5,730 research outputs found

    The design of a gamma‐ray burst polarimeter

    Get PDF
    The study of the polarization properties of the gamma‐ray bursts is the one remaining unexplored avenue of research which may help to answer some of the fundamental problems regarding the nature of these mysterious objects. We have designed an instrument to measure linear polarization in cosmic gamma‐ray bursts at energies ≳50 keV. Here we describe the design of this instrument, which we call the Gamma‐ray Burst Polarimeter Experiment (GRAPE)

    The terminal amino acids of wheat gliadin

    Get PDF
    Wheat gliadin has been found by two different methods to contain three N-terminal histidine residues for each molecular weight of 27,000. Trace amounts of N-terminal aspartic acid, glutamic acid, alanine, valine, and serine were also detected in the preparation used. Hydrolysis in boiling hydrochloric acid partially destroyed the di-2,4-dinitrophenyl derivative of histidine. Losses of from 5% to 25% occurred depending upon the time and conditions of hydrolysis. Carboxypeptidase did not release free amino acids from wheat gliadin but qualitative evidence for the occurrence of C-terminal glutamic acid and C-terminal "leucine" was obtained

    The action of sulpeiuric acid on gliadin: with special reference to the N-Peptpdyl→O-Peptpdyl bond rearrangement

    Get PDF
    Treatment of gliadin with sulphuric acid transposes peptide bonds of serine from the amino to the hydroxyl group. Maximum transposition, 60-70% of the theoretical, occurs when the protein is treated with anhydrous sulphuric acid at 0° C. for 35 hr. No rearrangement was detected at threonine residues. Examination of the peptide material, obtained from the rearranged protein by Elliott's degradation method, indicates apparent "homogeneity". In an alternative scheme for the degradation, nitrous acid deamination of free amino groups was used. The resulting loss in serine content of the protein is direct evidence for the acyl migration of peptide bonds. Incorporation of sulphur and partial disappearance of several amino acids accompany the sulphuric acid treatment. The occurrence of these secondary reactions imposes limitations on the use of sulphuric acid as a reagent for the specific fission of peptide bonds

    The development of a position-sensitive CZT detector with orthogonal co-planar anode strips

    Get PDF
    We report on the simulation, construction, and performance of prototype CdZnTe imaging detectors with orthogonal coplanar anode strips. These detectors employ a novel electrode geometry with non-collecting anode strips in one dimension and collecting anode pixels, interconnected in rows, in the orthogonal direction. These detectors retain the spectroscopic and detection efficiency advantages of single carrier (electron) sensing devices as well as the principal advantage of conventional strip detectors with orthogonal anode and cathode strips, i.e. an N×N array of imaging pixels are with only 2N electronic channels. Charge signals induced on the various electrodes of a prototype detector with 8×8 unit cells (1×1×5 mm3)are compared to the simulations. Results of position and energy resolution measurements are presented and discussed

    COMPTEL observations of the Virgo blazars 3C 273 and 3C 279

    Get PDF
    We report the main MeV properties (detections, light curves, spectra) of the Virgo blazars 3C 273 and 3C 279 which were derived from a consistent analysis of all COMPTEL Virgo observations between 1991 and 1997

    Proprioceptive changes impair balance control in individuals with chronic obstructive pulmonary disease

    Get PDF
    Copyright @ 2013 Janssens et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.Introduction: Balance deficits are identified as important risk factors for falling in individuals with chronic obstructive pulmonary disease (COPD). However, the specific use of proprioception, which is of primary importance during balance control, has not been studied in individuals with COPD. The objective was to determine the specific proprioceptive control strategy during postural balance in individuals with COPD and healthy controls, and to assess whether this was related to inspiratory muscle weakness. Methods: Center of pressure displacement was determined in 20 individuals with COPD and 20 age/gender-matched controls during upright stance on an unstable support surface without vision. Ankle and back muscle vibration were applied to evaluate the relative contribution of different proprioceptive signals used in postural control. Results: Individuals with COPD showed an increased anterior-posterior body sway during upright stance (p=0.037). Compared to controls, individuals with COPD showed an increased posterior body sway during ankle muscle vibration (p=0.047), decreased anterior body sway during back muscle vibration (p=0.025), and increased posterior body sway during simultaneous ankle-muscle vibration (p=0.002). Individuals with COPD with the weakest inspiratory muscles showed the greatest reliance on ankle muscle input when compared to the stronger individuals with COPD (p=0.037). Conclusions: Individuals with COPD, especially those with inspiratory muscle weakness, increased their reliance on ankle muscle proprioceptive signals and decreased their reliance on back muscle proprioceptive signals during balance control, resulting in a decreased postural stability compared to healthy controls. These proprioceptive changes may be due to an impaired postural contribution of the inspiratory muscles to trunk stability. Further research is required to determine whether interventions such as proprioceptive training and inspiratory muscle training improve postural balance and reduce the fall risk in individuals with COPD.This work was supported by the Research Foundation – Flanders (FWO) grants 1.5.104.03, G.0674.09, G.0598.09N and G.0871.13N

    Analog processing of signals from a CZT strip detector with orthogonal coplanar anodes

    Get PDF
    We present the requirements, design, and performance of an analog circuit for processing the non-collecting anode strip signals from a cadmium zinc telluride (CZT) strip detector with orthogonal coplanar anodes. Detector signal simulations and measurements with a prototype are used to define the range of signal characteristics as a function of location of the gamma interaction in the detector. The signals from the non- collecting anode strip electrodes are used to define two of the three spatial coordinates including the depth of interaction, the z dimension. Analog signal processing options are discussed. A circuit to process the signals from the non- collecting anode strips and extract from them the depth of interaction is described. The circuit employs a time-over- threshold (TOT) measurement. The performance of the detector prototype with a preliminary version of this circuit is presented, and future development work is outlined

    COMPTEL observations of the blazars 3C 454.3 and CTA 102

    Get PDF
    We have analyzed the two blazars of 3C 454.3 and CTA 102 using all available COMPTEL data from 1991 to 1999. In the 10–30 MeV band, emission from the general direction of the sources is found at the 4σ-level, being consistent with contributions from both sources. Below 10 MeV only 3C 454.3 is significantly detected, with the strongest evidence (5.6 σ) in the 3–10 MeV band. Significant flux variability is not observed for both sources, while a low emission is seen most of the years in the 3–10 MeV light curve for 3C 454.3. Its time-averaged MeV spectrum suggests a power maximum between 3 to 10 MeV

    Progress in the study of CdZnTe strip detectors

    Get PDF
    We report new performance measurements and computer simulations of a sub-millimeter pitch CdZnTe strip detector under study as a prototype imaging spectrometer for astronomical x-ray and gamma-ray observations. The prototype is 1.5 mm thick with 375 micron strip pitch in both the x and y dimensions. Previously reported work included demonstrations of half-pitch spatial resolution (approximately 190 microns) and good energy resolution and spectral uniformity. Strip detector efficiency measurements have also been presented. A model that includes the photon interaction, carrier transport and the electronics was developed that qualitatively reproduced the measurements. The new studies include measurements of the CdZnTe transport properties for this prototype in an effort to resolve quantitative discrepancies between the measurements and the simulations. Measurements of charge signals produced by laser pulses and (alpha) -rays are used to determine these transport properties. These are then used in the model to predict gamma-ray efficiencies that are compared with the data. The imaging performance of the detector is studied by scanned laser and gamma beam spot measurements. The results support the model\u27s prediction of nearly linear sharing of the charge for interactions occurring in the region between electrodes. The potential for strip detectors with spatial resolution much finer than the strip pitch is demonstrated. A new design scheme for strip detectors is shortly discussed
    corecore