4 research outputs found

    Sonometric assessment of cough predicts extubation failure: SonoWean—a proof-of-concept study

    No full text
    Abstract Background Extubation failure is associated with increased mortality. Cough ineffectiveness may be associated with extubation failure, but its quantification for patients undergoing weaning from invasive mechanical ventilation (IMV) remains challenging. Methods Patients under IMV for more than 24 h completing a successful spontaneous T-tube breathing trial (SBT) were included. At the end of the SBT, we performed quantitative sonometric assessment of three successive coughing efforts using a sonometer. The mean of the 3-cough volume in decibels was named Sonoscore. Results During a 1-year period, 106 patients were included. Median age was 65 [51–75] years, mainly men (60%). Main reasons for IMV were acute respiratory failure (43%), coma (25%) and shock (17%). Median duration of IMV at enrollment was 4 [3–7] days. Extubation failure occurred in 15 (14%) patients. Baseline characteristics were similar between success and failure extubation groups, except percentage of simple weaning which was lower and MV duration which was longer in extubation failure patients. Sonoscore was significantly lower in patients who failed extubation (58 [52–64] vs. 75 [70–78] dB, P < 0.001). After adjustment on MV duration and comorbidities, Sonoscore remained associated with extubation failure. Sonoscore was predictive of extubation failure with an area under the ROC curve of 0.91 (IC95% [0.83–0.99], P < 0.001). A threshold of Sonoscore < 67.1 dB predicted extubation failure with a sensitivity of 0.93 IC95% [0.70–0.99] and a specificity of 0.82 IC95% [0.73–0.90]. Conclusion Sonometric assessment of cough strength might be helpful to identify patients at risk of extubation failure in patients undergoing IMV

    Improvement of central vein ultrasound-guided puncture success using a homemade needle guide—a simulation study

    No full text
    Abstract Background Out-of-plane (OOP) approach is frequently used for ultrasound-guided insertion of central venous catheter (CVC) owing to its simplicity but does not avoid mechanical complication. In-plane (IP) approach might improve safety of insertion; however, it is less easy to master. We assessed, a homemade needle guide device aimed to improve CVC insertion using IP approach. Method We evaluated in a randomized simulation trial, the impact of a homemade needle guide on internal jugular, subclavian and femoral vein puncture, using three approaches: out-of-plane free hand (OOP-FH), in-plane free hand (IP-FH), and in-plane needle guided (IP-NG). Success at first pass, the number of needle redirections and arterial punctures was recorded. Time elapsed (i) from skin contact to first skin puncture, (ii) from skin puncture to successful venous puncture and (iii) from skin contact to venous return were measured. Results Thirty operators performed 270 punctures. IP-NG approach resulted in high success rate at first pass (jugular: 80%, subclavian: 95% and femoral: 100%) which was higher than success rate observed with OOP-FH and IP-FH regardless of the site (p = .01). Compared to IP-FH and OOP-FH, the IP-NG approach decreased the number of needle redirections at each site (p = .009) and arterial punctures (p = .001). Compared to IP-FH, the IP-NG approach decreased the total procedure duration for puncture at each site. Conclusion In this simulation study, IP approach using a homemade needle guide for ultrasound-guided central vein puncture improved success rate at first pass, reduced the number of punctures/redirections and shortened the procedure duration compared to OOP and IP free-hand approaches

    Prediction of esophagogastroduodenoscopy therapeutic usefulness for in-ICU suspected upper gastrointestinal bleeding: the SUGIBI score study

    No full text
    International audienceBackground: Suspected upper gastrointestinal bleeding (SUGIB) is a common issue during ICU stay. In the absence of specific guidelines on the indication and timing of esophagogastroduodenoscopy (EGD), there is substantial variability in EGD indication depending on accessibility and clinical presentation. This study aimed to investigate factors associated with the need for per-EGD hemostatic therapy and to create a score predicting therapeutic benefit of emergency bedside EGD in ICU patients with SUGIB. Methods: We conducted a retrospective study in our ICU to identify factors associated with the need for hemostatic procedure during EGD performed for SUGIB. From this observational cohort, we derived a score predicting the need for hemostasis during EGD, the SUGIBI score. This score was subsequently validated in a retrospective multicenter cohort. Results: Two hundred fifty-five patients not primarily admitted for GI bleeding who underwent a bedside EGD for SUGIB during their ICU stay were analyzed. The preeminent EGD indication were anemia (79%), melena (19%), shock (14%), and hematemesis (13%). EGD was normal in 24.7% of cases, while primary lesions reported were ulcers (23.1%), esophagitis (18.8%), and gastritis (12.5%). Only 12.9% of patients underwent hemostatic endotherapy during EGD. A SUGIBI score Conclusions Our study shows that the therapeutic usefulness of bedside emergency EGD for SUGIB in critically ill patients is limited to a minority of patients. The SUGIBI score should help clinicians stratify the probability of a therapeutic EGD

    Additional file 1 of Sonometric assessment of cough predicts extubation failure: SonoWean—a proof-of-concept study

    No full text
    Additional file 1. Supplemental Fig 1: Description of the Pulsar Model 14Âź Sound Level Meter and method for measurement. The Model 14 is a general purpose digital sound level meter which meets the full requirements of IEC 61672 to Class 2. Before each inclusion the Sound Level Meter was calibrated acoustically using an external reference, i.e the Sound Level Calibrator Model 106, which is placed over the microphone. The calibrator generates a stabilized Sound Pressure Level of 94dB (+- 0.3dB) at a frequency of 1 kHz. Using a Low range (Low = 35dB to 100dB), maximum sound level was measured pressing the MAX HOLD button for at least Âœ second and was ultimately noticed. A level of sound in decibels (L) is defined as ten times the base-10 logarithm of the ratio between two power-related quantities I (i.e cough-volume related sound) and Io (i.e the human hearing threshold) as follows: L = 10 * Log 10 (I/ Io). Thus, an apparent mild increase from 73 to 76 dB in sound level results in multiplying acoustic energy by a factor two
    corecore