1,469 research outputs found

    Determination of regional bone blood flow by means of fluorescent microspheres using an automated sample-processing procedure

    Get PDF
    The determination of regional blood flow utilizing fluorescent microspheres (FMs) is an established method for numerous organs. Recent progress, in particular the automation of sample processing, has further improved this method. However, the FM method (reference sample technique), which allows repetitive measurement of regional organ blood flow, has so far not been used for the determination of blood flow in bone. The aim of the present study was to establish FM for the quantification of regional bone blood flow (RBBF). Female, anesthetized New Zealand rabbits (n = 6) received left ventricular injections of different amounts of FM at six subsequent time points. In order to examine the precision of RBBF determination, two different FM species were injected simultaneously at the sixth injection. At the end of the experiments the femoral and tibial condyles of each hind limb were removed and the fluorescence intensity in the tissue samples was measured by an automated procedure. In an in vitro study we have shown that acid digestion of the crystalline matrix has no effect on the fluorescence characteristics of FM. The determination of the number of spheres per tissue sample revealed that depending on the tissue sample size up to 3 x 10(6) spheres/injection were necessary to obtain about 400 microspheres in the individual bone samples. RBBF values of the tibial and femoral condyles did not differ at various injection intervals. The tibial blood flow values varied between 6.6 +/- 1.1 and 8.5 +/- 1.4 ml/min/100 g and were significantly higher than those of the femur (4.3 +/- 1.1 to 6.0 +/- 1.8 ml/min/100 g). The bone blood flow values obtained by simultaneous injection of two FM species correlated significantly (r = 0.96, slope = 1.06, intercept = 0.05), the mean difference was 0.39 +/- 1.11 ml/min/100 g. Our data demonstrate that the measurement of RBBF by means of FM allows a valid determination of RBBF. Copyright (C) 2003 S. Karger AG, Basel

    Woodpeckers

    Get PDF
    WL-915; Integrated Pest Management, Cooperative Extension Service, North Dakota State University : In cooperation with U.S. Dept. of Agriculture-APHIS Animal Damage Control, 1986

    Bats

    Get PDF

    Comparison of regional blood flow values measured by radioactive and fluorescent microspheres

    Get PDF
    Fluorescent microspheres (FM) have become an attractive alternative to radioactive microspheres (RM) for the measurement of regional blood flow (RBF). The aim of the present study was to investigate the comparability of both methods by measuring RBF with FM and RM. Eight anaesthetised pigs received simultaneous, left atrial injections of FM and RM with a diameter of 15 mum at six different time points. Blood reference samples were collected from the descending aorta. RBF was determined in tissue samples of the myocardium, spleen and kidneys of all 8 animals. After radioactivity of the tissue samples was determined, the samples were processed automatically for measuring fluorescence using a recently developed filter device (SPU). RBF was calculated with both the isotope and spectrometric data of both methods for each sample resulting in a total of 10,512 blood flow values. The comparison of the RBF values yielded high linear correlation (mean r(2) = 0.95 +/- 0.03 to 0.97 +/- 0.02) and excellent agreement (bias 5.4-6.7%, precision 9.9-16.5%) of both methods. Our results indicate the validity of MS and of the automated tissue processing technique by means of the SPU. Copyright (C) 2002 S. Karger AG, Basel

    Islets of Langerhans Are Protected from Inflammatory Cell Recruitment during Reperfusion of Rat Pancreas Grafts

    Get PDF
    Background: Ischemia/reperfusion (I/R) injury plays a pivotal role in the development of graft pancreatitis, with ischemia time representing one of its crucial factors. However, it is unclear, whether exocrine and endocrine tissue experience similar inflammatory responses during pancreas transplantation (PTx). This study evaluated inflammatory susceptibilities of islets of Langerhans (ILH) and exocrine tissue after different preservation periods during early reperfusion. Methods: PTx was performed in rats following 2 h (2h-I) or 18 h (18h-I) preservation. Leukocyte-endothelial cell interactions (LEI) were analyzed in venules of acinar tissue and ILH in vivo over 2 h reperfusion. Nontransplanted animals served as controls. Tissue samples were analyzed by histomorphometry. Results: In exocrine venules leukocyte rolling predominated in the 2h-I group. In the 18h-I group, additionally, high numbers of adherent leukocytes were found. Histology revealed significant edema formation and leukocyte extravasation in the 18h-I group. Notably, LEI in postcapillary venules of ILH were significantly lower. Leukocyte rolling was only moderately enhanced and few leukocytes were found adherent. Histology revealed minor leukocyte extravasation. Conclusion: Ischemia time contributes decisively to the extent of the I/R-injury in PTx. However, ILH have a significantly lower susceptibility towards I/R, even when inflammatory reactions in adjacent exocrine tissue are evident. Copyright (C) 2010 S. Karger AG, Base

    Greater sage- grouse ecology in Western Box Elder County, Utah.

    Get PDF

    A portable platform for accelerated PIC codes and its application to GPUs using OpenACC

    Get PDF
    We present a portable platform, called PIC_ENGINE, for accelerating Particle-In-Cell (PIC) codes on heterogeneous many-core architectures such as Graphic Processing Units (GPUs). The aim of this development is efficient simulations on future exascale systems by allowing different parallelization strategies depending on the application problem and the specific architecture. To this end, this platform contains the basic steps of the PIC algorithm and has been designed as a test bed for different algorithmic options and data structures. Among the architectures that this engine can explore, particular attention is given here to systems equipped with GPUs. The study demonstrates that our portable PIC implementation based on the OpenACC programming model can achieve performance closely matching theoretical predictions. Using the Cray XC30 system, Piz Daint, at the Swiss National Supercomputing Centre (CSCS), we show that PIC_ENGINE running on an NVIDIA Kepler K20X GPU can outperform the one on an Intel Sandybridge 8-core CPU by a factor of 3.4

    Exclusionary methods to reduce predation on ground nesting birds and their nests

    Get PDF

    On particle acceleration and trapping by Poynting flux dominated flows

    Full text link
    Using particle-in-cell (PIC) simulations, we study the evolution of a strongly magnetized plasma slab propagating into a finite density ambient medium. Like previous work, we find that the slab breaks into discrete magnetic pulses. The subsequent evolution is consistent with diamagnetic relativistic pulse acceleration of \cite{liangetal2003}. Unlike previous work, we use the actual electron to proton mass ratio and focus on understanding trapping vs. transmission of the ambient plasma by the pulses and on the particle acceleration spectra. We find that the accelerated electron distribution internal to the slab develops a double-power law. We predict that emission from reflected/trapped external electrons will peak after that of the internal electrons. We also find that the thin discrete pulses trap ambient electrons but allow protons to pass through, resulting in less drag on the pulse than in the case of trapping of both species. Poynting flux dominated scenarios have been proposed as the driver of relativistic outflows and particle acceleration in the most powerful astrophysical jets.Comment: 25 pages, Accepted by Plasma Physics and Controlled Fusio
    • …
    corecore