867 research outputs found

    MIMAC : Detection of low energy recoils for Dark Matter search

    Full text link
    The MIMAC project is based on a matrix of Micro Time Projection Chambers (micro-TPC) for Dark Matter search, filled with He3 or CF4 and using ionization and tracks. The first measurement of the energy resolution of this micro-TPC is presented as well as its low thresholdComment: Dark Energy and Dark Matter conference, Lyon : France (2008

    MIMAC : a micro-TPC detector for non-baryonic dark matter search

    Full text link
    The MIMAC project is multi-chamber detector for Dark Matter search, aiming at measuring both track and ionization with a matrix of micromegas micro-TPC filled with He3 and CF4. Recent experimental results on the first measurements of the Helium quenching factor at low energy (1 keV recoil) are presented.Comment: 7 pages, Proc of Dark Energy and Dark Matter conference, Lyon : France (2008

    Hilbert Lattice Equations

    Full text link
    There are five known classes of lattice equations that hold in every infinite dimensional Hilbert space underlying quantum systems: generalised orthoarguesian, Mayet's E_A, Godowski, Mayet-Godowski, and Mayet's E equations. We obtain a result which opens a possibility that the first two classes coincide. We devise new algorithms to generate Mayet-Godowski equations that allow us to prove that the fourth class properly includes the third. An open problem related to the last class is answered. Finally, we show some new results on the Godowski lattices characterising the third class of equations.Comment: 24 pages, 3 figure

    A project of a new detector for direct Dark Matter search: MACHe3

    Full text link
    MACHe3 (MAtrix of Cells of superfluid He3) is a project of a new detector for direct Dark Matter (DM) search. A cell of superfluid He3 has been developed and the idea of using a large number of such cells in a high granularity detector is proposed.This contribution presents, after a brief description of the superfluid He3 cell, the simulation of the response of different matrix configurations allowing to define an optimum design as a function of the number of cells and the volume of each cell. The exclusion plot and the predicted interaction cross-section for the neutralino as a photino are presented.Comment: 8 pages, 7 figures, Proceedings of Dark Matter 2000 (Marina Del Rey, Los Angeles, USA, 02/23/2000-02/25/2000

    Thigh fat and muscle each contribute to excess cardiometabolic risk in South Asians, independent of visceral adipose tissue.

    Get PDF
    OBJECTIVE: To compare fat distribution and associations between fat depots and cardiometabolic traits in South Asians and Europeans. METHODS: Five hundred and fourteen South Asians and 669 Europeans, aged 56-86. Questionnaires, record review, blood testing, and coronary artery calcification scores provided diabetes and clinical plus subclinical coronary heart disease (CHD) diagnoses. Abdominal visceral (VAT) and subcutaneous adipose tissue, thigh subcutaneous adipose tissue (TSAT), intermuscular and intramuscular thigh fat and thigh muscle were measured by CT. RESULTS: Accounting for body size, South Asians had greater VAT and TSAT than Europeans, but less thigh muscle. Associations between depots and disease were stronger in South Asians than Europeans. In multivariable analyses in South Asians, VAT was positively associated with diabetes and CHD, while TSAT and thigh muscle were protective for diabetes, and thigh muscle for CHD. Differences in VAT and thigh muscle only partially explained the excess diabetes and CHD in South Asians versus Europeans. Insulin resistance did not account for the effects of TSAT or thigh muscle. CONCLUSIONS: Greater VAT and TSAT and lesser thigh muscle in South Asians contributed to ethnic differences in cardiometabolic disease. Effects of TSAT and thigh muscle were independent of insulin resistance

    Evidence that conflict regarding size of haemodynamic response to interventricular delay optimization of cardiac resynchronization therapy may arise from differences in how atrioventricular delay is kept constant.

    Get PDF
    Aims: Whether adjusting interventricular (VV) delay changes haemodynamic efficacy of cardiac resynchronization therapy (CRT) is controversial, with conflicting results. This study addresses whether the convention for keeping atrioventricular (AV) delay constant during VV optimization might explain these conflicts. / Method and results: Twenty-two patients in sinus rhythm with existing CRT underwent VV optimization using non-invasive systolic blood pressure. Interventricular optimization was performed with four methods for keeping the AV delay constant: (i) atrium and left ventricle delay kept constant, (ii) atrium and right ventricle delay kept constant, (iii) time to the first-activated ventricle kept constant, and (iv) time to the second-activated ventricle kept constant. In 11 patients this was performed with AV delay of 120 ms, and in 11 at AV optimum. At AV 120 ms, time to the first ventricular lead (left or right) was the overwhelming determinant of haemodynamics (13.75 mmHg at ±80 ms, P < 0.001) with no significant effect of time to second lead (0.47 mmHg, P = 0.50), P < 0.001 for difference. At AV optimum, time to first ventricular lead again had a larger effect (5.03 mmHg, P < 0.001) than time to second (2.92 mmHg, P = 0.001), P = 0.02 for difference. / Conclusion: Time to first ventricular activation is the overwhelming determinant of circulatory function, regardless of whether this is the left or right ventricular lead. If this is kept constant, the effect of changing time to the second ventricle is small or nil, and is not beneficial. In practice, it may be advisable to leave VV delay at zero. Specifying how AV delay is kept fixed might make future VV delay research more enlightening

    Electron - nuclear recoil discrimination by pulse shape analysis

    Full text link
    In the framework of the ``ULTIMA'' project, we use ultra cold superfluid 3He bolometers for the direct detection of single particle events, aimed for a future use as a dark matter detector. One parameter of the pulse shape observed after such an event is the thermalization time constant. Until now it was believed that this parameter only depends on geometrical factors and superfluid 3He properties, and that it is independent of the nature of the incident particles. In this report we show new results which demonstrate that a difference for muon- and neutron events, as well as events simulated by heater pulses exist. The possibility to use this difference for event discrimination in a future dark matter detector will be discussed.Comment: Proseedings of QFS 2007, Kazan, Russia; 8 pages, 4 figures. Submited to J. Low Temp. Phy

    Three-dimensional track reconstruction for directional Dark Matter detection

    Full text link
    Directional detection of Dark Matter is a promising search strategy. However, to perform such detection, a given set of parameters has to be retrieved from the recoiling tracks : direction, sense and position in the detector volume. In order to optimize the track reconstruction and to fully exploit the data of forthcoming directional detectors, we present a likelihood method dedicated to 3D track reconstruction. This new analysis method is applied to the MIMAC detector. It requires a full simulation of track measurements in order to compare real tracks to simulated ones. We conclude that a good spatial resolution can be achieved, i.e. sub-mm in the anode plane and cm along the drift axis. This opens the possibility to perform a fiducialization of directional detectors. The angular resolution is shown to range between 20^\circ to 80^\circ, depending on the recoil energy, which is however enough to achieve a high significance discovery of Dark Matter. On the contrary, we show that sense recognition capability of directional detectors depends strongly on the recoil energy and the drift distance, with small efficiency values (50%-70%). We suggest not to consider this information either for exclusion or discovery of Dark Matter for recoils below 100 keV and then to focus on axial directional data.Comment: 27 pages, 20 figure

    Probing neutralino dark matter in the MSSM & the NMSSM with directional detection

    Full text link
    We investigate the capability of directional detectors to probe neutralino dark matter in the Minimal Supersymmetric Standard Model and the Next-to-Minimal Supersymmetric Standard Model with parameters defined at the weak scale. We show that directional detectors such as the future MIMAC detector will probe spin dependent dark matter scattering on nucleons that are beyond the reach of current spin independent detectors. The complementarity between indirect searches, in particular using gamma rays from dwarf spheroidal galaxies, spin dependent and spin independent direct search techniques is emphasized. We comment on the impact of the negative results on squark searches at the LHC. Finally, we investigate how the fundamental parameters of the models can be constrained in the event of a dark matter signal.Comment: 21 pages, 16 figure
    corecore