7 research outputs found

    Reliable Optical Pump Architecture for Highly Coherent Lasers Used in Space Metrology Applications

    Get PDF
    The design and initial demonstration of a laser pump module (LPM) incorporating single-mode, grating-stabilized 808-nm diode lasers and a low-loss, high-port-count optical combiner are completed. The purpose of the developed LPM is to reliably pump an Nd:YAG crystal in the laser head (LH), which serves as the optical metrology source for SIMLite mission. Using the narrow-linewidth, single-mode laser diodes enables placement of the pump power near Nd adsorption peak, which enhances pumping efficiency. Grating stabilization allows for stable pump spectra as diode operating temperature and bias current change. The low-loss, high-port-count optical combiner enables efficient combining of tens of pumps. Overall, the module supports 5+ years of continuous operation at 2 W of pump power with reliability approaching 100 percent. The LPM consists of a laser diode farm (LDF) and a pump beam combiner (PBC). An array of 807- to 808-nm fiber-pigtailed laser diodes makes up the LDF. A Bragg grating in each 5- m core single-mode (SM) fiber pigtail acts to stabilize the lasing spectra over a range of diode operating conditions. These commercially available single-mode laser diodes can deliver up to 150 mW of optical power. The outputs from the multiple pumps in the LDF are routed to the PBC, which is a 37-input by 1-output all-fiber device. The input ports consist of 5- m core SM fiber, while the output port consists of 105- m core, 0.15 NA (numerical aperture) multi-mode (MM) fiber. The combiner is fabricated by fusing the 37 input fibers while simultaneously tapering the fused region. At the completion of this process, the MM fiber is spliced to the end of the adiabatic taper, and, for protection, the combiner is sheathed by a capillary tube. A compact and robust metal housing was designed and fabricated to protect the PBC during space deployment

    Focal Plane Alignment Utilizing Optical CMM

    Get PDF
    In many applications, an optical detector has to be located relative to mechanical reference points. One solution is to specify stringent requirements on (1) mounting the optical detector relative to the chip carrier, (2) soldering the chip carrier onto the printed circuit board (PCB), and (3) installing the PCB to the mechanical structure of the subsystem. Figure 1 shows a sketch of an optical detector mounted relative to mechanical reference with high positional accuracy. The optical detector is typically a fragile wafer that cannot be physically touched by any measurement tool. An optical coordinate measuring machine (CMM) can be used to position optical detectors relative to mechanical reference points. This approach will eliminate all requirements on positional tolerances. The only requirement is that the PCB is manufactured with oversized holes. An exaggerated sketch of this situation is shown in Figure 2. The sketch shows very loose tolerances on mounting the optical detector in the chip carrier, loose tolerance on soldering the chip carrier to the PCB, and finally large tolerance on where the mounting screws are located. The PCB is held with large screws and oversized holes. The PCB is mounted loosely so it can move freely around. The optical CMM measures the mechanical reference points. Based on these measurements, the required positions of the optical detector corners can be calculated. The optical CMM is commanded to go to the position where one detector corner is supposed to be. This is indicated with the cross-hairs in Figure 2(a). This figure is representative of the image of the optical CMM monitor. Using a suitable tapping tool, the PCB is manually tapped around until the corner of the optical detector is at the crosshairs of the optical CMM. The CMM is commanded to another corner, and the process is repeated a number of times until all corners of the optical detector are within a distance of 10 to 30 microns of the required position. The situation is sketched in Figure 2(b) (the figure also shows the tapping tool and where to tap). At this point the fasteners for the PCB are torqued slightly so the PCB can still move. The PCB location is adjusted again with the tapping tool. This process is repeated 3 to 4 times until the final torque is achieved. The oversized mounting holes are then filled with a liquid bonding agent to secure the board in position (not shown in the sketch). A 10- to 30-micron mounting accuracy has been achieved utilizing this method.

    PIXL: Planetary Instrument for X-Ray Lithochemistry

    No full text
    Planetary Instrument for X-ray Lithochemistry (PIXL) is a micro-focus X-ray fluorescence spectrometer mounted on the robotic arm of NASA’s Perseverance rover. PIXL will acquire high spatial resolution observations of rock and soil chemistry, rapidly analyzing the elemental chemistry of a target surface. In 10 seconds, PIXL can use its powerful 120 μm-diameter X-ray beam to analyze a single, sand-sized grain with enough sensitivity to detect major and minor rock-forming elements, as well as many trace elements. Over a period of several hours, PIXL can autonomously raster-scan an area of the rock surface and acquire a hyperspectral map comprised of several thousand individual measured points. When correlated to a visual image acquired by PIXL’s camera, these maps reveal the distribution and abundance variations of chemical elements making up the rock, tied accurately to the physical texture and structure of the rock, at a scale comparable to a 10X magnifying geological hand lens. The many thousands of spectra in these postage stamp-sized elemental maps may be analyzed individually or summed together to create a bulk rock analysis, or subsets of spectra may be summed, quantified, analyzed, and compared using PIXLISE data analysis software. This hand lens-scale view of the petrology and geochemistry of materials at the Perseverance landing site will provide a valuable link between the larger, centimeter- to meter-scale observations by Mastcam-Z, RIMFAX and Supercam, and the much smaller (micron-scale) measurements that would be made on returned samples in terrestrial laboratories.</p

    PIXL: Planetary Instrument for X-Ray Lithochemistry

    No full text
    Planetary Instrument for X-ray Lithochemistry (PIXL) is a micro-focus X-ray fluorescence spectrometer mounted on the robotic arm of NASA’s Perseverance rover. PIXL will acquire high spatial resolution observations of rock and soil chemistry, rapidly analyzing the elemental chemistry of a target surface. In 10 seconds, PIXL can use its powerful 120 μm-diameter X-ray beam to analyze a single, sand-sized grain with enough sensitivity to detect major and minor rock-forming elements, as well as many trace elements. Over a period of several hours, PIXL can autonomously raster-scan an area of the rock surface and acquire a hyperspectral map comprised of several thousand individual measured points. When correlated to a visual image acquired by PIXL’s camera, these maps reveal the distribution and abundance variations of chemical elements making up the rock, tied accurately to the physical texture and structure of the rock, at a scale comparable to a 10X magnifying geological hand lens. The many thousands of spectra in these postage stamp-sized elemental maps may be analyzed individually or summed together to create a bulk rock analysis, or subsets of spectra may be summed, quantified, analyzed, and compared using PIXLISE data analysis software. This hand lens-scale view of the petrology and geochemistry of materials at the Perseverance landing site will provide a valuable link between the larger, centimeter- to meter-scale observations by Mastcam-Z, RIMFAX and Supercam, and the much smaller (micron-scale) measurements that would be made on returned samples in terrestrial laboratories

    Correction to: PIXL: Planetary Instrument for X-Ray Lithochemistry (Space Science Reviews, (2020), 216, 8, (134), 10.1007/s11214-020-00767-7)

    No full text
    In section: 3 X-Ray Source 3.1 X-Ray Source Overview The following text should not be present: “The X-ray source combines components from multiple organizations. The high-voltage power supply (HVPS), which includes the LVCM, HVMM, and connecting cables, was designed and built by Battel Engineering and the University of Michigan Space Physics Research Laboratory (SPRL). The X-ray tube was designed and built by Moxtek Inc., and the X-ray optic was designed and built by XOS Inc. XOS aligned and integrated the X-ray tube and optic, while SPRL integrated this tube/optic assembly into the XRSA.” Please also find the corrected: Appendix A: Parameters This is a complete list of parameters that are in place when a scan is initiated that are returned in data products. All of these can be changed by uplink (Table presented.).</p

    The Dalton quantum chemistry program system

    No full text
    Dalton is a powerful general-purpose program system for the study of molecular electronic structure at the Hartree–Fock, Kohn–Sham, multiconfigurational self-consistent-field, Møller–Plesset, configuration-interaction, and coupled-cluster levels of theory. Apart from the total energy, a wide variety of molecular properties may be calculated using these electronic-structure models. Molecular gradients and Hessians are available for geometry optimizations, molecular dynamics, and vibrational studies, whereas magnetic resonance and optical activity can be studied in a gauge-origin-invariant manner. Frequency-dependent molecular properties can be calculated using linear, quadratic, and cubic response theory. A large number of singlet and triplet perturbation operators are available for the study of one-, two-, and three-photon processes. Environmental effects may be included using various dielectric-medium and quantum-mechanics/molecular-mechanics models. Large molecules may be studied using linear-scaling and massively parallel algorithms. Dalton is distributed at no cost from http://www.daltonprogram.org for a number of UNIX platforms
    corecore