84 research outputs found

    Monolayer graphene bolometer as a sensitive far-IR detector

    Full text link
    In this paper we give a detailed analysis of the expected sensitivity and operating conditions in the power detection mode of a hot-electron bolometer (HEB) made from a few {\mu}m2^2 of monolayer graphene (MLG) flake which can be embedded into either a planar antenna or waveguide circuit via NbN (or NbTiN) superconducting contacts with critical temperature ~ 14 K. Recent data on the strength of the electron-phonon coupling are used in the present analysis and the contribution of the readout noise to the Noise Equivalent Power (NEP) is explicitly computed. The readout scheme utilizes Johnson Noise Thermometry (JNT) allowing for Frequency-Domain Multiplexing (FDM) using narrowband filter coupling of the HEBs. In general, the filter bandwidth and the summing amplifier noise have a significant effect on the overall system sensitivity. The analysis shows that the readout contribution can be reduced to that of the bolometer phonon noise if the detector device is operated at 0.05 K and the JNT signal is read at about 10 GHz where the Johnson noise emitted in equilibrium is substantially reduced. Beside the high sensitivity (NEP < 10−20^{-20} W/Hz1/2^{1/2}, this bolometer does not have any hard saturation limit and thus can be used for far-IR sky imaging with arbitrary contrast. By changing the operating temperature of the bolometer the sensitivity can be fine tuned to accommodate the background photon flux in a particular application. By using a broadband low-noise kinetic inductance parametric amplifier, ~100s of graphene HEBs can be read simultaneously without saturation of the system output.Comment: 9 pages. 6 figure, SPIE Astronomical Telescopes + Instrumentation, Montr\'eal, Quebec, Canada, 22-27 June, 201

    Terahertz detection mechanism and contact capacitance of individual metallic single-walled carbon nanotubes

    Full text link
    We characterize the terahertz detection mechanism in antenna-coupled metallic single-walled carbon nanotubes. At low temperature, 4.2 K, a peak in the low-frequency differential resistance is observed at zero bias current due to non-Ohmic contacts. This electrical contact nonlinearity gives rise to the measured terahertz response. By modeling each nanotube contact as a nonlinear resistor in parallel with a capacitor, we determine an upper bound for the value of the contact capacitance that is smaller than previous experimental estimates. The small magnitude of this contact capacitance has favorable implications for the use of carbon nanotubes in high-frequency device applications.Comment: 13 pages, 3 figures, 1 tabl

    Fluids and barriers of the CNS: a historical viewpoint

    Get PDF
    Tracing the exact origins of modern science can be a difficult but rewarding pursuit. It is possible for the astute reader to follow the background of any subject through the many important surviving texts from the classical and ancient world. While empirical investigations have been described by many since the time of Aristotle and scientific methods have been employed since the Middle Ages, the beginnings of modern science are generally accepted to have originated during the 'scientific revolution' of the 16th and 17th centuries in Europe. The scientific method is so fundamental to modern science that some philosophers consider earlier investigations as 'pre-science'. Notwithstanding this, the insight that can be gained from the study of the beginnings of a subject can prove important in the understanding of work more recently completed. As this journal undergoes an expansion in focus and nomenclature from cerebrospinal fluid (CSF) into all barriers of the central nervous system (CNS), this review traces the history of both the blood-CSF and blood-brain barriers from as early as it was possible to find references, to the time when modern concepts were established at the beginning of the 20th century
    • 

    corecore