249 research outputs found

    Weighted Least-Squares Finite Element Method for Cardiac Blood Flow Simulation with Echocardiographic Data

    Get PDF
    As both fluid flow measurement techniques and computer simulation methods continue to improve, there is a growing need for numerical simulation approaches that can assimilate experimental data into the simulation in a flexible and mathematically consistent manner. The problem of interest here is the simulation of blood flow in the left ventricle with the assimilation of experimental data provided by ultrasound imaging of microbubbles in the blood. The weighted least-squares finite element method is used because it allows data to be assimilated in a very flexible manner so that accurate measurements are more closely matched with the numerical solution than less accurate data. This approach is applied to two different test problems: a flexible flap that is displaced by a jet of fluid and blood flow in the porcine left ventricle. By adjusting how closely the simulation matches the experimental data, one can observe potential inaccuracies in the model because the simulation without experimental data differs significantly from the simulation with the data. Additionally, the assimilation of experimental data can help the simulation capture certain small effects that are present in the experiment, but not modeled directly in the simulation

    Design of 280 GHz feedhorn-coupled TES arrays for the balloon-borne polarimeter SPIDER

    Full text link
    We describe 280 GHz bolometric detector arrays that instrument the balloon-borne polarimeter SPIDER. A primary science goal of SPIDER is to measure the large-scale B-mode polarization of the cosmic microwave background in search of the cosmic-inflation, gravitational-wave signature. 280 GHz channels aid this science goal by constraining the level of B-mode contamination from galactic dust emission. We present the focal plane unit design, which consists of a 16×\times16 array of conical, corrugated feedhorns coupled to a monolithic detector array fabricated on a 150 mm diameter silicon wafer. Detector arrays are capable of polarimetric sensing via waveguide probe-coupling to a multiplexed array of transition-edge-sensor (TES) bolometers. The SPIDER receiver has three focal plane units at 280 GHz, which in total contains 765 spatial pixels and 1,530 polarization sensitive bolometers. By fabrication and measurement of single feedhorns, we demonstrate 14.7^{\circ} FHWM Gaussian-shaped beams with <<1% ellipticity in a 30% fractional bandwidth centered at 280 GHz. We present electromagnetic simulations of the detection circuit, which show 94% band-averaged, single-polarization coupling efficiency, 3% reflection and 3% radiative loss. Lastly, we demonstrate a low thermal conductance bolometer, which is well-described by a simple TES model and exhibits an electrical noise equivalent power (NEP) = 2.6 ×\times 1017^{-17} W/Hz\sqrt{\mathrm{Hz}}, consistent with the phonon noise prediction.Comment: Proceedings of SPIE Astronomical Telescopes + Instrumentation 201

    CMB-S4 Science Book, First Edition

    Full text link
    This book lays out the scientific goals to be addressed by the next-generation ground-based cosmic microwave background experiment, CMB-S4, envisioned to consist of dedicated telescopes at the South Pole, the high Chilean Atacama plateau and possibly a northern hemisphere site, all equipped with new superconducting cameras. CMB-S4 will dramatically advance cosmological studies by crossing critical thresholds in the search for the B-mode polarization signature of primordial gravitational waves, in the determination of the number and masses of the neutrinos, in the search for evidence of new light relics, in constraining the nature of dark energy, and in testing general relativity on large scales

    Treatment with indinavir, zidovudine, and lamivudine in adults with human immunodeficiency virus infection and prior antiretroviral therapy

    Get PDF
    Background: The new protease inhibitors are potent inhibitors of the human immunodeficiency virus (HIV), and in combination with other antiretroviral drugs they may be able to cause profound and sustained suppression of HIV replication. Methods: In this double-blind study, 97 HIV-infected patients who had received zidovudine treatment for at least 6 months and had 50 to 400 CD4 cells per cubic millimeter and at least 20,000 copies of HIV RNA per milliliter were randomly assigned to one of three treatments for up to 52 weeks: 800 mg of indinavir every eight hours; 200 mg of zidovudine every eight hours combined with 150 mg of lamivudine twice daily; or all three drugs. The patients were followed to monitor the occurrence of adverse events and changes in viral load and CD4 cell counts. Results: The decrease in HIV RNA over the first 24 weeks was greater in the three-drug group than in the other groups (P�0.001 for each comparison). RNA levels decreased to less than 500 copies per milliliter at week 24 in 28 of 31 patients in the threedrug group (90 percent), 12 of 28 patients in the indinavir group (43 percent), and none of 30 patients in the zidovudine–lamivudine group. The increase in CD4 cell counts over the first 24 weeks was greater in the two groups receiving indinavir than in the zidovudine– lamivudine group (P<0.01 for each comparison). The changes in the viral load and the CD4 cell count persisted for up to 52 weeks. All the regimens were generally well tolerated. Conclusions: In most HIV-infected patients with prior antiretroviral therapy, the combination of indinavir, zidovudine, and lamivudine reduces levels of HIV RNA to less than 500 copies per milliliter for as long as one year. (N Engl J Med 1997;337:734-9.

    The Cosmology Large Angular Scale Surveyor Receiver Design

    Full text link
    The Cosmology Large Angular Scale Surveyor consists of four instruments performing a CMB polarization survey. Currently, the 40 GHz and first 90 GHz instruments are deployed and observing, with the second 90 GHz and a multichroic 150/220 GHz instrument to follow. The receiver is a central component of each instrument's design and functionality. This paper describes the CLASS receiver design, using the first 90 GHz receiver as a primary reference. Cryogenic cooling and filters maintain a cold, low-noise environment for the detectors. We have achieved receiver detector temperatures below 50 mK in the 40 GHz instrument for 85% of the initial 1.5 years of operation, and observed in-band efficiency that is consistent with pre-deployment estimates. At 90 GHz, less than 26% of in-band power is lost to the filters and lenses in the receiver, allowing for high optical efficiency. We discuss the mounting scheme for the filters and lenses, the alignment of the cold optics and detectors, stray light control, and magnetic shielding.Comment: Fixed formatting of abstract; 20 Pages, 11 Figures, SPIE Conference Proceeding
    corecore