5,212 research outputs found

    Erratum: Is it possible to infer the equation of state of a mixture of hard discs from that of the one-component system?

    Full text link
    The numerical values in the sixth and seventh columns of table 1 of the paper Molec. Phys., 1999, 96, 1185-1188 are not correct. Consequently, some of the comments made in the paper are wrong. The corrected version of table 1 is reprinted here and the results are briefly discussed.Comment: 2 pages; Erratum to Molec. Phys., 1999, 96, 1185-1188; to be published in Molec. Phy

    Validation and Improvement of the Beef Production Sub-index in Ireland for Beef Cattle

    Get PDF
    End of project reportThe objectives of the following study were to: a. Quantify the effect of sire genetic merit for BCI on: 1. feed intake, growth and carcass traits of progeny managed under bull or steer beef production systems. 2. live animal scores, carcass composition and plasma hormone and metabolite concentrations in their progeny. b. Compare the progeny of : 1. Late-maturing beef with dairy breeds and 2. Charolais (CH), Limousin (LM), Simmental (SM) and Belgian Blue (BB) sires bred to beef suckler dams, for feed intake, blood hormones and metabolites, live animal measurements, carcass traits and carcass value in bull and steer production systems

    A REVIEW AND CRITIQUE OF DSS

    Get PDF
    Information Systems Working Papers Serie

    Reduced glycogen availability is associated with increased AMPKα2 activity, nuclear AMPKα2 protein abundance, and GLUT4 mRNA expression in contracting human skeletal muscle

    Full text link
    Glycogen availability can influence glucose transporter 4 (GLUT4) expression in skeletal muscle through unknown mechanisms. The multisubstrate enzyme AMP-activated protein kinase (AMPK) has also been shown to play an important role in the regulation of GLUT4 expression in skeletal muscle. During contraction, AMPK [alpha]2 translocates to the nucleus and the activity of this AMPK isoform is enhanced when skeletal muscle glycogen is low. In this study, we investigated if decreased pre-exercise muscle glycogen levels and increased AMPK [alpha]2 activity reduced the association of AMPK with glycogen and increased AMPK [alpha]2 translocation to the nucleus and GLUT4 mRNA expression following exercise. Seven males performed 60 min of exercise at ~70% [VO.sub.2] peak on 2 occasions: either with normal (control) or low (LG) carbohydrate pre-exercise muscle glycogen content. Muscle samples were obtained by needle biopsy before and after exercise. Low muscle glycogen was associated with elevated AMPK [alpha]2 activity and acetyl-CoA carboxylase [beta] phosphorylation, increased translocation of AMPK [alpha]2 to the nucleus, and increased GLUT4 mRNA. Transfection of primary human myotubes with a constitutively active AMPK adenovirus also stimulated GLUT4 mRNA, providing direct evidence of a role of AMPK in regulating GLUT4 expression. We suggest that increased activation of AMPK [alpha]2 under conditions of low muscle glycogen enhances AMPK [alpha]2 nuclear translocation and increases GLUT4 mRNA expression in response to exercise in human skeletal muscle. <br /

    The Stellar Content of Obscured Galactic Giant H II Regions IV.: NGC3576

    Get PDF
    We present deep, high angular resolution near-infrared images of the obscured Galactic Giant H II region NGC3576. Our images reach objects to ~3M_sun. We collected high signal-to-noise K-band spectra of eight of the brightest objects, some of which are affected by excess emission and some which follow a normal interstellar reddening law. None of them displayed photospheric features typical of massive OB type stars. This indicates that they are still enshrouded in their natal cocoons. The K-band brightest source (NGC3576 #48) shows CO 2.3 micron bandhead emission, and three others have the same CO feature in absorption. Three sources display spatially unresolved H_2 emission, suggesting dense shocked regions close to the stars. We conclude that the remarkable object NGC3576 #48 is an early-B/late-O star surrounded by a thick circumstellar disk. A number of other relatively bright cluster members also display excess emission in the K-band, indicative of reprocessing disks around massive stars (YSOs). Such emission appears common in other Galactic Giant H II regions we have surveyed. The IMF slope of the cluster, Gamma = -1.51, is consistent with Salpeter's distribution and similar to what has been observed in the Magellanic Cloud clusters and in the periphery of our Galaxy.Comment: 14 pages, 11 figures, accepted for publication in A

    Enhanced Safety Surveillance of Influenza Vaccines in General Practice, Winter 2015-16: Feasibility Study

    Get PDF
    BACKGROUND: The European Medicines Agency (EMA) requires vaccine manufacturers to conduct enhanced real-time surveillance of seasonal influenza vaccination. The EMA has specified a list of adverse events of interest to be monitored. The EMA sets out 3 different ways to conduct such surveillance: (1) active surveillance, (2) enhanced passive surveillance, or (3) electronic health record data mining (EHR-DM). English general practice (GP) is a suitable setting to implement enhanced passive surveillance and EHR-DM. OBJECTIVE: This study aimed to test the feasibility of conducting enhanced passive surveillance in GP using the yellow card scheme (adverse events of interest reporting cards) to determine if it has any advantages over EHR-DM alone. METHODS: A total of 9 GPs in England participated, of which 3 tested the feasibility of enhanced passive surveillance and the other 6 EHR-DM alone. The 3 that tested EPS provided patients with yellow (adverse events) cards for patients to report any adverse events. Data were extracted from all 9 GPs' EHRs between weeks 35 and 49 (08/24/2015 to 12/06/2015), the main period of influenza vaccination. We conducted weekly analysis and end-of-study analyses. RESULTS: Our GPs were largely distributed across England with a registered population of 81,040. In the week 49 report, 15,863/81,040 people (19.57% of the registered practice population) were vaccinated. In the EPS practices, staff managed to hand out the cards to 61.25% (4150/6776) of the vaccinees, and of these cards, 1.98% (82/4150) were returned to the GP offices. Adverse events of interests were reported by 113 /7223 people (1.56%) in the enhanced passive surveillance practices, compared with 322/8640 people (3.73%) in the EHR-DM practices. CONCLUSIONS: Overall, we demonstrated that GPs EHR-DM was an appropriate method of enhanced surveillance. However, the use of yellow cards, in enhanced passive surveillance practices, did not enhance the collection of adverse events of interests as demonstrated in this study. Their return rate was poor, data entry from them was not straightforward, and there were issues with data reconciliation. We concluded that customized cards prespecifying the EMA's adverse events of interests, combined with EHR-DM, were needed to maximize data collection. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR2-10.1136/bmjopen-2016-015469

    The Effect of Electronic Cigarette User Modifications and E-liquid Adulteration on the Particle Size Profile of an Aerosolized Product

    Get PDF
    Electronic cigarettes (e-cigarettes) are an alternate nicotine delivery system that generate a condensation aerosol to be inhaled by the user. The size of the droplets formed in the aerosol can vary and contributes to drug deposition and ultimate bioavailability in the lung. The growing popularity of e-cigarette products has caused an increase in internet sources promoting the use of drugs other than nicotine (DOTNs) in e-cigarettes. The purpose of this study was to determine the effect of various e-cigarette and e-liquid modifications, such as coil resistance, battery voltage, and glycol and drug formulation, on the aerosol particle size. E-liquids containing 12 mg/mL nicotine prepared in glycol compositions of 100% propylene glycol (PG), 100% vegetable glycerin (VG), or 50:50 PG:VG were aerosolized at three voltages and three coil resistances. Methamphetamine and methadone e-liquids were prepared at 60 mg/mL in 50:50 PG:VG and all e-liquids were aerosolized onto a 10 stage Micro-Orifice Uniform Deposit Impactor. Glycol deposition correlated with drug deposition, and the majority of particles centered between 0.172–0.5 μm in diameter, representing pulmonary deposition. The 100% PG e-liquid produced the largest aerosol particles and the 100% VG and 50:50 PG:VG e-liquids produced ultra-fine particles \u3c0.3 μm. The presence of ultrafine particles indicates that drugs can be aerosolized and reach the pulmonary alveolar regions, highlighting a potential for abuse and risk of overdose with DOTNs aerosolized in an e-cigarette system
    • …
    corecore