762 research outputs found

    Which cuff should I use? Indirect blood pressure measurement for the diagnosis of hypertension in patients with obesity: a diagnostic accuracy review.

    Get PDF
    OBJECTIVE: To determine the diagnostic accuracy of different methods of blood pressure (BP) measurement compared with reference standards for the diagnosis of hypertension in patients with obesity with a large arm circumference. DESIGN: Systematic review with meta-analysis with hierarchical summary receiver operating characteristic models. Bland-Altman analyses where individual patient data were available. Methodological quality appraised using Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS2) criteria. DATA SOURCES: MEDLINE, EMBASE, Cochrane, DARE, Medion and Trip databases were searched. ELIGIBILITY CRITERIA: Cross-sectional, randomised and cohort studies of diagnostic test accuracy that compared any non-invasive BP tests (upper arm, forearm, wrist, finger) with an appropriate reference standard (invasive BP, correctly fitting upper arm cuff, ambulatory BP monitoring) in primary care were included. RESULTS: 4037 potentially relevant papers were identified. 20 studies involving 26 different comparisons met the inclusion criteria. Individual patient data were available from 4 studies. No studies satisfied all QUADAS2 criteria. Compared with the reference test of invasive BP, a correctly fitting upper arm BP cuff had a sensitivity of 0.87 (0.79 to 0.93) and a specificity of 0.85 (0.64 to 0.95); insufficient evidence was available for other comparisons to invasive BP. Compared with the reference test of a correctly fitting upper arm cuff, BP measurement at the wrist had a sensitivity of 0.92 (0.64 to 0.99) and a specificity of 0.92 (0.85 to 0.87). Measurement with an incorrectly fitting standard cuff had a sensitivity of 0.73 (0.67 to 0.78) and a specificity of 0.76 (0.69 to 0.82). Measurement at the forearm had a sensitivity of 0.84 (0.71 to 0.92) and a specificity 0.75 of (0.66 to 0.83). Bland-Altman analysis of individual patient data from 3 studies comparing wrist and upper arm BP showed a mean difference of 0.46 mm Hg for systolic BP measurement and 2.2 mm Hg for diastolic BP measurement. CONCLUSIONS: BP measurement with a correctly fitting upper arm cuff is sufficiently sensitive and specific to diagnose hypertension in patients with obesity with a large upper arm circumference. If a correctly fitting upper arm cuff cannot be applied, an incorrectly fitting standard size cuff should not be used and BP measurement at the wrist should be considered

    Adaption, implementation and evaluation of collaborative service improvements in the testing and result communication process in primary care from patient and staff perspectives : a qualitative study

    Get PDF
    BACKGROUND: Increasing numbers of blood tests are being ordered in primary care settings and the swift and accurate communication of test results is central to providing high quality care. The process of testing and result communication is complex and reliant on the coordinated actions of care providers, external groups in laboratory and hospital settings, and patients. This fragmentation leaves it vulnerable to error and the need to improve an apparently fallible system is apparent. However, primary care is complex and does not necessarily adopt change in a linear and prescribed manner influenced by a range of factors relating to practice staff, patients and organisational factors. To account for these competing perspectives, we worked in conjunction with both staff and patients to develop and implement strategies intended to improve patient satisfaction and increase efficiency of existing processes. METHODS: The study applied the principles of 'experience-based co-design' to identify key areas of weakness and source proposals for change from staff and patients. The study was undertaken within two primary practices situated in South Birmingham (UK) of contrasting size and socio-economic environment. Senior practice staff were involved in the refinement of the interventions for introduction. We conducted focus groups singly constituted of staff and patients at each practice to determine suitability, applicability and desirability alongside the practical implications of their introduction. RESULTS: At each practice four of the six proposals for change were implemented these were increased access to phlebotomy, improved receptionist training, proactive communication of results, and increased patient awareness of the tests ordered and the means of their communication. All were received favourably by both patients and staff. The remaining issues around the management of telephone calls and the introduction of electronic alerts for missing results were not addressed due to constraints of time and available resources. CONCLUSIONS: Approaches to tackling the same area of weakness differed at practices and was determined by individual staff attitudes and by organisational and patient characteristics. The long-term impact of the changes requires further quantitative evaluation

    Prevalence and costs of treating uncomplicated stage 1 hypertension in primary care: a cross-sectional analysis.

    Get PDF
    BACKGROUND: Treatment for uncomplicated stage 1 hypertension is recommended in most international guidelines but there is little evidence to indicate that therapy is beneficial. AIM: To estimate the prevalence of this condition in an untreated population and the potential costs of initiating therapy in such patients. DESIGN AND SETTING: Cross-sectional study of anonymised patient records in 19 general practices in the West Midlands, UK. METHOD: Data relating to patient demographics, existing cardiovascular disease (CVD), and risk factors (blood pressure and cholesterol) were extracted from patient records. Patients with a blood pressure of 140/90-159/99 mmHg, no CVD, and <20% 10-year cardiovascular risk were classified as having uncomplicated stage 1 hypertension. Missing data were imputed. The prevalence of untreated, uncomplicated stage 1 hypertension was estimated using descriptive statistics and extrapolated using national data. The cost of achieving blood pressure control in this population was examined in a cost-impact analysis using published costs from previous studies. RESULTS: Of the 34 975 patients (aged 40-74 years) in this study, untreated, uncomplicated stage 1 hypertension was present in 2867 individuals (8.2%, 95% confidence interval [CI] = 7.9 to 8.5). This is equivalent to 1 892 519 patients in England and Wales, for whom the additional cost of controlling blood pressure, according to guidelines, was estimated at £106-229 million per annum, depending on the health professional delivering care. CONCLUSION: Untreated, uncomplicated stage 1 hypertension is relatively common, affecting 1 in 12 patients aged 40-74 years in primary care. Current international guidelines and pay-for-performance targets, if followed, will incur significant costs for a patient benefit that is debatable.This work forms part of a larger programme on stroke prevention in primary care supported by the National Institute for Health Research (NIHR) (RP-PG-0606-1153). James P Sheppard holds a Medical Research Council Strategic Skills PostDoctoral Fellowship. Richard J McManus holds an NIHR Professorship. The views and opinions expressed are those of the authors and do not necessarily reflect those of the NHS, NIHR, or the Department of Health

    Effect of the quality and outcomes framework on diabetes care in the United Kingdom: retrospective cohort study

    Get PDF
    Objectives To examine the management of diabetes between 2001 and 2007 in the United Kingdom and to assess whether changes in the quality of care reflect existing temporal trends or are a direct result of the implementation of the quality and outcomes framework

    Medical telemonitoring for the management of hypertension in older patients in Japan

    Get PDF
    Hypertension is the most frequent modifiable risk factor associated with cardiovascular disease (CVD) morbidity and mortality. Even in older people, strict blood pressure (BP) control has been recommended to reduce CVD event risks. However, caution should be exercised since older hypertensive patients have increased physical vulnerability due to frailty and multimorbidity, and older patients eligible for clinical trials may not represent the general population. Medical telemonitoring systems, which enable us to monitor a patient's medical condition remotely through digital communication, have become much more prevalent since the coronavirus pandemic. Among various physiological parameters, BP monitoring is well-suited to the use of such systems, which enable healthcare providers to deliver accurate and safe BP management, even in the presence of frailty and/or living in geographically remote areas. Furthermore, medical telemonitoring systems could help reduce nonadherence to antihypertensive medications and clinical inertia, and also enable multi-professional team-based management of hypertension. However, the implementation of medical telemonitoring systems in clinical practice is not easy, and substantial barriers, including the development of user-friendly devices, integration with existing clinical systems, data security, and cost of implementation and maintenance, need to be overcome. In this review, we focus on the potential of medical telemonitoring for the management of hypertension in older people in Japan

    Using self-monitoring to detect and manage raised blood pressure and pre-eclampsia during pregnancy: the BUMP research programme and its impact

    Get PDF
    Raised blood pressure affects around ten percent of pregnancies worldwide, causing maternal and perinatal morbidity and mortality. Self-monitoring of blood pressure during higher-risk or hypertensive pregnancy has been shown to be feasible, acceptable, safe, and no more expensive than usual care alone. Additionally, self-testing for proteinuria has been shown to be just as accurate as healthcare professional testing, creating the potential for monitoring of multiple indicators through pregnancy. The work suggests however, that an organisational shift is needed to properly use and see benefits from self-monitored readings. This paper describes the findings from a large programme of work examining the use of self-monitoring in pregnancy, summarising the findings in the context of the wider literature and current clinical context

    Impact of Changes to National Hypertension Guidelines on Hypertension Management and Outcomes in the United Kingdom.

    Get PDF
    In recent years, national and international guidelines have recommended the use of out-of-office blood pressure monitoring for diagnosing hypertension. Despite evidence of cost-effectiveness, critics expressed concerns this would increase cardiovascular morbidity. We assessed the impact of these changes on the incidence of hypertension, out-of-office monitoring and cardiovascular morbidity using routine clinical data from English general practices, linked to inpatient hospital, mortality, and socio-economic status data. We studied 3 937 191 adults with median follow-up of 4.2 years (49% men, mean age=39.7 years) between April 1, 2006 and March 31, 2017. Interrupted time series analysis was used to examine the impact of changes to English hypertension guidelines in 2011 on incidence of hypertension (primary outcome). Secondary outcomes included rate of out-of-office monitoring and cardiovascular events. Across the study period, incidence of hypertension fell from 2.1 to 1.4 per 100 person-years. The change in guidance in 2011 was not associated with an immediate change in incidence (change in rate=0.01 [95% CI, -0.18-0.20]) but did result in a leveling out of the downward trend (change in yearly trend =0.09 [95% CI, 0.04-0.15]). Ambulatory monitoring increased significantly in 2011/2012 (change in rate =0.52 [95% CI, 0.43-0.60]). The rate of cardiovascular events remained unchanged (change in rate =-0.02 [95% CI, -0.05-0.02]). In summary, changes to hypertension guidelines in 2011 were associated with a stabilisation in incidence and no increase in cardiovascular events. Guidelines should continue to recommend out-of-office monitoring for diagnosis of hypertension

    Perspectives from the water: Utilizing fisher’s observations to inform SNE/ MA windowpane science and managemen

    Get PDF
    Within fisheries, stakeholders often have varying viewpoints regarding natural marine resources, and use different sets information to evaluate their condition. Evaluating a resource with different sets of information can lead to different conclusions. Windowpane flounder (Scophthalmus aquosus) are a managed finfish species in the northwest Atlantic whose regulations have the potential to limit harvest opportunities for target species. We analyzed commercial trip and catch information from video data to understand local densities of windowpane flounder in conjunction with fisheries independent surveys. Video monitoring data from three Rhode Island commercial fisher’s vessels and fisheries independent trawl survey data were analyzed to understand the geographic distribution of the stock as well as overlap with temporary closed areas. Biomass data from the fisheries-dependent and fisheries-independent surveys were combined with a spatial-temporal model that accounted for differences in catchability among vessels and spatial autocorrelation. A separate analysis of esti-mated discard rates with observer data was also conducted to determine how the distribution of windowpane discards in Southern New England compared to the distribution of model predicted windowpane abundance. In agreement with the fishermen’s observations, the temporary closed areas were not located where the highest densities of windowpane flounder occurred. The temporary closed areas, however, were located where the highest rates of discards occurred and thus where fishing had the greatest impact on the stock. The integration of verified fishery-dependent data with the scientific surveys has the potential to create a single set of information that is trusted by all user groups
    • …
    corecore