17 research outputs found

    Vegetation maps based on remote sensing are informative predictors of habitat selection of grassland birds across a wetness gradient

    Get PDF
    Vegetation is a major environmental factor influencing habitat selection in bird species. High resolution mapping of vegetation cover is essential to model the distribution of populations and improve the management of breeding habitats. However, the task is challenging for grassland birds because microhabitat variations relevant at the territory scale cannot be measured continuously over large areas to delineate areas of higher suitability. Remote sensing may help to circumvent this problem. We addressed this issue by using two methods. We (i) mapped the continuous Ellenberg index of moisture and (ii) identified 5 vegetation classes distributed accross the wetness gradient. These two methods produced consistent output maps, but they also provided more information about vegetation structure, and possibly trophic resources. In spite of the apprent uniformity of meadows, our data show that birds do not settle randomly along the moisture and vegetation gradients. Overall birds tend to avoid the driest vegetation classes, i.e. the highest grounds. Thus, vegetation maps based on remote sensing could be valuable tools to study habitat selection and niche partition in grassland bird communities. It is also a valuable tool for conservation and habitat management

    Assimilation of phytate-phosphorus by the extracellular phytase activity of tobacco (Nicotiana tabacum) is affected by the availability of soluble phytate

    Get PDF
    Phytate, the major organic phosphorus in soil, is not readily available to plants as a source of phosphorus (P). It is either complexed with cations or adsorbed to various soil components. The present study was carried out to investigate the extracellular phytase activities of tobacco (Nicotiana tabacum variety GeXin No.1) and its ability to assimilate external phytate-P. Whereas phytase activities in roots, shoots and growth media of P i-fed 14-day-old seedlings were only 1.3-4.9% of total acid phosphatase (APase) activities, P starvation triggered an increase in phytase secretion up to 914.9 mU mg -1 protein, equivalent to 18.2% of total APase activities. Much of the extracellular phytase activities were found to be root-associated than root-released. The plants were not able to utilize phytate adsorbed to sand, except when insoluble phytate salts were preformed with Mg 2+ and Ca 2+ ions for supplementation. Tobacco grew better in sand supplemented with Mg-phytate salts (31.9 mg dry weight plant -1; 0.68% w/w P concentration) than that with Ca-phytate salts (9.5 mg plant -1; 0.42%), presumably due to its higher solubility. We conclude that insolubility of soil phytate is the major constrain for its assimilation. Improving solubility of soil phytate, for example, by enhancement of citrate secretion, may be a feasible approach to improve soil phytate assimilation. © Springer 2006.postprin

    Impact of baseline and newly acquired conduction disorders on need for permanent pacemakers with 3 consecutive generations of self-expanding transcatheter aortic heart valves

    Get PDF
    Introductions: We aimed to compare conduction dynamics and need for permanent pacemaker implantation (PPI) after CoreValve, Evolut R and PRO (transcatheter aortic valve replacement (TAVR)). Methods: Patients were stratified based on conduction at baseline; Cohort A had normal conduction, Cohort B had conduction abnormalities including atrioventricular (AV)-block, fascicular block or complete bundle branch block. Three different dynamic QRS-patterns were defined: stable QRS-duration, transient QRS-prolongation and persistent QRS-prolongation. We performed multivariable regression analysis to estimate the effect of the three separate transcatheter heart valves (THV's) on need for PPI at 30 days. Results: TAVR was performed with CoreValve (N = 113), Evolut R (N = 157) or Evolut PRO (N = 92). Conduction dynamics were similar between the different THVs. Overall, Evolut R and PRO showed a tendency towards less PPI compared to CoreValve (17% vs. 19% vs. 27%, P = 0.08), which was driven by a lower PPI rate in Cohort A (6% vs. 11% vs. 25%, P = 0.002). Need for PPI was restricted to patients with persistent QRS-prolongation in Cohort A (26/106) but did not correlate with conduction dynamics in Cohort B. In multivariable logistic regression analysis the use of Evolut R (OR 0.38, 95% CI 0.19–0.78, P = 0.008) and PRO (OR 0.41, 95% CI 0.19–0.91, P-value = 0.028) were independently associated with less need for PPI. Conclusion: The newer generations Evolut R and PRO were associated with less PPI compared to CoreValve. Acquired persistent conduction abnormalities predicted PPI after TAVR only in patients with normal conduction at baseline. Our findings may help identify eligible patients for early discharge after Evolut R/PRO TAVR

    Transcription des noms indigènes sur les cartes d’Afrique du Nord

    No full text
    Maugenest J. Transcription des noms indigènes sur les cartes d’Afrique du Nord. In: Onomastica. Revue Internationale de Toponymie et d'Anthroponymie, 2e année N°2, juin 1948. Deuxième congrès international de toponymie et d'anthroponymie (3e et dernière série) pp. 147-151

    Design and principle of operation of the HeartMate PHP (percutaneous heart pump)

    No full text
    The HeartMate PHP (percutaneous heart pump) is a second-generation transcatheter axial flow circulatory support system. The collapsible catheter pump is inserted through a 14 Fr sheath, deployed across the aortic valve expanding to 24 Fr and able to deliver up to 5 L/min blood flow at minimum haemolytic risk. As such, this device may be a valuable adjunct to percutaneous coronary intervention (PCI) of challenging lesions in high-risk patients or treatment of cardiogenic shock. This technical report discusses: (i) the HeartMate PHP concept, (ii) the implantation technique, (iii) the haemodynamic performance in an in vitro cardiovascular flow testing set-up, and (iv) preliminary clinical experience. An update on the device, produced by St. Jude Medical/Abbott Laboratories, can be found in the Appendix

    Timing and potential mechanisms of new conduction abnormalities during the implantation of the Medtronic CoreValve System in patients with aortic stenosis

    No full text
    Aims New-onset left bundle branch block (LBBB) and complete atrioventricular block (AV3B) frequently occur following transcatheter aortic valve implantation (TAVI). We sought to determine the timing and potential mechanisms of new conduction abnormalities (CAs) during TAVI, using the Medtronic CoreValve System (MCS). Methods and results Sixty-five consecutive patients underwent TAVI with continuous 12-lead ECG analysis. New CAs were defined by the occurrence of LBBB, RBBB, and/or AV3B after the following pre-defined time points: (i) crossing of valve with stiff wire, (ii) positioning of balloon catheter in the aortic annulus, (iii) balloon valvuloplasty, (iv) positioning of MCS in the left ventricular outflow tract (LVOT), (v) expansion of MCS, (vi) removal of all catheters. A new CA occurred during TAVI in 48 patients (74%) and after TAVI in 5 (8%). Of the 48 patients with procedural CAs, a single new CA occurred in 43 patients (90%) and two types of CAs in 5 (10%). A new LBBB was seen in 40 patients (83%), AV3B in 9 (19%), and RBBB in 4 (8%). The new CA first occurred-in descending order of frequency-after balloon valvuloplasty in 22 patients (46%), MCS expansion in 14 (29%), MCS positioning in 6 (12%), positioning of balloon catheter in 3 (6%), wire-crossing of aortic valve in 2 (4%), and after catheter removal in 1 patient (2%). Patients who developed a new CA during balloon valvuloplasty had a significantly higher balloon/annulus ratio than those who did not (1.10 +/- 0.10 vs. 1.03 +/- 0.11, P = 0.030). No such relationship was found with the valve/annulus ratio. Conclusion Transcatheter aortic valve implantation with the MCS was associated with new CAs in 82% of which more than half occurred before the actual valve implantation. It remains to be elucidated by dedicated studies whether new CAs can be reduced by appropriate balloon sizing-a precept that also holds for valve size given the observed directional signal of the valve size/aortic annulus ratio
    corecore