685 research outputs found

    Early removal versus expectant management of central venous catheters in neonates with bloodstream infection

    Get PDF
    BACKGROUND: Uncertainty exists regarding the management of newborn infants with a bloodstream infection and a central venous catheter in place. The central venous catheter may act as a nidus for infecting organisms and observational studies have suggested that early removal of the catheter is associated with a lower incidence of persistent or complicated infection. However, since central venous catheters provide secure vascular access to deliver nutrition and medications, the possible harms of early removal versus expectant management also need to be considered. OBJECTIVES: To determine the effect of early removal versus expectant management of central venous catheters on morbidity and mortality in newborn infants with bloodstream infections. SEARCH METHODS: We used the standard search strategy of the Cochrane Neonatal Review Group. This included searches of the Cochrane Central Register of Controlled Trials (CENTRAL 2015, Issue 11), MEDLINE (1966 to October 2015), EMBASE (1980 to October 2015), CINAHL (1982 to October 2015), conference proceedings and previous reviews. SELECTION CRITERIA: Randomised and quasi-randomised controlled trials that compared early removal versus expectant management of central venous catheters in neonates with bloodstream infections. DATA COLLECTION AND ANALYSIS: We used the standard methods of the Cochrane Neonatal Review Group. MAIN RESULTS: We did not identify any eligible randomised controlled trials. AUTHORS' CONCLUSIONS: There are no trial data to guide practice regarding early removal versus expectant management of central venous catheters in newborn infants with bloodstream infections. A simple and pragmatic randomised controlled trial is needed to resolve the uncertainty about optimal management in this common and important clinical scenario

    Tests on puddle weld connections

    Get PDF
    PREFACE This non-interpretive report contains the results of 90 tests on circular and oblong puddle weld connections. The connections involved test specimens constructed of flat steel plates and thin connecting sheets of varying thicknesses (10 to 28 gage) with the welds to be studied forning the bond between them. Testing consisted of tensile loading to ultimate failure. This work was carried out under contract with the Engineering Division of the American Iron and Steel Institute

    Determination of Uncertainties for Analytically Derived Material Properties to Be Used in Monte Carlo Based Orion Heatshield Sizing

    Get PDF
    Ablative materials are often used for spacecraft heatshields to protect underlying structures from the extreme environments associated with atmospheric reentry. NASA's Orion EM-1 capsule has been designed to use a molded Avcoat material system. In order to determine the required heatshield thickness, a Monte Carlo approach to the sizing process was proposed. To perform the Monte Carlo simulation, statistical uncertainties on all material property input parameters were required. Obtaining these values for measured properties is straightforward, however input parameters that are derived analytically have historically used uncertainties based on engineering judgment. A MATLAB program was created to use laboratory generated thermogravimetric analysis (TGA) data to calculate uncertainties on the Arrhenius parameters for molded Avcoat. Uncertainties associated with the normalized ablation rate and pyrolysis gas enthalpy were also generated using a wrapper script and the ACE code. These uncertainties could then be tied directly to measured values of individual elemental constituents. The resulting uncertainty values will allow for a probabilistic sizing approach on molded Avcoat with a higher level of confidence in the input parameters

    Slow advancement of enteral feed volumes to prevent necrotising enterocolitis in very low birth weight infants

    Get PDF
    BACKGROUND: Early enteral feeding practices are potentially modifiable risk factors for necrotising enterocolitis (NEC) in very preterm or very low birth weight (VLBW) infants. Observational studies suggest that conservative feeding regimens, including slowly advancing enteral feed volumes, reduce the risk of NEC. However, slow feed advancement may delay establishment of full enteral feeding and may be associated with metabolic and infectious morbidities secondary to prolonged exposure to parenteral nutrition. OBJECTIVES: To determine effects of slow rates of enteral feed advancement on the incidence of NEC, mortality, and other morbidities in very preterm or VLBW infants. SEARCH METHODS: We used the standard Cochrane Neonatal search strategy to search the Cochrane Central Register of Controlled Trials (CENTRAL; 2017, Issue 5), MEDLINE via PubMed (1966 to June 2017), Embase (1980 to June 2017), and the Cumulative Index to Nursing and Allied Health Literature (CINAHL; 1982 to June 2017). We searched clinical trials databases, conference proceedings, previous reviews, and reference lists of retrieved articles for randomised controlled trials (RCTs) and quasi-randomised trials. SELECTION CRITERIA: Randomised or quasi-randomised controlled trials that assessed effects of slow (up to 24 mL/kg/d) versus faster rates of advancement of enteral feed volumes upon the incidence of NEC in very preterm or VLBW infants. DATA COLLECTION AND ANALYSIS: Two review authors assessed trial eligibility and risk of bias and independently extracted data. We analysed treatment effects in individual trials and reported risk ratio (RR) and risk difference (RD) for dichotomous data, and mean difference (MD) for continuous data, with respective 95% confidence intervals (CIs). We used a fixed-effect model for meta-analyses and explored potential causes of heterogeneity via sensitivity analyses. We assessed the quality of evidence at the outcome level using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. MAIN RESULTS: We identified 10 RCTs in which a total of 3753 infants participated (2804 infants participated in one large trial). Most participants were stable very preterm infants of birth weight appropriate for gestation. About one-third of all participants were extremely preterm or extremely low birth weight (ELBW), and about one-fifth were small for gestational age (SGA), growth-restricted, or compromised in utero, as indicated by absent or reversed end-diastolic flow velocity (AREDFV) in the fetal umbilical artery. Trials typically defined slow advancement as daily increments of 15 to 20 mL/kg, and faster advancement as daily increments of 30 to 40 mL/kg. Trials generally were of good methodological quality, although none was blinded.Meta-analyses did not show effects on risk of NEC (typical RR 1.07, 95% CI 0.83 to 1.39; RD 0.0, 95% CI -0.01 to 0.02) or all-cause mortality (typical RR 1.15, 95% CI 0.93 to 1.42; typical RD 0.01, 95% CI -0.01 to 0.03). Subgroup analyses of extremely preterm or ELBW infants, or of SGA or growth-restricted or growth-compromised infants, showed no evidence of an effect on risk of NEC or death. Slow feed advancement delayed establishment of full enteral nutrition by between about one and five days. Meta-analysis showed borderline increased risk of invasive infection (typical RR 1.15, 95% CI 1.00 to 1.32; typical RD 0.03, 95% CI 0.00 to 0.05). The GRADE quality of evidence for primary outcomes was "moderate", downgraded from "high" because of lack of blinding in the included trials. AUTHORS' CONCLUSIONS: Available trial data do not provide evidence that advancing enteral feed volumes at daily increments of 15 to 20 mL/kg (compared with 30 to 40 mL/kg) reduces the risk of NEC or death in very preterm or VLBW infants, extremely preterm or ELBW infants, SGA or growth-restricted infants, or infants with antenatal AREDFV. Advancing the volume of enteral feeds at a slow rate results in several days of delay in establishing full enteral feeds and may increase the risk of invasive infection

    Fiberoptic microtransducer pressure technology: Uurodynamic implications

    Full text link
    The FST 200 is a novel commercially available pressure measurement system that combines microtechnology and fiberoptics and is particularly well suited for invasive urodynamic studies. Pressure recording with this system is highly accurate and reproducible. The pressure curves obtained parallel those from standard water cystometry. Being small and portable, the system lends itself to invasive transurethral monitoring in the privacy of an examination room. Additionally, the 5F catheter size allows the performance of leak point pressures and pressure/flow voiding studies with minimal urethral stenting artifact often seen with larger catheters. The technical aspects of this system are presented.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/38473/1/1930120211_ftp.pd

    An exploration of function analysis and function allocation in the commercial flight domain

    Get PDF
    The applicability is explored of functional analysis methods to support cockpit design. Specifically, alternative techniques are studied for ensuring an effective division of responsibility between the flight crew and automation. A functional decomposition is performed of the commercial flight domain to provide the information necessary to support allocation decisions and demonstrate methodology for allocating functions to flight crew or to automation. The function analysis employed 'bottom up' and 'top down' analyses and demonstrated the comparability of identified functions, using the 'lift off' segment of the 'take off' phase as a test case. The normal flight mission and selected contingencies were addressed. Two alternative methods for using the functional description in the allocation of functions between man and machine were investigated. The two methods were compared in order to ascertain their relative strengths and weaknesses. Finally, conclusions were drawn regarding the practical utility of function analysis methods

    Prebiotics to prevent necrotising enterocolitis in very preterm or very low birth weight infants

    Get PDF
    BACKGROUND: Dietary supplementation with prebiotic oligosaccharides to modulate the intestinal microbiome has been proposed as a strategy to reduce the risk of necrotising enterocolitis (NEC) and associated mortality and morbidity in very preterm or very low birth weight (VLBW) infants. OBJECTIVES: To assess the benefits and harms of enteral supplementation with prebiotics (versus placebo or no treatment) for preventing NEC and associated morbidity and mortality in very preterm or VLBW infants. SEARCH METHODS: We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, the Maternity and Infant Care database and the Cumulative Index to Nursing and Allied Health Literature (CINAHL), from the earliest records to July 2022. We searched clinical trials databases and conference proceedings, and examined the reference lists of retrieved articles. SELECTION CRITERIA: We included randomised controlled trials (RCTs) and quasi-RCTs comparing prebiotics with placebo or no prebiotics in very preterm ( 48 hours after birth) invasive infection, duration of hospitalisation, and neurodevelopmental impairment. We used the GRADE approach to assess the level of certainty of the evidence. MAIN RESULTS: We included seven trials in which a total of 705 infants participated. All the trials were small (mean sample size 100). Lack of clarity on methods to conceal allocation and mask caregivers or investigators were potential sources of bias in three of the trials. The studied prebiotics were fructo- and galacto-oligosaccharides, inulin, and lactulose, typically administered daily with enteral feeds during birth hospitalisation. Meta-analyses of data from seven trials (686 infants) suggest that prebiotics may result in little or no difference in NEC (RR 0.97, 95% CI 0.60 to 1.56; RD none fewer per 1000, 95% CI 50 fewer to 40 more; low-certainty evidence), all-cause mortality (RR 0.43, 95% CI 0.20 to 0.92; 40 per 1000 fewer, 95% CI 70 fewer to none fewer; low-certainty evidence), or late-onset invasive infection (RR 0.79, 95% CI 0.60 to 1.06; 50 per 1000 fewer, 95% CI 100 fewer to 10 more; low-certainty evidence) prior to hospital discharge. The certainty of this evidence is low because of concerns about the risk of bias in some trials and the imprecision of the effect size estimates. The data available from one trial provided only very low-certainty evidence about the effect of prebiotics on measures of neurodevelopmental impairment (Bayley Scales of Infant Development (BSID) Mental Development Index score < 85: RR 0.84, 95% CI 0.25 to 2.90; very low-certainty evidence; BSID Psychomotor Development Index score < 85: RR 0.24, 95% 0.03 to 2.00; very low-certainty evidence; cerebral palsy: RR 0.35, 95% CI 0.01 to 8.35; very low-certainty evidence). AUTHORS' CONCLUSIONS: The available trial data provide low-certainty evidence about the effects of prebiotics on the risk of NEC, all-cause mortality before discharge, and invasive infection, and very low-certainty evidence about the effect on neurodevelopmental impairment for very preterm or VLBW infants. Our confidence in the effect estimates is limited; the true effects may be substantially different. Large, high-quality trials are needed to provide evidence of sufficient validity to inform policy and practice decisions

    A simple flip of an obstetrics clerkship lecture focusing on interactive learning

    Get PDF
    Abstract Objective: To determine the value of interactive learning after a low-tech flip of a traditional lecture during an obstetrics and gynecology clerkship. Design: All third-year medical students completed a flipped learning experience between May 2014 and April 2016. Central to the change was replacement of a mid-clerkship lecture (&quot;late term and prolonged gestation&quot;) with interactive learning at seven stations by student pairs (one each on separate obstetrics and gynecology services). Before class, students electronically received a handout that described learning objectives, subject background, and interactive stations. The stations featured manipulative models, instruments, data, and images involving prenatal care, fetal growth and testing, and labor and delivery decision-making. Results: The flipped model was easily executed with proper preparation. The 178 consecutive students completed the two mandated surveys. The median score given by students about the same instructor&apos;s effectiveness increased from 4.0 (previous two years) to 4.4 (on a 5-point scale). Compared with traditional lectures by other clerkship faculty, the flipped classroom was judged by students to be easier for understanding and more interactive. Students perceived being more responsible for learning with better recall and application to practice. Conclusions: A low-tech approach to the flipped classroom was easily executed with favorable responses from students about interactive learning

    Supramolecular Click Chemistry for Surface Modification of Quantum Dots Mediated by Cucurbit[7]uril

    Get PDF
    Cucurbiturils (CBs), barrel-shaped macrocyclic molecules, are capable of self-assembling at the surface of nanomaterials in their native state, via their carbonyl-ringed portals. However, the symmetrical two-portal structure typically leads to aggregated nanomaterials. We demonstrate that fluorescent quantum dot (QD) aggregates linked with CBs can be broken-up, retaining CBs adsorbed at their surface, via inclusion of guests in the CB cavity. Simultaneously, the QD surface is modified by a functional tail on the guest, thus the high affinity host-guest binding (logKa > 9) enables a non-covalent, click-like modification of the nanoparticles in aqueous solution. We achieved excellent modification efficiency in several functional QD conjugates as protein labels. Inclusion of weaker-binding guests (logKa = 4-6) enables subsequent displacement with stronger binders, realising modular switchable surface chemistries. Our general "hook-and-eye" approach to host-guest chemistry at nanomaterial interfaces will lead to divergent routes for nano-architectures with rich functionalities for theranostics and photonics in aqueous systems
    corecore