5,701 research outputs found

    One-year follow-up of family versus child CBT for anxiety disorders: Exploring the roles of child age and parental intrusiveness.

    Get PDF
    ObjectiveTo compare the relative long-term benefit of family-focused cognitive behavioral therapy (FCBT) and child-focused cognitive behavioral therapy (CCBT) for child anxiety disorders at a 1-year follow-up.MethodThirty-five children (6-13 years old) randomly assigned to 12-16 sessions of family-focused CBT (FCBT) or child-focused CBT (CCBT) participated in a 1-year follow-up assessment. Independent evaluators, parents, and children rated anxiety and parental intrusiveness. All were blind to treatment condition and study hypotheses.ResultsChildren assigned to FCBT had lower anxiety scores than children assigned to CCBT on follow-up diagnostician- and parent-report scores, but not child-report scores. Exploratory analyses suggested the advantage of FCBT over CCBT may have been evident more for early adolescents than for younger children and that reductions in parental intrusiveness may have mediated the treatment effect.ConclusionFCBT may yield a stronger treatment effect than CCBT that lasts for at least 1 year, although the lack of consistency across informants necessitates a circumspect view of the findings. The potential moderating and mediating effects considered in this study offer interesting avenues for further study

    A simple method for the small scale synthesis and solid-phase extraction purification of steroid sulfates

    No full text
    Steroid sulfates are a major class of steroid metabolite that are of growing importance in fields such as anti-doping analysis, the detection of residues in agricultural produce or medicine. Despite this, many steroid sulfate reference materials may have limited or no availability hampering the development of analytical methods. We report simple protocols for the rapid synthesis and purification of steroid sulfates that are suitable for adoption by analytical laboratories. Central to this approach is the use of solid-phase extraction (SPE) for purification, a technique routinely used for sample preparation in analytical laboratories around the world. The sulfate conjugates of sixteen steroid compounds encompassing a wide range of steroid substitution patterns and configurations are prepared, including the previously unreported sulfate conjugates of the designer steroids furazadrol (17β-hydroxyandrostan[2,3-d]isoxazole), isofurazadrol (17β-hydroxyandrostan[3,2-c]isoxazole) and trenazone (17β-hydroxyestra-4,9-dien-3-one). Structural characterization data, together with NMR and mass spectra are reported for all steroid sulfates, often for the first time. The scope of this approach for small scale synthesis is highlighted by the sulfation of 1μg of testosterone (17β-hydroxyandrost-4-en-3-one) as monitored by liquid chromatography-mass spectrometry (LCMS).We thank the Australian Research Council (LP120200444) for financial support

    A review of designer anabolic steroids in equine sports

    Get PDF
    In recent years, the potential for anabolic steroid abuse in equine sports has increased due to the growing availability of designer steroids. These compounds are readily accessible online in 'dietary' or 'nutritional' supplements and contain steroidal compounds which have never been tested or approved as veterinary agents. They typically have unusual structures or substitution and as a result may pass undetected through current anti-doping screening protocols, making them a significant concern for the integrity of the industry. Despite considerable focus in human sports, until recently there has been limited investigation into these compounds in equine systems. To effectively respond to the threat of designer steroids, a detailed understanding of their metabolism is needed to identify markers and metabolites arising from their misuse. A summary of the literature detailing the metabolism of these compounds in equine systems is presented with an aim to identify metabolites suitable for incorporation into screening protocols by anti-doping laboratories. The future of equine anti-doping research is likely to be guided by the incorporation of alternate testing matrices into routine screening, the improvement of in vitro technologies that can mimic in vivo equine metabolism, and the improvement of instrumentation or analytical methods that allow for the development of untargeted screening, and metabolomics approaches for use in anti-doping screening protocols. Copyright © 2016 John Wiley & Sons, Ltd.ARC Linkage Project LP120200444 – Strategies for the detection of designer steroids in racehorse

    Results from the CASTLES Survey of Gravitational Lenses

    Full text link
    We show that most gravitational lenses lie on the passively evolving fundamental plane for early-type galaxies. For burst star formation models (1 Gyr of star formation, then quiescence) in low Omega_0 cosmologies, the stellar populations of the lens galaxies must have formed at z_f > 2. Typical lens galaxies contain modest amounts of patchy extinction, with a median differential extinction for the optical (radio) selected lenses of E(B-V) = 0.04 (0.07) mag. The dust can be used to determine both extinction laws and lens redshifts. For example, the z_l=0.96 elliptical lens in MG0414+0534 has an R_V=1.7 +/- 0.1 mean extinction law. Arc and ring images of the quasar and AGN source host galaxies are commonly seen in NICMOS H band observations. The hosts are typically blue, L < L_* galaxies.Comment: 12 pages, 10 figures, from Proceedings of the 9th Annual Astrophysics Conference in Maryland, After the Dark Ages: When Galaxies Were Youn

    Development of ultrasonic methods for hemodynamic measurements

    Get PDF
    A transcutanous method to measure instantaneous mean blood flow in peripheral arteries of the human body was defined. Transcutanous and implanted cuff ultrasound velocity measurements were evaluated, and the accuracies of velocity, flow, and diameter measurements were assessed for steady flow. Performance criteria were established for the pulsed Doppler velocity meter (PUDVM), and performance tests were conducted. Several improvements are suggested
    corecore