15,415 research outputs found

    Dodecahedral topology fails to explain quadrupole-octupole alignment

    Full text link
    The CMB quadrupole and octupole, as well as being weaker than expected, align suspiciously well with each other. Non-trivial spatial topology can explain the weakness. Might it also explain the alignment? The answer, at least in the case of the Poincare dodecahedral space, is a resounding no.Comment: 5 pages, 1 figur

    Comment on "Perfect imaging with positive refraction in three dimensions"

    Full text link
    Leonhard and Philbin [Phys. Rev. A 81, 011804(R) (2010)] have recently constructed a mathematical proof that the Maxwell's fish-eye lens provides perfect imaging of electromagnetic waves without negative refraction. In this comment, we argue that the unlimited resolution is an artifact of having introduced an unphysical drain at the position of the geometrical image. The correct solution gives focusing consistent with the standard diffraction limit

    The practical implementation of fatigue requirements to military aircraft and helicopters in the United Kingdom

    Get PDF
    The methods adopted in the United Kingdom to ensure the structural integrity of military aeroplanes and helicopters from the fatigue point of view are described. The procedure adopted from the writing of the specification to the monitoring of fatigue life in service are presented along with the requirements to be met and the way in which they are satisfied. Some of the outstanding problems that remain to be solved are indicated

    Single-shot electro-optic sampling of coherent transition radiation at the A0 Photoinjector

    Full text link
    Future collider applications and present high-gradient laser plasma wakefield accelerators operating with picosecond bunch durations place a higher demand on the time resolution of bunch distribution diagnostics. This demand has led to significant advancements in the field of electro-optic sampling over the past ten years. These methods allow the probing of diagnostic light such as coherent transition radiation or the bunch wakefields with sub-picosecond time resolution. Potential applications in shot-to-shot, non-interceptive diagnostics continue to be pursued for live beam monitoring of collider and pump-probe experiments. Related to our developing work with electro-optic imaging, we present results on single-shot electro-optic sampling of the coherent transition radiation from bunches generated at the A0 photoinjector.Comment: 3 p

    Speciation without chromatography: Part I. Determination of tributyltin in aqueous samples by chloride generation, headspace solid-phase microextraction and inductively coupled plasma time of flight mass spectrometry

    Get PDF
    An analytical procedure was developed for the determination of tributyltin in aqueous samples. The relatively high volatility of the organometal halide species confers suitability for their headspace sampling from the vapour phase above natural waters or leached solid samples. Tributyltin was collected from the sample headspace above various chloride-containing matrices, including HCl, sodium chloride solution and sea-water, by passive sampling using a polydimethylsiloxane/divinylbenzene (PDMS/DVB)-coated solid-phase microextraction (SPME) fiber. Inductively coupled plasma time-of-flight mass spectrometry (ICP-TOFMS) was used for detection following thermal desorption of analytes from the fiber. A detection limit of 5.8 pg ml–1(as tin) was realized in aqueous samples. Method validation was achieved using NRCC PACS-2 (Sediment) certified reference material, for which reasonable agreement between certified and measured values for tributyltin content was obtained

    A model problem for conformal parameterizations of the Einstein constraint equations

    Full text link
    We investigate the possibility that the conformal and conformal thin sandwich (CTS) methods can be used to parameterize the set of solutions of the vacuum Einstein constraint equations. To this end we develop a model problem obtained by taking the quotient of certain symmetric data on conformally flat tori. Specializing the model problem to a three-parameter family of conformal data we observe a number of new phenomena for the conformal and CTS methods. Within this family, we obtain a general existence theorem so long as the mean curvature does not change sign. When the mean curvature changes sign, we find that for certain data solutions exist if and only if the transverse-traceless tensor is sufficiently small. When such solutions exist, there are generically more than one. Moreover, the theory for mean curvatures changing sign is shown to be extremely sensitive with respect to the value of a coupling constant in the Einstein constraint equations.Comment: 40 pages, 4 figure

    Programmable telemetry system Patent

    Get PDF
    Time division multiplexed telemetry transmitting system controlled by programmed memor
    • …
    corecore