21 research outputs found
Safety and efficacy of a multi-electrode renal sympathetic denervation system in resistant hypertension: The EnligHTN I trial
Aims: Catheter-based renal artery sympathetic denervation has emerged as a novel therapy for treatment of patients with drug-resistant hypertension. Initial studies were performed using a single electrode radiofrequency catheter, but recent advances in catheter design have allowed the development of multi-electrode systems that can deliver lesions with a pre-determined pattern. This study was designed to evaluate the safety and efficacy of the EnligHTN ™ multi-electrode system. Methods and results: We conducted the first-in-human, prospective, multi-centre, non-randomized study in 46 patients (67% male, mean age 60 years, and mean baseline office blood pressure 176/96 mmHg) with drug-resistant hypertension. The primary efficacy objective was change in office blood pressure from baseline to 6 months. Safety measures included all adverse events with a focus on the renal artery and other vascular complications and changes in renal function. Renal artery denervation, using the EnligHTN™ system significantly reduced the office blood pressure from baseline to 1, 3, and 6 months by -28/10, -27/10 and -26/10 mmHg, respectively (P < 0.0001). No acute renal artery injury or other serious vascular complications occurred. Small, non-clinically relevant, changes in average estimated glomerular filtration rate were reported from baseline (87 ± 19 mL/min/1.73 m2) to 6 months post-procedure (82 ± 20 mL/min/1.73 m2). Conclusion: Renal sympathetic denervation, using the EnligHTN™ multi-electrode catheter results in a rapid and significant office blood pressure reduction that was sustained through 6 months. The EnligHTN™ system delivers a promising therapy for the treatment of drug-resistant hypertension. © The Author 2013
Quantitative and qualitative coronary plaque assessment using computed tomography coronary angiography: a comparison with intravascular ultrasound
BACKGROUND:To compare computed tomography coronary angiography (CTCA) with intravascular ultrasound (IVUS) in quantitative and qualitative plaque assessment. METHODS:Patients who underwent IVUS and CTCA within 3 months for suspected coronary artery disease were retrospectively studied. Plaque volumes on CTCA were quantified manually and with automated-software and were compared to IVUS. High-risk plaque features were compared between CTCA and IVUS. RESULTS:There were 769 slices in 32 vessels (27 patients). Manual plaque quantification on CTCA was comparable to IVUS per slice (mean difference of 0.06±0.07, p=0.44; Bland-Altman 95% limits of agreement -2.19-2.08 mm3, bias of -0.06mm3) and per vessel (3.1mm3 ± -2.85mm3, p=0.92). In contrast, there was significant difference between automated-software and IVUS per slice (2.3±0.09mm3, p<0.001; 95% LoA -6.78 to 2.25mm3, bias of -2.2mm3) and per vessel (33.04±10.3 mm3, p<0.01). The sensitivity, specificity, positive and negative predictive value of CTCA to detect plaques that had features of echo-attenuation on IVUS was 93.3%, 99.6%, 93.3% and 99.6% respectively. The association of ≥2 high-risk plaque features on CTCA with echo attenuation (EA) plaque features on IVUS was excellent (86.7%, 99.6%, 92.9% and 99.2%). In comparison, the association of high-risk plaque features on CTCA and plaques with echo-lucency on IVUS was only modest. CONCLUSION:Plaque volume quantification by manual CTCA method is accurate when compared to IVUS. The presence of at least two high-risk plaque features on CTCA is associated with plaque features of echo attenuation on IVUS.Ravi Kiran Munnur, Jordan Andrews ... Peter Psaltis ... Stephen Nicholls ... Jordan Andrews ... Yu Kataoka ... et al
Catheter-based renal denervation for resistant hypertension: Twenty-four month results of the EnligHTN™ i first-in-human study using a multi-electrode ablation system
Background Long term safety and efficacy data of multi-electrode ablation system for renal denervation (RDN) in patients with drug resistant hypertension (dRHT) are limited. Methods and results We studied 46 patients (age: 60 ± 10 years, 4.7 ± 1.0 antihypertensive drugs) with drug resistant hypertension (dRHT). Reduction in office BP at 24 months from baseline was - 29/- 13 mm Hg, while the reduction in 24-hour ambulatory BP and in home BP at 24 months were - 13/- 7 mm Hg and - 11/- 6 mm Hg respectively (p &lt; 0.05 for all). A correlation analysis revealed that baseline office and ambulatory BP were related to the extent of office and ambulatory BP drop. Apart from higher body mass index (33.3 ± 4.7 vs 29.5 ± 6.2 kg/m2, p &lt; 0.05), there were no differences in patients that were RDN responders defined as ≥ 10 mm Hg decrease (74%, n = 34) compared to non-responders. Stepwise logistic regression analysis revealed no prognosticators of RDN response (p = NS for all). At 24 months there were no new serious device or procedure related adverse events. Conclusions The EnligHTN I study shows that the multi-electrode ablation system provides a safe method of RDN in dRHT accompanied by a clinically relevant and sustained BP reduction. © 2015 Elsevier Ireland Ltd
A prospective, randomized evaluation of a novel everolimus-eluting coronary stent: the PLATINUM (a Prosprective, Randomized, Multicenter Trial to Assess an Everolimus-Eluting Coronary Stent System (PROMUS Element) for the treatment of up to two de Novo coronary artery lesions) Trial
ObjectivesWe sought to evaluate the clinical outcomes with a novel platinum chromium everolimus-eluting stent (PtCr-EES) compared with a predicate cobalt chromium everolimus-eluting stent (CoCr-EES) in patients undergoing percutaneous coronary intervention (PCI).BackgroundRandomized trials have demonstrated an excellent safety and efficacy profile for the CoCr-EES. The PtCr-EES uses the identical antiproliferative agent and polymer but with a novel platinum chromium scaffold designed for enhanced deliverability, vessel conformability, side-branch access, radiopacity, radial strength, and fracture resistance.MethodsA total of 1,530 patients undergoing PCI of 1 or 2 de novo native lesions were randomized at 132 worldwide sites to CoCr-EES (n = 762) or PtCr-EES (n = 768). The primary endpoint was the 12-month rate of target lesion failure (TLF), the composite of target vessel-related cardiac death, target vessel-related myocardial infarction (MI), or ischemia-driven target lesion revascularization (TLR) in the per-protocol population (patients who received ?1 assigned study stent), powered for noninferiority.ResultsThe 12-month rate of TLF in the per-protocol population occurred in 2.9% versus 3.4% of patients assigned to CoCr-EES versus PtCr-EES, respectively (difference: 0.5%, 95% confidence interval: ?1.3% to 2.3%, pnoninferiority = 0.001, psuperiority = 0.60). By intention-to-treat, there were no significant differences between CoCr-EES and PtCr-EES in the 12-month rates of TLF (3.2% vs. 3.5%, p = 0.72), cardiac death or MI (2.5% vs. 2.0%, p = 0.56), TLR (1.9% vs. 1.9%, p = 0.96), or Academic Research Consortium definite or probable stent thrombosis (0.4% vs. 0.4%, p = 1.00).ConclusionsIn this large-scale, prospective, single-blind randomized trial, a novel PtCr-EES was noninferior to the predicate CoCr-EES for TLF, with nonsignificant differences in measures of safety and efficacy through 12-month follow-up after PCI. (A Prospective, Randomized, Multicenter Trial to Assess an Everolimus-Eluting Coronary Stent System [PROMUS Element] for the Treatment of up to Two De Novo Coronary Artery Lesions: NCT00823212)<br/
Recommended from our members
Evaluation of carbonyl sulfide biosphere exchange in the Simple Biosphere Model (SiB4)
The uptake of carbonyl sulfide (COS) by terrestrial plants is linked to photosynthetic uptake of CO2 as these gases partly share the same uptake pathway. Applying COS as a photosynthesis tracer in models requires an accurate representation of biosphere COS fluxes, but these models have not been extensively evaluated against field observations of COS fluxes. In this paper, the COS flux as simulated by the Simple Biosphere Model, version 4 (SiB4), is updated with the latest mechanistic insights and evaluated with site observations from different biomes: one evergreen needleleaf forest, two deciduous broadleaf forests, three grasslands, and two crop fields spread over Europe and North America. We improved SiB4 in several ways to improve its representation of COS. To account for the effect of atmospheric COS mole fractions on COS biosphere uptake, we replaced the fixed atmospheric COS mole fraction boundary condition originally used in SiB4 with spatially and temporally varying COS mole fraction fields. Seasonal amplitudes of COS mole fractions are ∼50-200 ppt at the investigated sites with a minimum mole fraction in the late growing season. Incorporating seasonal variability into the model reduces COS uptake rates in the late growing season, allowing better agreement with observations. We also replaced the empirical soil COS uptake model in SiB4 with a mechanistic model that represents both uptake and production of COS in soils, which improves the match with observations over agricultural fields and fertilized grassland soils. The improved version of SiB4 was capable of simulating the diurnal and seasonal variation in COS fluxes in the boreal, temperate, and Mediterranean region. Nonetheless, the daytime vegetation COS flux is underestimated on average by 8±27 %, albeit with large variability across sites. On a global scale, our model modifications decreased the modeled COS terrestrial biosphere sink from 922 GgSyr-1 in the original SiB4 to 753 GgSyr-1 in the updated version. The largest decrease in fluxes was driven by lower atmospheric COS mole fractions over regions with high productivity, which highlights the importance of accounting for variations in atmospheric COS mole fractions. The change to a different soil model, on the other hand, had a relatively small effect on the global biosphere COS sink. The secondary role of the modeled soil component in the global COS budget supports the use of COS as a global photosynthesis tracer. A more accurate representation of COS uptake in SiB4 should allow for improved application of atmospheric COS as a tracer of local-to global-scale terrestrial photosynthesis. © 2021 Linda M. J. Kooijmans et al.Open access journalThis item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at [email protected]