3 research outputs found
Comparison of an analytical and computational fluid-dynamics models of a commercial Ranque-Hilsch vortex tube operating with Air and Methane
This paper presents a comparison between the behavior predicted by a computational fluid-dynamic model (CFD) and an analytical model for a commercial vortex tube using air and methane as working fluids, in addition to a three-dimensional mesh for this purpose. The numerical simulation of the turbulent, compressible and high vorticity flow was carried out using RANS equations, the Realizable k-e turbulence model and STAR-CCM+ as software for the equations solution. The variables measured in this work were temperature, pressure and velocity at the exit nozzles of the vortex generator and the tube discharges, resulting in errors of less than 16% between CFD and the analytical model. This numerical study represents a first approximation of the vorticityphenomenon and has been developed in order to establish a prototype simulation model that provides, under certain inlet conditions to the process, preliminary information on the vortex tube industrial implementation for obtaining liquefied natural gas
Libro Digital Proyectos Posgrados 2015-30
MaestríaDoctoradoDoctor en Ingeniería Eléctrica y ElectrónicaDoctor en Ingeniería CivilDoctor en Ingeniería de Sistemas y ComputaciónDoctor en Ingeniería IndustrialDoctor en Ingeniería MecánicaMagister en Gobierno de Tecnología InformáticaMagister en Ingeniería AdministrativaMagister en Ingeniería AmbientalMagister en Ingeniería CivilMagister en Ingeniería de Sistemas y ComputaciónMagister en Ingeniería EléctricaMagister en Ingeniería ElectrónicaMagister en Ingeniería IndustrialMagister en Ingeniería Mecánic
Worldwide Disparities in Recovery of Cardiac Testing 1 Year Into COVID-19
BACKGROUND The extent to which health care systems have adapted to the COVID-19 pandemic to provide necessary cardiac diagnostic services is unknown.OBJECTIVES The aim of this study was to determine the impact of the pandemic on cardiac testing practices, volumes and types of diagnostic services, and perceived psychological stress to health care providers worldwide.METHODS The International Atomic Energy Agency conducted a worldwide survey assessing alterations from baseline in cardiovascular diagnostic care at the pandemic's onset and 1 year later. Multivariable regression was used to determine factors associated with procedure volume recovery.RESULTS Surveys were submitted from 669 centers in 107 countries. Worldwide reduction in cardiac procedure volumes of 64% from March 2019 to April 2020 recovered by April 2021 in high- and upper middle-income countries (recovery rates of 108% and 99%) but remained depressed in lower middle- and low-income countries (46% and 30% recovery). Although stress testing was used 12% less frequently in 2021 than in 2019, coronary computed tomographic angiography was used 14% more, a trend also seen for other advanced cardiac imaging modalities (positron emission tomography and magnetic resonance; 22%-25% increases). Pandemic-related psychological stress was estimated to have affected nearly 40% of staff, impacting patient care at 78% of sites. In multivariable regression, only lower-income status and physicians' psychological stress were significant in predicting recovery of cardiac testing.CONCLUSIONS Cardiac diagnostic testing has yet to recover to prepandemic levels in lower-income countries. Worldwide, the decrease in standard stress testing is offset by greater use of advanced cardiac imaging modalities. Pandemic-related psychological stress among providers is widespread and associated with poor recovery of cardiac testing. (C) 2022 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation