20 research outputs found

    Laser-wakefield accelerators as hard x-ray sources for 3D medical imaging of human bone

    Get PDF
    A bright μm-sized source of hard synchrotron x-rays (critical energy Ecrit > 30 keV) based on the betatron oscillations of laser wakefield accelerated electrons has been developed. The potential of this source for medical imaging was demonstrated by performing micro-computed tomography of a human femoral trabecular bone sample, allowing full 3D reconstruction to a resolution below 50 μm. The use of a 1 cm long wakefield accelerator means that the length of the beamline (excluding the laser) is dominated by the x-ray imaging distances rather than the electron acceleration distances. The source possesses high peak brightness, which allows each image to be recorded with a single exposure and reduces the time required for a full tomographic scan. These properties make this an interesting laboratory source for many tomographic imaging applications

    Direct fluorescence characterisation of a picosecond seeded optical parametric amplifier

    Get PDF
    The temporal intensity contrast of high-power lasers based on optical parametric amplification (OPA) can be limited by parametric fluorescence from the non-linear gain stages. Here we present a spectroscopic method for direct measurement of unwanted parametric fluorescence widely applicable from unseeded to fully seeded and saturated OPA operation. Our technique employs simultaneous spectroscopy of fluorescence photons slightly outside the seed bandwidth and strongly attenuated light at the seed central wavelength. To demonstrate its applicability we have characterised the performance of a two-stage picosecond OPA pre-amplifier with 2.8×105 gain, delivering pulses at 1054 nm. We show that fluorescence from a strongly seeded OPA is reduced by ~500× from the undepleted to full pump depletion regimes. We also determine the vacuum fluctuation driven noise term seeding this OPA fluorescence to be 0.7±0.4 photons ps−1 nm−1 bandwidth. The resulting shot-to-shot statistics highlights a 1.5% probability of a five-fold and 0.3% probability of a ten-fold increase of fluorescence above the average value. Finally, we show that OPA fluorescence can be limited to a few-ps pedestal with 3×10−9 temporal intensity contrast 1.3 ps ahead of an intense laser pulse, a level highly attractive for large scale chirped-pulse OPA laser systems

    Spectral enhancement in optical parametric amplifiers in the saturated regime

    No full text
    We present numerical and experimental studies on a front-end laser system for seeding a sub-picosecond multi-terawatt/petawatt light source based on two highly saturated optical parametric amplifiers. Numerical results showing energy gain, spectral gain, and stability as saturation is approached are presented. An experimental realisation of the system has been constructed, and its performance has been found to be in good agreement with the numerical simulations. The total gain is in excess of 105 over a few picosecond gain window, and the pulse energy is ∼100 μJ with 4 % root mean square stability. © 2013 Springer-Verlag Berlin Heidelberg
    corecore