367 research outputs found

    Brief of Constitutional Law Scholars as Amici Curiae in Support of Petitioners

    Get PDF
    Lurking behind the regulatory issues presented by this appeal is a concerted effort to displace the Religious Freedom Restoration Act, 42 U.S.C. § 2000bb et seq. ( RFRA ), with a novel approach that would trivialize a law\u27s burden on religion. The Court should not indulge it. The critics\u27 argument suffers from several analytical defects that can be remedied by (1) a proper constitutional understanding of RFRA\u27s relationship to the Establishment Clause; (2) an accurate understanding of how the Religion Clauses safeguard third-party interests; and (3) the correct application of these understandings to the Final Rules

    Products as Affective Modifiers of Identities

    Full text link
    © The Author(s) 2015. Are salesclerks seen as better, more powerful, or more active when they drive Mustangs? What about entrepreneurs? What about driving a mid-sized car? Intuitively, we have ideas about these, but much of the research on the affective nature of products is on purchasing, desires, and self-fulfillment. Drawing on symbolic interactionism, we argue that people's association with products has some basis in the impression management of their identity. For this to occur, there must be some cultural consensus about the way that products modify identities. Drawing on affect control theory's (ACT) methodology and equations, we measure the goodness, powerfulness, and activeness of several products, identities, and the associated product-modified identities to explore how products function as affective modifiers of identities. We find consistent effects across several types of technology products, whereby products pull the modified identity in the direction of the products' affective qualities. Support is established for the ACT equations that predict how traits modify identities as also having utility for predicting how products modify identities. This suggests that the opening questions can be answered empirically by measuring cultural-specific sentiments of the identity and the product and by developing equations to predict the identity modification process

    Low frequency of the TIRAP S180L polymorphism in Africa, and its potential role in malaria, sepsis, and leprosy

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The Toll-like receptors (TLRs) mediate innate immunity to various pathogens. A mutation (S180L) in the TLR downstream signal transducer <it>TIRAP </it>has recently been reported to be common in Europeans and Africans and to roughly half the risks of heterogeneous infectious diseases including malaria, tuberculosis, bacteremia, and invasive pneumococal disease in heterozygous mutation carriers.</p> <p>Methods</p> <p>We assessed the <it>TIRAP </it>S180L variant by melting curve and RFLP analysis in 1095 delivering women from malaria-endemic Ghana, as well as in a further 1114 individuals participating in case control studies on sepsis and leprosy in Germany, Turkey and Bangladesh.</p> <p>Results</p> <p>In Ghana, the <it>TIRAP </it>S180L polymorphism was virtually absent. In contrast, the mutation was observed among 26.6%, 32.9% and 12% of German, Bangladesh and Turkish controls, respectively. No significant association of the heterozygous genotype with sepsis or leprosy was observed. Remarkably, homozygous <it>TIRAP </it>180L tend to increase the risk of sepsis in the German study (<it>P </it>= 0.04).</p> <p>Conclusion</p> <p>A broad protective effect of <it>TIRAP </it>S180L against infectious diseases <it>per se </it>is not discernible.</p

    Dynamic contrast-enhanced CT compared with positron emission tomography CT to characterise solitary pulmonary nodules: the SPUtNIk diagnostic accuracy study and economic modelling

    Get PDF
    BACKGROUND: Current pathways recommend positron emission tomography-computerised tomography for the characterisation of solitary pulmonary nodules. Dynamic contrast-enhanced computerised tomography may be a more cost-effective approach. OBJECTIVES: To determine the diagnostic performances of dynamic contrast-enhanced computerised tomography and positron emission tomography-computerised tomography in the NHS for solitary pulmonary nodules. Systematic reviews and a health economic evaluation contributed to the decision-analytic modelling to assess the likely costs and health outcomes resulting from incorporation of dynamic contrast-enhanced computerised tomography into management strategies. DESIGN: Multicentre comparative accuracy trial. SETTING: Secondary or tertiary outpatient settings at 16 hospitals in the UK. PARTICIPANTS: Participants with solitary pulmonary nodules of ≥ 8 mm and of ≤ 30 mm in size with no malignancy in the previous 2 years were included. INTERVENTIONS: Baseline positron emission tomography-computerised tomography and dynamic contrast-enhanced computer tomography with 2 years' follow-up. MAIN OUTCOME MEASURES: Primary outcome measures were sensitivity, specificity and diagnostic accuracy for positron emission tomography-computerised tomography and dynamic contrast-enhanced computerised tomography. Incremental cost-effectiveness ratios compared management strategies that used dynamic contrast-enhanced computerised tomography with management strategies that did not use dynamic contrast-enhanced computerised tomography. RESULTS: A total of 380 patients were recruited (median age 69 years). Of 312 patients with matched dynamic contrast-enhanced computer tomography and positron emission tomography-computerised tomography examinations, 191 (61%) were cancer patients. The sensitivity, specificity and diagnostic accuracy for positron emission tomography-computerised tomography and dynamic contrast-enhanced computer tomography were 72.8% (95% confidence interval 66.1% to 78.6%), 81.8% (95% confidence interval 74.0% to 87.7%), 76.3% (95% confidence interval 71.3% to 80.7%) and 95.3% (95% confidence interval 91.3% to 97.5%), 29.8% (95% confidence interval 22.3% to 38.4%) and 69.9% (95% confidence interval 64.6% to 74.7%), respectively. Exploratory modelling showed that maximum standardised uptake values had the best diagnostic accuracy, with an area under the curve of 0.87, which increased to 0.90 if combined with dynamic contrast-enhanced computerised tomography peak enhancement. The economic analysis showed that, over 24 months, dynamic contrast-enhanced computerised tomography was less costly (£3305, 95% confidence interval £2952 to £3746) than positron emission tomography-computerised tomography (£4013, 95% confidence interval £3673 to £4498) or a strategy combining the two tests (£4058, 95% confidence interval £3702 to £4547). Positron emission tomography-computerised tomography led to more patients with malignant nodules being correctly managed, 0.44 on average (95% confidence interval 0.39 to 0.49), compared with 0.40 (95% confidence interval 0.35 to 0.45); using both tests further increased this (0.47, 95% confidence interval 0.42 to 0.51). LIMITATIONS: The high prevalence of malignancy in nodules observed in this trial, compared with that observed in nodules identified within screening programmes, limits the generalisation of the current results to nodules identified by screening. CONCLUSIONS: Findings from this research indicate that positron emission tomography-computerised tomography is more accurate than dynamic contrast-enhanced computerised tomography for the characterisation of solitary pulmonary nodules. A combination of maximum standardised uptake value and peak enhancement had the highest accuracy with a small increase in costs. Findings from this research also indicate that a combined positron emission tomography-dynamic contrast-enhanced computerised tomography approach with a slightly higher willingness to pay to avoid missing small cancers or to avoid a 'watch and wait' policy may be an approach to consider. FUTURE WORK: Integration of the dynamic contrast-enhanced component into the positron emission tomography-computerised tomography examination and the feasibility of dynamic contrast-enhanced computerised tomography at lung screening for the characterisation of solitary pulmonary nodules should be explored, together with a lower radiation dose protocol

    Pan-Cancer Analysis of lncRNA Regulation Supports Their Targeting of Cancer Genes in Each Tumor Context

    Get PDF
    Long noncoding RNAs (lncRNAs) are commonly dys-regulated in tumors, but only a handful are known toplay pathophysiological roles in cancer. We inferredlncRNAs that dysregulate cancer pathways, onco-genes, and tumor suppressors (cancer genes) bymodeling their effects on the activity of transcriptionfactors, RNA-binding proteins, and microRNAs in5,185 TCGA tumors and 1,019 ENCODE assays.Our predictions included hundreds of candidateonco- and tumor-suppressor lncRNAs (cancerlncRNAs) whose somatic alterations account for thedysregulation of dozens of cancer genes and path-ways in each of 14 tumor contexts. To demonstrateproof of concept, we showed that perturbations tar-geting OIP5-AS1 (an inferred tumor suppressor) andTUG1 and WT1-AS (inferred onco-lncRNAs) dysre-gulated cancer genes and altered proliferation ofbreast and gynecologic cancer cells. Our analysis in-dicates that, although most lncRNAs are dysregu-lated in a tumor-specific manner, some, includingOIP5-AS1, TUG1, NEAT1, MEG3, and TSIX, synergis-tically dysregulate cancer pathways in multiple tumorcontexts

    Genomic, Pathway Network, and Immunologic Features Distinguishing Squamous Carcinomas

    Get PDF
    This integrated, multiplatform PanCancer Atlas study co-mapped and identified distinguishing molecular features of squamous cell carcinomas (SCCs) from five sites associated with smokin
    • …
    corecore