86 research outputs found

    Nocturnal Lifestyle Behaviours and Risk of Poor Sleep during Pregnancy

    Get PDF
    The extent to which lifestyle practices at night influence sleep quality in pregnant women remains unknown. This study aimed to examine whether nocturnal behaviours were associated with poor sleep during pregnancy. We performed a cross-sectional analysis of a prospective cohort of pregnant women at 18–24 gestation weeks recruited from KK Women’s and Children’s Hospital, Singapore, between 2019 and 2021. Nocturnal behaviours were assessed with questionnaires, and sleep quality was measured using the Pittsburgh Sleep Quality Index (PSQI) with a global score ≥5 indicative of poor sleep quality. Modified Poisson regression and linear regression were used to examine the association between nocturnal behaviour and sleep quality. Of 299 women, 117 (39.1%) experienced poor sleep. In the covariate-adjusted analysis, poor sleep was observed in women with nocturnal eating (risk ratio 1.51; 95% confidence interval [CI] 1.12, 2.04) and nocturnal artificial light exposure (1.63; 1.24, 2.13). Similarly, nocturnal eating (β 0.68; 95% CI 0.03, 1.32) and light exposure (1.99; 1.04, 2.94) were associated with higher PSQI score. Nocturnal physical activity and screen viewing before bedtime were not associated with sleep quality. In conclusion, reducing nocturnal eating and light exposure at night could potentially improve sleep in pregnancy.publishedVersionPeer reviewe

    Potential of Core-Collapse Supernova Neutrino Detection at JUNO

    Get PDF
    JUNO is an underground neutrino observatory under construction in Jiangmen, China. It uses 20kton liquid scintillator as target, which enables it to detect supernova burst neutrinos of a large statistics for the next galactic core-collapse supernova (CCSN) and also pre-supernova neutrinos from the nearby CCSN progenitors. All flavors of supernova burst neutrinos can be detected by JUNO via several interaction channels, including inverse beta decay, elastic scattering on electron and proton, interactions on C12 nuclei, etc. This retains the possibility for JUNO to reconstruct the energy spectra of supernova burst neutrinos of all flavors. The real time monitoring systems based on FPGA and DAQ are under development in JUNO, which allow prompt alert and trigger-less data acquisition of CCSN events. The alert performances of both monitoring systems have been thoroughly studied using simulations. Moreover, once a CCSN is tagged, the system can give fast characterizations, such as directionality and light curve

    Detection of the Diffuse Supernova Neutrino Background with JUNO

    Get PDF
    As an underground multi-purpose neutrino detector with 20 kton liquid scintillator, Jiangmen Underground Neutrino Observatory (JUNO) is competitive with and complementary to the water-Cherenkov detectors on the search for the diffuse supernova neutrino background (DSNB). Typical supernova models predict 2-4 events per year within the optimal observation window in the JUNO detector. The dominant background is from the neutral-current (NC) interaction of atmospheric neutrinos with 12C nuclei, which surpasses the DSNB by more than one order of magnitude. We evaluated the systematic uncertainty of NC background from the spread of a variety of data-driven models and further developed a method to determine NC background within 15\% with {\it{in}} {\it{situ}} measurements after ten years of running. Besides, the NC-like backgrounds can be effectively suppressed by the intrinsic pulse-shape discrimination (PSD) capabilities of liquid scintillators. In this talk, I will present in detail the improvements on NC background uncertainty evaluation, PSD discriminator development, and finally, the potential of DSNB sensitivity in JUNO

    Real-time Monitoring for the Next Core-Collapse Supernova in JUNO

    Full text link
    Core-collapse supernova (CCSN) is one of the most energetic astrophysical events in the Universe. The early and prompt detection of neutrinos before (pre-SN) and during the SN burst is a unique opportunity to realize the multi-messenger observation of the CCSN events. In this work, we describe the monitoring concept and present the sensitivity of the system to the pre-SN and SN neutrinos at the Jiangmen Underground Neutrino Observatory (JUNO), which is a 20 kton liquid scintillator detector under construction in South China. The real-time monitoring system is designed with both the prompt monitors on the electronic board and online monitors at the data acquisition stage, in order to ensure both the alert speed and alert coverage of progenitor stars. By assuming a false alert rate of 1 per year, this monitoring system can be sensitive to the pre-SN neutrinos up to the distance of about 1.6 (0.9) kpc and SN neutrinos up to about 370 (360) kpc for a progenitor mass of 30MM_{\odot} for the case of normal (inverted) mass ordering. The pointing ability of the CCSN is evaluated by using the accumulated event anisotropy of the inverse beta decay interactions from pre-SN or SN neutrinos, which, along with the early alert, can play important roles for the followup multi-messenger observations of the next Galactic or nearby extragalactic CCSN.Comment: 24 pages, 9 figure

    Rivaroxaban Compared with Standard Anticoagulants for the Treatment of Acute Venous Thromboembolism in Children: a Randomised, Controlled, Phase 3 Trial

    Full text link
    Background: Treatment of venous thromboembolism in children is based on data obtained in adults with little direct documentation of its efficacy and safety in children. The aim of our study was to compare the efficacy and safety of rivaroxaban versus standard anticoagulants in children with venous thromboembolism. Methods: In a multicentre, parallel-group, open-label, randomised study, children (aged 0–17 years) attending 107 paediatric hospitals in 28 countries with documented acute venous thromboembolism who had started heparinisation were assigned (2:1) to bodyweight-adjusted rivaroxaban (tablets or suspension) in a 20-mg equivalent dose or standard anticoagulants (heparin or switched to vitamin K antagonist). Randomisation was stratified by age and venous thromboembolism site. The main treatment period was 3 months (1 month in children <2 years of age with catheter-related venous thromboembolism). The primary efficacy outcome, symptomatic recurrent venous thromboembolism (assessed by intention-to-treat), and the principal safety outcome, major or clinically relevant non-major bleeding (assessed in participants who received ≥1 dose), were centrally assessed by investigators who were unaware of treatment assignment. Repeat imaging was obtained at the end of the main treatment period and compared with baseline imaging tests. This trial is registered with ClinicalTrials.gov, number NCT02234843 and has been completed. Findings: From Nov 14, 2014, to Sept 28, 2018, 500 (96%) of the 520 children screened for eligibility were enrolled. After a median follow-up of 91 days (IQR 87–95) in children who had a study treatment period of 3 months (n=463) and 31 days (IQR 29–35) in children who had a study treatment period of 1 month (n=37), symptomatic recurrent venous thromboembolism occurred in four (1%) of 335 children receiving rivaroxaban and five (3%) of 165 receiving standard anticoagulants (hazard ratio [HR] 0·40, 95% CI 0·11–1·41). Repeat imaging showed an improved effect of rivaroxaban on thrombotic burden as compared with standard anticoagulants (p=0·012). Major or clinically relevant non-major bleeding in participants who received ≥1 dose occurred in ten (3%) of 329 children (all non-major) receiving rivaroxaban and in three (2%) of 162 children (two major and one non-major) receiving standard anticoagulants (HR 1·58, 95% CI 0·51–6·27). Absolute and relative efficacy and safety estimates of rivaroxaban versus standard anticoagulation estimates were similar to those in rivaroxaban studies in adults. There were no treatment-related deaths. Interpretation: In children with acute venous thromboembolism, treatment with rivaroxaban resulted in a similarly low recurrence risk and reduced thrombotic burden without increased bleeding, as compared with standard anticoagulants. Funding: Bayer AG and Janssen Research & Development. © 2020 Elsevier Ltd

    Car ownership in Singapore : from vehicle quota system to usage cost system.

    No full text
    This Project explores the possibilities of changing the current transport system to one that bases on usage cost instead of ownership cost

    Boat Quay : its past, present and future.

    No full text
    This research examines the effectiveness of Boat Quay's marketing strategy in light of the problems it currently faces and possible recommendations on the future marketing plans are made
    corecore