13 research outputs found

    Fixation Using Alternative Implants for the Treatment of Hip Fractures

    Get PDF
    Objectives: To conduct a pilot trial for the Fixation using Alternative Implants for the Treatment of Hip Fractures (FAITH-2) protocol to assess feasibility of a definitive trial. Design: Pilot trial. Setting: Twenty-five clinical sites across North America and Australia were initiated, but enrolment occurred in only 15 North American sites. Patients/participants: Ninety-one randomized adults aged 18 to 60 years with a femoral neck fracture requiring surgical fixation. Intervention: Eligible patients were randomized to receive surgical treatment (sliding hip screw or cancellous screws) AND nutritional supplementation (4000 IU of vitamin D or placebo) for 6 months postfracture. Main outcome measurements: Feasibility outcomes included: clinical site initiation, participant enrolment rate, proportion of participants with complete 12-month follow-up, level of data quality, and rate of protocol adherence (number of randomization errors, crossovers between treatment groups, and daily supplementation adherence). Results: Eighty-six of 91 participants randomized into the pilot trial from 15 North American hospitals were deemed eligible. Four of five primary feasibility criteria were not achieved as we were unable to initiate clinical sites outside of North America and Australia due to feasibility constraints, slow participant enrolment (60 participants recruited over 36 mo), low adherence with daily nutritional supplementation at the 6-week (72.1%), 3-month (60.5%), and 6-month (54.7%) follow-up visits, and a high loss to follow-up rate of 22.1% at 12 months. Conclusions: Despite not meeting key feasibility criteria, we increased our knowledge on the logistics and anticipated barriers when conducting vitamin D supplementation trials in this trauma population, which can be used to inform the design and conduct of future trials on this topic

    Fixation Using Alternative Implants for the Treatment of Hip Fractures (FAITH-2): The Clinical Outcomes of a Multicenter 2 × 2 Factorial Randomized Controlled Pilot Trial in Young Femoral Neck Fracture Patients

    Get PDF
    Objective: To assess whether the fixation method and vitamin D supplementation affect the risk of patient-important outcomes within 12 months of injury in nongeriatric femoral neck fracture patients. Design: A pilot factorial randomized controlled trial. Setting: Fifteen North American clinical sites. Participants: Ninety-one adults 18–60 years of age with a femoral neck fracture requiring surgical fixation. Intervention: Participants were randomized to a surgical intervention (sliding hip screw or cancellous screws) and a vitamin D intervention (vitamin D3 4000 IU daily vs. placebo for 6 months). Main Outcome Measurements: The primary clinical outcome was a composite of patient-important complications (reoperation, femoral head osteonecrosis, severe femoral neck malunion, and nonunion). Secondary outcomes included fracture-healing complications and radiographic fracture healing. Results: Eighty-six participants with a mean age of 41 years were included. We found no statistically significant difference in the risk of patient-important outcomes between the surgical treatment arms (hazard ratio 0.90, 95% confidence interval 0.40–2.02, P = 0.80) and vitamin D supplementation treatment arms (hazard ratio 0.96, 95% confidence interval 0.42–2.18, P = 0.92). Conclusions: These pilot trial results continue to describe the results of current fixation implants, inform the challenges of improving outcomes in this fracture population, and may guide future vitamin D trials to improve healing outcomes in young fracture populations. Although the pilot trial was not adequately powered to detect treatment effects, publishing these results may facilitate future meta-analyses on this topic. Level of Evidence: Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence

    Correction to: Cluster identification, selection, and description in Cluster randomized crossover trials: the PREP-IT trials

    Get PDF
    An amendment to this paper has been published and can be accessed via the original article

    Patient and stakeholder engagement learnings: PREP-IT as a case study

    Get PDF

    Factors Associated with Revision Surgery after Internal Fixation of Hip Fractures

    Get PDF
    Background: Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. Methods: We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Results: Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (fo

    A Multicenter Randomized Control Trial Comparing a Novel Intramedullary Device (InterTAN) Versus Conventional Treatment (Sliding Hip Screw) of Geriatric Hip Fractures

    No full text
    Copyright © 2016 Wolters Kluwer Health, Inc. All rights reserved. Objectives: To compare outcomes in elderly patients with intertrochanteric hip fractures treated with either the sliding hip screw (SHS) or InterTAN intramedullary device (IT). Design: Prospective, randomized, multicenter clinical trial. Setting: Five level 1 trauma centers. Patients: Two hundred forty-nine patients 55 years of age or older with AO/OTA 31A1 (43) and OA/OTA 31A2 (206) fractures were prospectively enrolled and followed for 12 months. Intervention: Computer generated randomization to either IT (n = 123) or SHS (n = 126). Main Outcome Measurements: The Functional Independence Measure (FIM) and the Timed Up and Go test (TUG) were used to measure function and motor performance. Secondary outcome measures included femoral shortening, complications, and mortality. Results: Demographics, comorbidities, preinjury FIM scores and TUG scores were similar between groups. Patients (17.2%) who received an IT had limb shortening greater than 2 cm compared with 42.9% who received an SHS (P \u3c 0.001). To determine the importance of preinjury function and fracture stability, we analyzed the subgroup of patients with the ability to walk 150 m independently preinjury and an OA/OTA 31A-2 fracture (n = 70). In this subgroup, patients treated with SHS had greater shortening and demonstrated poorer FIM and TUG scores compared with patients treated with an IT. Conclusions: Overall, most patients with intertrochanteric femur fractures can expect similar functional results whether treated with an intramedullary or extramedullary device. However, active, functional patients have an improved outcome when the InterTAN is used to treat their unstable intertrochanteric fracture. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence

    Lateral Extra-articular Tenodesis Reduces Failure of Hamstring Tendon Autograft Anterior Cruciate Ligament Reconstruction: 2-Year Outcomes From the STABILITY Study Randomized Clinical Trial

    No full text
    © 2020 The Author(s). Background: Persistent anterolateral rotatory laxity after anterior cruciate ligament (ACL) reconstruction (ACLR) has been correlated with poor clinical outcomes and graft failure. Hypothesis: We hypothesized that a single-bundle, hamstring ACLR in combination with a lateral extra-articular tenodesis (LET) would reduce the risk of ACLR failure in young, active individuals. Study Design: Randomized controlled trial; Level of evidence, 1. Methods: This is a multicenter, prospective, randomized clinical trial comparing a single-bundle, hamstring tendon ACLR with or without LET performed using a strip of iliotibial band. Patients 25 years or younger with an ACL-deficient knee were included and also had to meet at least 2 of the following 3 criteria: (1) grade 2 pivot shift or greater, (2) a desire to return to high-risk/pivoting sports, (3) and generalized ligamentous laxity (GLL). The primary outcome was ACLR clinical failure, a composite measure of rotatory laxity or a graft rupture. Secondary outcome measures included the P4 pain scale, Marx Activity Rating Scale, Knee injury Osteoarthritis and Outcome Score (KOOS), International Knee Documentation Committee score, and ACL Quality of Life Questionnaire. Patients were reviewed at 3, 6, 12, and 24 months postoperatively. Results: A total of 618 patients (297 males; 48%) with a mean age of 18.9 years (range, 14-25 years) were randomized. A total of 436 (87.9%) patients presented preoperatively with high-grade rotatory laxity (grade 2 pivot shift or greater), and 215 (42.1%) were diagnosed as having GLL. There were 18 patients lost to follow-up and 11 who withdrew (~5%). In the ACLR group, 120/298 (40%) patients sustained the primary outcome of clinical failure, compared with 72/291 (25%) in the ACLR+LET group (relative risk reduction [RRR], 0.38; 95% CI, 0.21-0.52; P \u3c.0001). A total of 45 patients experienced graft rupture, 34/298 (11%) in the ACLR group compared with 11/291 (4%) in the ACL+LET group (RRR, 0.67; 95% CI, 0.36-0.83; P \u3c.001). The number needed to treat with LET to prevent 1 patient from graft rupture was 14.3 over the first 2 postoperative years. At 3 months, patients in the ACLR group had less pain as measured by the P4 (P =.003) and KOOS (P =.007), with KOOS pain persisting in favor of the ACLR group to 6 months (P =.02). No clinically important differences in patient-reported outcome measures were found between groups at other time points. The level of sports activity was similar between groups at 2 years after surgery, as measured by the Marx Activity Rating Scale (P =.11). Conclusion: The addition of LET to a single-bundle hamstring tendon autograft ACLR in young patients at high risk of failure results in a statistically significant, clinically relevant reduction in graft rupture and persistent rotatory laxity at 2 years after surgery. Registration: NCT02018354 (ClinicalTrials.gov identifier)

    Implementing stakeholder engagement to explore alternative models of consent: An example from the PREP-IT trials

    No full text
    Introduction: Cluster randomized crossover trials are often faced with a dilemma when selecting an optimal model of consent, as the traditional model of obtaining informed consent from participant's before initiating any trial related activities may not be suitable. We describe our experience of engaging patient advisors to identify an optimal model of consent for the PREP-IT trials. This paper also examines surrogate measures of success for the selected model of consent. Methods: The PREP-IT program consists of two multi-center cluster randomized crossover trials that engaged patient advisors to determine an optimal model of consent. Patient advisors and stakeholders met regularly and reached consensus on decisions related to the trial design including the model for consent. Patient advisors provided valuable insight on how key decisions on trial design and conduct would be received by participants and the impact these decisions will have. Results: Patient advisors, together with stakeholders, reviewed the pros and cons and the requirements for the traditional model of consent, deferred consent, and waiver of consent. Collectively, they agreed upon a deferred consent model, in which patients may be approached for consent after their fracture surgery and prior to data collection. The consent rate in PREP-IT is 80.7%, and 0.67% of participants have withdrawn consent for participation. Discussion: Involvement of patient advisors in the development of an optimal model of consent has been successful. Engagement of patient advisors is recommended for other large trials where the traditional model of consent may not be optimal

    Nutzenbewertung von Trainingsinterventionen fĂŒr die Sturzprophylaxe bei Ă€lteren Menschen - eine systematische Übersicht auf der Grundlage systematischer Übersichten

    No full text

    Fixation using alternative implants for the treatment of hip fractures (FAITH): design and rationale for a multi-centre randomized trial comparing sliding hip screws and cancellous screws on revision surgery rates and quality of life in the treatment of femoral neck fractures

    No full text
    corecore