5,161 research outputs found

    Network sensitivity to geographical configuration

    Get PDF
    Gravitational wave astronomy will require the coordinated analysis of data from the global network of gravitational wave observatories. Questions of how to optimally configure the global network arise in this context. We have elsewhere proposed a formalism which is employed here to compare different configurations of the network, using both the coincident network analysis method and the coherent network analysis method. We have constructed a network model to compute a figure-of-merit based on the detection rate for a population of standard-candle binary inspirals. We find that this measure of network quality is very sensitive to the geographic location of component detectors under a coincident network analysis, but comparatively insensitive under a coherent network analysis.Comment: 7 pages, 4 figures, accepted for proceedings of the 4th Edoardo Amaldi conference, incorporated referees' suggestions and corrected diagra

    The ACIGA Data Analysis programme

    Full text link
    The Data Analysis programme of the Australian Consortium for Interferometric Gravitational Astronomy (ACIGA) was set up in 1998 by the first author to complement the then existing ACIGA programmes working on suspension systems, lasers and optics, and detector configurations. The ACIGA Data Analysis programme continues to contribute significantly in the field; we present an overview of our activities.Comment: 10 pages, 0 figures, accepted, Classical and Quantum Gravity, (Proceedings of the 5th Edoardo Amaldi Conference on Gravitational Waves, Tirrenia, Pisa, Italy, 6-11 July 2003

    Challenges in the registration of serial CT images from lung radiotherapy patients

    Get PDF
    Radiation induced lung damage is an unwanted side effect of curative radiotherapy. Radiological findings are often used as indicators of lung damage, which is identifiable as changes in the baseline imaging features (e.g., anatomy shape, intensity and texture). In this work we qualitatively investigate the challenges in registering baseline and followup CT images acquired 12 months after radiotherapy

    Autoadaptive motion modelling for MR-based respiratory motion estimation

    Get PDF
    © 2016 The Authors.Respiratory motion poses significant challenges in image-guided interventions. In emerging treatments such as MR-guided HIFU or MR-guided radiotherapy, it may cause significant misalignments between interventional road maps obtained pre-procedure and the anatomy during the treatment, and may affect intra-procedural imaging such as MR-thermometry. Patient specific respiratory motion models provide a solution to this problem. They establish a correspondence between the patient motion and simpler surrogate data which can be acquired easily during the treatment. Patient motion can then be estimated during the treatment by acquiring only the simpler surrogate data.In the majority of classical motion modelling approaches once the correspondence between the surrogate data and the patient motion is established it cannot be changed unless the model is recalibrated. However, breathing patterns are known to significantly change in the time frame of MR-guided interventions. Thus, the classical motion modelling approach may yield inaccurate motion estimations when the relation between the motion and the surrogate data changes over the duration of the treatment and frequent recalibration may not be feasible.We propose a novel methodology for motion modelling which has the ability to automatically adapt to new breathing patterns. This is achieved by choosing the surrogate data in such a way that it can be used to estimate the current motion in 3D as well as to update the motion model. In particular, in this work, we use 2D MR slices from different slice positions to build as well as to apply the motion model. We implemented such an autoadaptive motion model by extending our previous work on manifold alignment.We demonstrate a proof-of-principle of the proposed technique on cardiac gated data of the thorax and evaluate its adaptive behaviour on realistic synthetic data containing two breathing types generated from 6 volunteers, and real data from 4 volunteers. On synthetic data the autoadaptive motion model yielded 21.45% more accurate motion estimations compared to a non-adaptive motion model 10 min after a change in breathing pattern. On real data we demonstrated the methods ability to maintain motion estimation accuracy despite a drift in the respiratory baseline. Due to the cardiac gating of the imaging data, the method is currently limited to one update per heart beat and the calibration requires approximately 12 min of scanning. Furthermore, the method has a prediction latency of 800 ms. These limitations may be overcome in future work by altering the acquisition protocol

    Stabilization of injection-locked lasers using spatial mode interference

    Get PDF
    We report the use of spatial-mode-interference, or tilt-locking, for the active stabilization of injection-locking of a Nd:YAG laser. We show that this control scheme is robust and adds negligible frequency noise to the injection-locked laserOttaway, D.J.; Gray, M.B.; Shaddock, D.A.; Hollitt, C.; Veitch, P.J.; Munch, J.; McClelland, David Ernes

    Analysis of pre-residency research productivity, dual degree status, and gender distribution of underrepresented minorities among a current United States radiation oncology junior resident class

    Get PDF
    Background: Among the most competitive medical subspecialties, representation of underrepresented minorities (African-American race and/or Hispanic ethnicity) among resident trainees has historically been low compared to their United States Census general population representation. Research productivity and dual degree status may impact residency applicant competitiveness. To date, such an analysis has yet to be performed in Radiation Oncology. Methods: A list of radiation oncology residents from the graduating class of 2022 was obtained through internet searches. Demographics included were gender and dual degree status. Research productivity was calculated using the number of pre-residency peer-reviewed publications (PRP). Fisher's exact test was used for statistical analysis. Results: Of the 179 residents evaluated from the 2022 class, eleven (6.1%) were underrepresented minorities. Compared to the remainder of the class, underrepresented minorities had a lower proportion of men (63.6% versus 69.3%), a higher proportion of dual degrees (45.5% versus 28.6%), and a lower proportion of MD-PhD degrees (9.1% versus 17.2%). Underrepresented minorities had a higher proportion of residents with at least two PRP (72.7% versus 57.1%) and a lower proportion of residents with no PRP (18.2% versus 24.4%). None of these differences reached statistical significance (p > 0.05). Conclusion: Underrepresented minorities were comparable to the remainder of their Radiation Oncology resident class regarding gender distribution, dual degrees status, and likelihood of having at least two peer-reviewed publications cited in PubMed during the calendar year of residency application. Further studies will be needed to determine how these findings translate into future scholarly activity and post-graduate career choice

    A multichannel feature-based approach for longitudinal lung CT registration in the presence of radiation induced lung damage

    Get PDF
    Quantifying parenchymal tissue changes in the lungs is imperative in furthering the study of radiation-induced lung damage (RILD). Registering lung images from different time-points is a key step of this process. Traditional intensity-based registration approaches fail this task due to the considerable anatomical changes that occur between timepoints. This work proposes a novel method to successfully register longitudinal pre- and post-radiotherapy (RT) lung CT scans that exhibit large changes due to RILD, by extracting consistent anatomical features from CT (lung boundaries, main airways, vessels) and using these features to optimise the registrations. Pre-RT and 12-month post-RT CT pairs from fifteen lung cancer patients were used for this study, all with varying degrees of RILD, ranging from mild parenchymal change to extensive consolidation and collapse. For each CT, signed distance transforms from segmentations of the lungs and main airways were generated, and the Frangi vesselness map was calculated. These were concatenated into multi-channel images and diffeomorphic multichannel registration was performed for each image pair using NiftyReg. Traditional intensity-based registrations were also performed for comparison purposes. For the evaluation, the pre- and post-registration landmark distance was calculated for all patients, using an average of 44 manually identified landmark pairs per patient. The mean (standard deviation) distance for all datasets decreased from 15.95 (8.09) mm pre-registration to 4.56 (5.70) mm post-registration, compared to 7.90 (8.97) mm for the intensity-based registrations. Qualitative improvements in image alignment were observed for all patient datasets. For four representative subjects, registrations were performed for 3 additional follow-up timepoints up to 48-months post-RT and similar accuracy was achieved. We have demonstrated that our novel multichannel registration method can successfully align longitudinal scans from RILD patients in the presence of large anatomical changes such as consolidation and atelectasis, outperforming the traditional registration approach both quantitatively and through thorough visual inspection

    Compensation of Strong Thermal Lensing in High Optical Power Cavities

    Get PDF
    In an experiment to simulate the conditions in high optical power advanced gravitational wave detectors such as Advanced LIGO, we show that strong thermal lenses form in accordance with predictions and that they can be compensated using an intra-cavity compensation plate heated on its cylindrical surface. We show that high finesse ~1400 can be achieved in cavities with internal compensation plates, and that the cavity mode structure can be maintained by thermal compensation. It is also shown that the measurements allow a direct measurement of substrate optical absorption in the test mass and the compensation plate.Comment: 8 page

    Coating-free mirrors for high precision interferometric experiments

    No full text
    Thermal noise in mirror optical coatings may not only limit the sensitivity of future gravitational-wave detectors in their most sensitive frequency band but is also a major impediment for experiments that aim to reach the standard quantum limit or cool mechanical systems to their quantum ground state. We present the design and experimental characterization of a highly reflecting mirror without any optical coating. This coating-free mirror is based on total internal reflection and Brewster-angle coupling. In order to characterize its performance, the coating-free mirror was incorporated into a triangular ring cavity together with a high quality conventional mirror. The finesse of this cavity was measured using an amplitude transfer function to be about F≃4000. This finesse corresponds to a reflectivity of the coating-free mirror of about R≃99.89%. In addition, the dependence of the reflectivity on rotation was mapped out
    • …
    corecore