217 research outputs found

    THE ASSOCIATION BETWEEN PARTNERS' EXPRESSED EMOTION AND DEPRESSION:MEDIATED BY PATIENTS' DYSFUNCTIONAL ATTITUDES?

    Get PDF
    The respective roles of expressed emotion and dysfunctional cognitive processes are well documented in depression, but their interplay has seldom been given attention. We examined the patients' and partners' expressed emotion (EE) and dysfunctional attitudes in predicting depressive symptoms in a sample of N = 63 couples with one clinically-depressed partner (37 females and 26 males). Partners' EE played a more important role for patients' dysfunctional attitudes and their depressive symptoms; nondepressed partners' dysfunctional attitudes and depressive symptoms were unaffected by patients' EE. In contrasting two models that predict self-reported and clinician-rated depression, we found more support for dysfunctional attitudes serving as a mediator rather than a moderator for the association between partners' EE and patients' depressive symptoms. Partners' criticism may play a role worthy of more attention in depressed patients' dysfunctional attitudes and maintenance of their depres

    The Phantom Urine: An Unexpected Finding during a Routine Cesarean Section.

    Get PDF
    We present here an atypical finding during an elective repeat cesarean section. Despite urine flow through an indwelling bladder catheter, bladder remains distended during the whole procedure. Unexpected anatomical variations and malformations can make routine surgery challenging. Urinary tract anomalies should be suspected in cases of unexpected difficult bladder catheterization

    Dense breast on screening mammography: utility and futility of additional ultrasound.

    Get PDF
    High breast density decreases the sensitivity of mammography. Regardless of masking effect, it is also a stronger predictor for breast cancer than most other risk factors, including family history. Up to 50% of women have dense breast (categories C+D). The relative risk is 2.1 to 2.3 in women with extremely dense breast (category d). There is little consensus on the potential need of additional measures. Breast Ultrasound (US) may be proposed as an adjunctive test, as it is non-invasive and non-irradiating. Since 2012, our program for breast cancer screening propose to realise an additional US to the women with category d breasts. An evaluation of the data of the first year showed that less 50% of the women act upon the recommendation. In spite of the low compliance supplementary cancers were found. Since, no more evaluation was performed. The aim of this study was: To evaluate the effect of the recommendation in term of additional cancer's identification, additional biopsies and additional investigations. To identify the reasons of non compliance

    Forensic image analysis – CCTV distortion and artefacts

    Get PDF
    © 2018 Elsevier B.V. As a result of the worldwide deployment of surveillance cameras, authorities have gained a powerful tool that captures footage of activities of people in public areas. Surveillance cameras allow continuous monitoring of the area and allow footage to be obtained for later use, if a criminal or other act of interest occurs. Following this, a forensic practitioner, or expert witness can be required to analyse the footage of the Person of Interest. The examination ultimately aims at evaluating the strength of evidence at source and activity levels. In this paper, both source and activity levels are inferred from the trace, obtained in the form of CCTV footage. The source level alludes to features observed within the anatomy and gait of an individual, whilst the activity level relates to activity undertaken by the individual within the footage. The strength of evidence depends on the value of the information recorded, where the activity level is robust, yet source level requires further development. It is therefore suggested that the camera and the associated distortions should be assessed first and foremost and, where possible, quantified, to determine the level of each type of distortion present within the footage. A review of the ‘forensic image analysis’ review is presented here. It will outline the image distortion types and detail the limitations of differing surveillance camera systems. The aim is to highlight various types of distortion present particularly from surveillance footage, as well as address gaps in current literature in relation to assessment of CCTV distortions in tandem with gait analysis. Future work will consider the anatomical assessment from surveillance footage

    Forensic gait analysis — Morphometric assessment from surveillance footage

    Get PDF
    © 2019 Elsevier B.V. Following the technological rise of surveillance cameras and their subsequent proliferation in public places, the use of information gathered by such means for investigative and evaluative purposes sparked a large interest in the forensic community and within policing scenarios. In particular, it is suggested that analysis of the body, especially the assessment of gait characteristics, can provide useful information to aid the investigation. This paper discusses the influences upon gait to mitigate some of the limitations of surveillance footage, including those due to the varying anatomical differences between individuals. Furthermore, the differences between various techniques applied to assess gait are discussed, including biometric gait recognition, forensic gait analysis, tracking technology, and marker technology. This review article discusses the limitations of the current methods for assessment of gait; exposing gaps within the literature in regard to various influences impacting upon the gait cycle. Furthermore, it suggests a ‘morphometric’ technique to enhance the available procedures to potentially facilitate the development of standardised protocols with supporting statistics and database. This in turn will provide meaningful information to forensic investigation, intelligence-gathering processes, and potentially as an additional method of forensic evaluation of evidence

    MHC-correlated preferences in diestrous female horses (Equus caballus).

    Get PDF
    Genes of the major histocompatibility complex (MHC) have been shown to influence communication in many vertebrates, possibly with context-specific MHC-correlated reactions. Here we test for MHC-linked female preferences in the polygynous horse (Equus caballus) by repeatedly exposing 19 mares to a group of seven sexually experienced stallions. Each mare was tested four times during two consecutive reproductive cycles, twice during estrus and twice during diestrus. Male plasma testosterone concentrations were determined from weekly blood samples, and equine leukocyte antigen (ELA) class I and II alleles were determined serologically at the end of the experiments. Perception of male attractiveness was strongly dependent on estrous cycle: mean preference scores did not correlate for mares in diestrus and estrus and varied more during estrus than during diestrus. We found elevated female interests for MHC-dissimilar stallions, but only during diestrus, not during estrus. Female preferences were not significantly predicted by mean male testosterone plasma concentrations. However, testosterone concentrations changed during the 11 weeks of the experiment. By the end of the experiment, average testosterone concentration was significantly correlated to the average number of MHC alleles the stallions shared with the mares. We conclude that the MHC affects female preferences for stallions, but non-MHC linked male characteristics can overshadow effects of the MHC during estrus

    Pulse Oximetry as an Aid to Rule Out Pneumonia among Patients with a Lower Respiratory Tract Infection in Primary Care.

    Get PDF
    Guidelines recommend chest X-rays (CXRs) to diagnose pneumonia and guide antibiotic treatment. This study aimed to identify clinical predictors of pneumonia that are visible on a chest X-ray (CXR+) which could support ruling out pneumonia and avoiding unnecessary CXRs, including oxygen saturation. A secondary analysis was performed in a clinical trial that included patients with suspected pneumonia in Swiss primary care. CXRs were reviewed by two radiologists. We evaluated the association between clinical signs (heart rate > 100/min, respiratory rate ≥ 24/min, temperature ≥ 37.8 °C, abnormal auscultation, and oxygen saturation < 95%) and CXR+ using multivariate analysis. We also calculated the diagnostic performance of the associated clinical signs combined in a clinical decision rule (CDR), as well as a CDR derived from a large meta-analysis (at least one of the following: heart rate > 100/min, respiratory rate ≥ 24/min, temperature ≥ 37.8 °C, or abnormal auscultation). Out of 469 patients from the initial trial, 107 had a CXR and were included in this study. Of these, 26 (24%) had a CXR+. We found that temperature and oxygen saturation were associated with CXR+. A CDR based on the presence of either temperature ≥ 37.8 °C and/or an oxygen saturation level < 95% had a sensitivity of 69% and a negative likelihood ratio (LR-) of 0.45. The CDR from the meta-analysis had a sensitivity of 92% and an LR- of 0.37. The addition of saturation < 95% to this CDR increased the sensitivity (96%) and decreased the LR- (0.21). In conclusion, this study suggests that pulse oximetry could be added to a simple CDR to decrease the probability of pneumonia to an acceptable level and avoid unnecessary CXRs

    Permutationally Invariant, Reproducing Kernel-Based Potential Energy Surfaces for Polyatomic Molecules: From Formaldehyde to Acetone

    Full text link
    Constructing accurate, high dimensional molecular potential energy surfaces (PESs) for polyatomic molecules is challenging. Reproducing Kernel Hilbert space (RKHS) interpolation is an efficient way to construct such PESs. However, the scheme is most effective when the input energies are available on a regular grid. Thus the number of reference energies required can become very large even for penta-atomic systems making such an approach computationally prohibitive when using high-level electronic structure calculations. Here an efficient and robust scheme is presented to overcome these limitations and is applied to constructing high dimensional PESs for systems with up to 10 atoms. Using energies as well as gradients reduces the number of input data required and thus keeps the number of coefficients at a manageable size. Correct implementation of permutational symmetry in the kernel products is tested and explicitly demonstrated for the highly symmetric CH4_4 molecule.Comment: 40 pages, 13 Figure

    Diagnostic performance of MRI for detection of intestinal fistulas in patients with complicated inflammatory bowel conditions

    Get PDF
    The diagnostic performance of magnetic resonance imaging (MRI) for detection of intestinal fistulas, other than perianal, in patients with known complicated inflammatory bowel conditions (CIBC) was investigated. Our study group consisted of 20 patients (12 women, mean age 43years) with CIBC, including Crohn's disease (n=13), colonic diverticulitis (n=3), colitis after radiotherapy (n=3) and of postoperative origin (n=1). Eleven surgically proven enteral fistulas were known in ten (50%) of these patients, being of enterovesical (n=3), enterocolic (n=2), enteroenteral (n=2), rectovaginal (n=2), rectovaginovesical (n=1) and of entercutaneous (n=1) localisation. The other ten patients (50%), used as the control group, showed MR features of CIBC, although without any fistulous tract. Multiplanar T1- and T2-weighted sequences had been performed, including gadolinium-enhanced acquisition with fat saturation (1.5T). MR findings were independently blindly and retrospectively reviewed by three radiologists for the presence and etiology of any fistula, as well as visualization and characterization of the fistulous tract. Results were compared with surgical findings (n=16) and clinical evolution (n=4). Interobserver agreement was calculated. Interobserver agreement kappa for fistula detection was 0.71. Overall sensitivity, specificity and accuracy for fistula detection were 78.6%, 75% and 77.2%, respectively. Sensitivity for fistula characterization was 80.6%, with visualization of the fistulous tract in all cases, whereby T1-weighted gadolinium-enhanced fat-saturated images were considered the most useful sequences. Gadolinium-enhanced MRI is a reliable and reproducible tool for detection of enteral fistulas secondary to inflammatory condition
    corecore