiplication Dynamics in PbSe Quantum Dots

    No full text
    How hot electrons relax in semiconductor quantum dots is of critical importance to many potential applications, such as solar energy conversion, light emission, and photon detection. A quantitative answer to this question has not been possible due in part to limitations of current experimental techniques in probing hot electron populations. Here we use femtosecond time-resolved two-photon photoemission spectroscopy to carry out a complete mapping in time- and energy-domains of hot electron relaxation and multiexciton generation (MEG) dynamics in lead selenide quantum dots functionalized with 1,2-ethanedithiols. We find a linear scaling law between the hot electron relaxation rate and its energy above the conduction band minimum. There is no evidence of MEG from intraband hot electron relaxation for excitation photon energy as high as three times the bandgap (3<i>E</i><sub>g</sub>). Rather, MEG occurs in this system only from interband hot electron transitions at sufficiently high photon energies (∼4<i>E</i><sub>g</sub>)
    corecore