5 research outputs found

    Development of the natural working fluid‐based refrigeration system for domestic scale freeze‐dryer

    Get PDF
    In this work, the analysis of the refrigeration system designed for the FrostX 10 freeze‐dryer is presented. The main goal of this study was to experimentally investigate the reference R452a freeze‐dryer and prepare recommendations for a machine based on the R290 refrigeration unit. In order to guarantee the temperature requirements and efficient operation of that unit, the analysis of suitable natural refrigerants was performed. Consequently, propane (R290) was selected. In addition, a number of modifications were introduced for the prototype system. System analysis showed that the replacement of the refrigerant in the existing system improves the system energy efficiency by approximately 18%. During the experimental campaign of the basic refrigeration unit, an unstable operation of the evaporator was found. The concept of a new cooling system for a prototype device was presented. The configuration and type of heat exchanger to maximise the performance of the ice trap of the freeze‐dryer were proposed.Development of the natural working fluid‐based refrigeration system for domestic scale freeze‐dryeracceptedVersio

    Thermal analysis of 8.5 MVA disk-type power transformer cooled by biodegradable ester oil working in ONAN mode by using advanced EMAG–CFD–CFD coupling

    Get PDF
    Power transformers are the first devices used to transfer the electrical energy produced in power plants to the grid to supply the industrial and individual receivers with electricity. The heat generation in windings and core, being an effect of the power losses, is usually dissipated in large units by using mineral oils, which are harmful to the environment. Nowadays, the industry and global society seek environmentally-friendly alternatives. One of the most promising substitute for their high biodegradability, safety in operation, and favourable thermo-physical properties are natural ester oils. For this reason, a numerical study of 8.5 MVA disk-type power transformer cooled using conventional mineral oil and a commercially used rapeseed ester oil is presented in this paper. Moreover, due to different thermal behaviour of the considered oils, the comparison was made for the unit working in different seasons of hot and moderate climate zones (Argentina and Poland). In the numerical approach, electromagnetic (EMAG) and computational fluid dynamics (CFD) models were used for a detailed study of the selected device. In particular, a novel and very efficient EMAG–CFD–CFD coupling procedure was developed to assess the cooling of the large power transformer. Such a coupled computational procedure allowed for the detailed investigation of the power loss, oil flow characteristics, and temperatures with a satisfying computational effort. The results showed that the average windings temperatures are higher by 2–9 K when the ester oil is used, dependent on the ambient conditions. The hotspot temperature in the low voltage windings increased by up to 9 K and up to 18 K in the high voltage windings using ester oil. According to the results, the oil duct construction requires modification in the high voltage region for transformers cooled using mineral oil in cold climate conditions.Fil: Stebel, Michal. Silesian University Of Technology; PoloniaFil: Kubiczek, Krzysztof. Silesian University Of Technology; PoloniaFil: Rios Rodriguez, Gustavo Adolfo. Consejo Nacional de Investigaciones CientĂ­ficas y TĂ©cnicas. Centro CientĂ­fico TecnolĂłgico Conicet - Santa Fe. Centro de Investigaciones en MĂ©todos Computacionales. Universidad Nacional del Litoral. Centro de Investigaciones en MĂ©todos Computacionales; ArgentinaFil: Palacz, Michal. Silesian University Of Technology; PoloniaFil: Garelli, Luciano. Consejo Nacional de Investigaciones CientĂ­ficas y TĂ©cnicas. Centro CientĂ­fico TecnolĂłgico Conicet - Santa Fe. Centro de Investigaciones en MĂ©todos Computacionales. Universidad Nacional del Litoral. Centro de Investigaciones en MĂ©todos Computacionales; ArgentinaFil: Melka, Bartlomiej. Silesian University Of Technology; PoloniaFil: Haida, Michal. Silesian University Of Technology; PoloniaFil: Bodys, Jakub. Silesian University Of Technology; PoloniaFil: Nowak, Andrzej J.. Silesian University Of Technology; PoloniaFil: Lasek, Pawel. Silesian University Of Technology; PoloniaFil: Stepien, Mariusz. Silesian University Of Technology; PoloniaFil: Pessolani, Francisco. Tadeo Czerweny S.a.; ArgentinaFil: Amadei, Mauro. Tadeo Czerweny S.a.; ArgentinaFil: Granata, Daniel. Tadeo Czerweny S.a.; ArgentinaFil: Storti, Mario Alberto. Consejo Nacional de Investigaciones CientĂ­ficas y TĂ©cnicas. Centro CientĂ­fico TecnolĂłgico Conicet - Santa Fe. Centro de Investigaciones en MĂ©todos Computacionales. Universidad Nacional del Litoral. Centro de Investigaciones en MĂ©todos Computacionales; ArgentinaFil: Smolka, Jacek. Silesian University Of Technology; Poloni

    Experimental study of a R290 variable geometry ejector

    No full text
    Ejectors are classified as fluid-dynamics controlled devices where the “component-scale” performances are imposed by the local-scale fluid dynamic phenomena. For this reason, ejector performances (measured by the pressure-entrainment ratio coordinate of the critical point) are determined by the connection of operation conditions, working fluid and geometrical parameters. Given such a connection, variable geometry ejector represents a promising solution to increase the flexibility of ejector-based systems. The present study aims to extend knowledge on variable geometry systems, evaluating the local and global performances of the R290 ejector equipped with a spindle. The prototype ejector was installed at the R290 vapour compression test rig adapted and modified for the required experimental campaign. The test campaign considered global parameter measurements, such as the pressure and the temperature at inlets and outlet ports together with the mass flow rates at both inlet nozzles, and the local pressure drop measurements inside the ejector. In addition, the experimental data were gathered for different spindle positions starting from fully open position the spindle position limited by the mass flow rate inside the test rig with the step of 1.0 mm

    Methodology of generation of CFD meshes and 4D shape reconstruction of coronary arteries from patient-specific dynamic CT

    No full text
    Abstract Due to the difficulties in retrieving both the time-dependent shapes of the vessels and the generation of numerical meshes for such cases, most of the simulations of blood flow in the cardiac arteries use static geometry. The article describes a methodology for generating a sequence of time-dependent 3D shapes based on images of different resolutions and qualities acquired from ECG-gated coronary artery CT angiography. The precision of the shape restoration method has been validated using an independent technique. The original proposed approach also generates for each of the retrieved vessel shapes a numerical mesh of the same topology (connectivity matrix), greatly simplifying the CFD blood flow simulations. This feature is of significant importance in practical CFD simulations, as it gives the possibility of using the mesh-morphing utility, minimizing the computation time and the need of interpolation between boundary meshes at subsequent time instants. The developed technique can be applied to generate numerical meshes in arteries and other organs whose shapes change over time. It is applicable to medical images produced by other than angio-CT modalities

    Development of the natural working fluid‐based refrigeration system for domestic scale freeze‐dryer

    Get PDF
    In this work, the analysis of the refrigeration system designed for the FrostX 10 freeze‐dryer is presented. The main goal of this study was to experimentally investigate the reference R452a freeze‐dryer and prepare recommendations for a machine based on the R290 refrigeration unit. In order to guarantee the temperature requirements and efficient operation of that unit, the analysis of suitable natural refrigerants was performed. Consequently, propane (R290) was selected. In addition, a number of modifications were introduced for the prototype system. System analysis showed that the replacement of the refrigerant in the existing system improves the system energy efficiency by approximately 18%. During the experimental campaign of the basic refrigeration unit, an unstable operation of the evaporator was found. The concept of a new cooling system for a prototype device was presented. The configuration and type of heat exchanger to maximise the performance of the ice trap of the freeze‐dryer were proposed
    corecore