1,113 research outputs found

    Metastable helium molecules as tracers in superfluid liquid 4^{4}He

    Get PDF
    Metastable helium molecules generated in a discharge near a sharp tungsten tip operated in either pulsed mode or continuous field-emission mode in superfluid liquid 4^{4}He are imaged using a laser-induced-fluorescence technique. By pulsing the tip, a small cloud of He2∗_{2}^{*} molecules is produced. At 2.0 K, the molecules in the liquid follow the motion of the normal fluid. We can determine the normal-fluid velocity in a heat-induced counterflow by tracing the position of a single molecule cloud. As we run the tip in continuous field-emission mode, a normal-fluid jet from the tip is generated and molecules are entrained in the jet. A focused 910 nm pump laser pulse is used to drive a small group of molecules to the vibrational a(1)a(1) state. Subsequent imaging of the tagged a(1)a(1) molecules with an expanded 925 nm probe laser pulse allows us to measure the velocity of the normal fluid. The techniques we developed demonstrate for the first time the ability to trace the normal-fluid component in superfluid helium using angstrom-sized particles.Comment: 4 pages, 7 figures. Submitted to Phys. Rev. Let

    A Path to the Direct Detection of sub-GeV Dark Matter Using Calorimetric Readout of a Superfluid 4^4He Target

    Get PDF
    A promising technology concept for sub-GeV dark matter detection is described, in which low-temperature microcalorimeters serve as the sensors and superfluid 4^4He serves as the target material. A superfluid helium target has several advantageous properties, including a light nuclear mass for better kinematic matching with light dark matter particles, copious production of scintillation light, extremely good intrinsic radiopurity, a high impedance to external vibration noise, and a unique mechanism for observing phonon-like modes via liberation of 4^4He atoms into a vacuum (`quantum evaporation'). In this concept, both scintillation photons and triplet excimers are detected using calorimeters, including calorimeters immersed in the superfluid. Kinetic excitations of the superfluid medium (rotons and phonons) are detected using quantum evaporation and subsequent atomic adsorption onto a microcalorimeter suspended in vacuum above the target helium. The energy of adsorption amplifies the phonon/roton signal before calorimetric sensing, producing a gain mechanism that can reduce the techonology's recoil energy threshold below the calorimeter energy threshold. We describe signal production and signal sensing probabilities, and estimate electron recoil discrimination. We then simulate radioactive backgrounds from gamma rays and neutrons. Dark matter - nucleon elastic scattering cross-section sensitivities are projected, demonstrating that even very small (sub-kg) target masses can probe wide regions of as-yet untested dark matter parameter space

    A 83Krm Source for Use in Low-background Liquid Xenon Time Projection Chambers

    Full text link
    We report the testing of a charcoal-based Kr-83m source for use in calibrating a low background two-phase liquid xenon detector. Kr-83m atoms produced through the decay of Rb-83 are introduced into a xenon detector by flowing xenon gas past the Rb-83 source. 9.4 keV and 32.1 keV transitions from decaying 83Krm nuclei are detected through liquid xenon scintillation and ionization. The characteristics of the Kr-83m source are analyzed and shown to be appropriate for a low background liquid xenon detector. Introduction of Kr-83m allows for quick, periodic calibration of low background noble liquid detectors at low energy.Comment: Updated to version submitted to JINS

    Calibration of liquid argon and neon detectors with 83Krm^{83}Kr^m

    Full text link
    We report results from tests of 83^{83}Krm^{\mathrm{m}}, as a calibration source in liquid argon and liquid neon. 83^{83}Krm^{\mathrm{m}} atoms are produced in the decay of 83^{83}Rb, and a clear 83^{83}Krm^{\mathrm{m}} scintillation peak at 41.5 keV appears in both liquids when filling our detector through a piece of zeolite coated with 83^{83}Rb. Based on this scintillation peak, we observe 6.0 photoelectrons/keV in liquid argon with a resolution of 6% (σ\sigma/E) and 3.0 photoelectrons/keV in liquid neon with a resolution of 19% (σ\sigma/E). The observed peak intensity subsequently decays with the 83^{83}Krm^{\mathrm{m}} half-life after stopping the fill, and we find evidence that the spatial location of 83^{83}Krm^{\mathrm{m}} atoms in the chamber can be resolved. 83^{83}Krm^{\mathrm{m}} will be a useful calibration source for liquid argon and neon dark matter and solar neutrino detectors.Comment: 7 pages, 12 figure

    Scintillation and charge extraction from the tracks of energetic electrons in superfluid helium-4

    Full text link
    An energetic electron passing through liquid helium causes ionization along its track. The ionized electrons quickly recombine with the resulting positive ions, which leads to the production of prompt scintillation light. By applying appropriate electric fields, some of the ionized electrons can be separated from their parent ions. The fraction of the ionized electrons extracted in a given applied field depends on the separation distance between the electrons and the ions. We report the determination of the mean electron-ion separation distance for charge pairs produced along the tracks of beta particles in superfluid helium at 1.5 K by studying the quenching of the scintillation light under applied electric fields. Knowledge of this mean separation parameter will aid in the design of particle detectors that use superfluid helium as a target material.Comment: 10 pages, 8 figure

    Calibration of a Liquid Xenon Detector with Kr-83m

    Full text link
    We report the preparation of a Kr-83m source and its subsequent use in calibrating a liquid xenon detector. Kr-83m atoms were produced through the decay of Rb-83 atoms trapped in zeolite molecular sieve and were then introduced into liquid xenon. Decaying Kr-83m nuclei were detected through liquid xenon scintillation. Conversion electrons with energies of 9.4 keV and 32.1 keV from the decay of Kr-83m were both observed. This calibration source will allow the characterization of the scintillation and ionization response of noble liquid detectors at low energies, highly valuable for the search for WIMP dark matter. Kr-83m may also be useful for measuring fluid flow dynamics, both to understand purification in noble liquid-based particle detectors, as well as for studies of classical and quantum turbulence in superfluid helium.Comment: Minor edits to match published versio

    Decidability of quantified propositional intuitionistic logic and S4 on trees

    Full text link
    Quantified propositional intuitionistic logic is obtained from propositional intuitionistic logic by adding quantifiers \forall p, \exists p over propositions. In the context of Kripke semantics, a proposition is a subset of the worlds in a model structure which is upward closed. Kremer (1997) has shown that the quantified propositional intuitionistic logic H\pi+ based on the class of all partial orders is recursively isomorphic to full second-order logic. He raised the question of whether the logic resulting from restriction to trees is axiomatizable. It is shown that it is, in fact, decidable. The methods used can also be used to establish the decidability of modal S4 with propositional quantification on similar types of Kripke structures.Comment: v2, 9 pages, corrections and additions; v1 8 page

    Observation of Crossover from Ballistic to Diffusion Regime for Excimer Molecules in Superfluid 4^4He

    Get PDF
    We have measured the temperature dependence of the time of flight of helium excimer molecules He2* in superfluid 4He and find that the molecules behave ballistically below 100mK and exhibit Brownian motion above 200 mK. In the intermediate temperature range the transport cannot be described by either of the models.Comment: 8 pages, 6 figures, submitted to the Proceedings of the International Conference on Quantum Fluids and Solids 201
    • …
    corecore