172 research outputs found

    LC–MS–MS Method for the Analysis of New Non-Imidazole Histamine H3 Receptor Antagonist 1-[3-(4-tert-Butylphenoxy)propyl]piperidine in Rat Serum—Application to Pharmacokinetic Studies

    Get PDF
    A sensitive and specific liquid chromatography electrospray ionisation–tandem mass spectrometry method for determination of new non-imidazole histamine H3 receptor antagonist 1-[3-(4-tert-butylphenoxy)propyl]piperidine (DL76) in rat serum has been developed and validated. Chromatography was performed on a XBridge™ C18 analytical column (2.1 × 30 mm, 3.5 µm, Waters, Ireland) with gradient elution using a mobile phase containing acetonitrile and water with an addition of 0.1% of formic acid. Detection was achieved by an Applied Biosystems MDS Sciex (Concord, Ontario, Canada) API 2000 triple quadrupole mass spectrometer. Electrospray ionization (ESI) was used for ion production. The limit of detection in the SRM mode was found to be 0.5 ng mL−1. The limit of quantification was 1 ng mL−1. The precision and accuracy for both intra- and inter-day determination of DL76 ranged from 1.65 to 15.09% and from 88.74 to 113.43%. The results of this analytical method validation allow to carry out pharmacokinetic studies in rats. The method was used for the pilot study of the pharmacokinetic behavior of DL76 in rats after intravenous administration

    New psychoactive substance Α-PVP in a traffic accident case

    Get PDF
    The problems of new psychoactive substances (NPSs), especially related to drivers, constitute an open research area. In this case report, we present a traffic accident case, in which two passengers of five individuals died instantly, while the other three persons survived the accident with minor injuries only. From the blood samples of the driver and the passengers, α-pyrrolidinovalerophenone (α-PVP), an NPS belonging to the category of cathinone derivatives, was disclosed. Therefore, we established a detailed procedure for analysis of α-PVP in blood samples by liquid chromatography–tandem mass spectrometry. After careful validation tests of this method, α-PVP concentration in blood samples from the surviving driver and passengers, and from the two deceased, were measured. The concentrations varied from 20 to 650 ng/mL. Access to detailed information originating from the court files and from explanations provided by the driver and eye witnesses revealed extremely valuable illustrative details addressing the symptoms and pharmacological effects of α-PVP on the human organism, thus contributing to enriching the body of knowledge of α-PVP abuse

    Development of an online SPE–LC–MS-based assay using endogenous substrate for investigation of soluble epoxide hydrolase (sEH) inhibitors

    Get PDF
    Soluble epoxide hydrolase (sEH) is a promising therapeutic target for the treatment of hypertension, pain, and inflammation-related diseases. In order to enable the development of sEH inhibitors (sEHIs), assays are needed for determination of their potency. Therefore, we developed a new method utilizing an epoxide of arachidonic acid (14(15)-EpETrE) as substrate. Incubation samples were directly injected without purification into an online solid phase extraction (SPE) liquid chromatography electrospray ionization tandem mass spectrometry (LC–ESI–MS–MS) setup allowing a total run time of only 108 s for a full gradient separation. Analytes were extracted from the matrix within 30 s by turbulent flow chromatography. Subsequently, a full gradient separation was carried out on a 50X2.1 mm RP-18 column filled with 1.7 μm core–shell particles. The analytes were detected with high sensitivity by ESI–MS–MS in SRM mode. The substrate 14(15)-EpETrE eluted at a stable retention time of 96 ± 1 s and its sEH hydrolysis product 14,15-DiHETrE at 63 ± 1 s with narrow peak width (full width at half maximum height: 1.5 ± 0.1 s). The analytical performance of the method was excellent, with a limit of detection of 2 fmol on column, a linear range of over three orders of magnitude, and a negligible carry-over of 0.1% for 14,15-DiHETrE. The enzyme assay was carried out in a 96-well plate format, and near perfect sigmoidal dose–response curves were obtained for 12 concentrations of each inhibitor in only 22 min, enabling precise determination of IC50 values. In contrast with other approaches, this method enables quantitative evaluation of potent sEHIs with picomolar potencies because only 33 pmol L−1 sEH were used in the reaction vessel. This was demonstrated by ranking ten compounds by their activity; in the fluorescence method all yielded IC50 ≤ 1 nmol L−1. Comparison of 13 inhibitors with IC50 values >1 nmol L−1 showed a good correlation with the fluorescence method (linear correlation coefficient 0.9, slope 0.95, Spearman’s rho 0.9). For individual compounds, however, up to eightfold differences in potencies between this and the fluorescence method were obtained. Therefore, enzyme assays using natural substrate, as described here, are indispensable for reliable determination of structure–activity relationships for sEH inhibition

    Stable isotope dilution assay for the accurate determination of mycotoxins in maize by UHPLC-MS/MS

    Get PDF
    A fast, easy-to-handle and cost-effective analytical method for 11 mycotoxins currently regulated in maize and other cereal-based food products in Europe was developed and validated for maize. The method is based on two extraction steps using different acidified acetonitrile–water mixtures. Separation is achieved using ultrahigh-performance liquid chromatography (UHPLC) by a linear water–methanol gradient. After electrospray ionisation, tandem mass spectrometric detection is performed in dynamic multiple reaction monitoring mode. Since accurate mass spectrometric quantification is hampered by matrix effects, uniformly [13C]-labelled mycotoxins for each of the 11 compounds were added to the sample extracts prior to UHPLC-MS/MS analysis. Method performance parameters were obtained by spiking blank maize samples with mycotoxins before as well as after extraction on six levels in triplicates. The twofold extraction led to total recoveries of the extraction steps between 97% and 111% for all target analytes, including fumonisins. The [13C]-labelled internal standards efficiently compensated all matrix effects in electrospray ionisation, leading to apparent recoveries between 88% and 105% with reasonable additional costs. The relative standard deviations of the whole method were between 4% and 11% for all analytes. The trueness of the method was verified by the measurement of several maize test materials with well-characterized concentrations. In conclusion, the developed method is capable of determining all regulated mycotoxins in maize and presuming similar matrix effects and extraction recovery also in other cereal-based foods

    Simultaneous Quantitation of Amino Acid Mixtures using Clustering Agents

    Get PDF
    A method that uses the abundances of large clusters formed in electrospray ionization to determine the solution-phase molar fractions of amino acids in multi-component mixtures is demonstrated. For solutions containing either four or 10 amino acids, the relative abundances of protonated molecules differed from their solution-phase molar fractions by up to 30-fold and 100-fold, respectively. For the four-component mixtures, the molar fractions determined from the abundances of larger clusters consisting of 19 or more molecules were within 25% of the solution-phase molar fractions, indicating that the abundances and compositions of these clusters reflect the relative concentrations of these amino acids in solution, and that ionization and detection biases are significantly reduced. Lower accuracy was obtained for the 10-component mixtures where values determined from the cluster abundances were typically within a factor of three of their solution molar fractions. The lower accuracy of this method with the more complex mixtures may be due to specific clustering effects owing to the heterogeneity as a result of significantly different physical properties of the components, or it may be the result of lower S/N for the more heterogeneous clusters and not including the low-abundance more highly heterogeneous clusters in this analysis. Although not as accurate as using traditional standards, this clustering method may find applications when suitable standards are not readily available

    Simultaneous measurement of endogenous cortisol, cortisone, dehydroepiandrosterone, and dehydroepiandrosterone sulfate in nails by use of UPLC-MS-MS

    Get PDF
    Steroid hormone concentrations are mostly determined by using different body fluids as matrices and applying immunoassay techniques. However, usability of these approaches may be restricted for several reasons, including ethical barriers to invasive sampling. Therefore, we developed an ultra-performance LC-MS-MS method for high-throughput determination of concentrations of cortisol, cortisone, dehydroepiandrosterone (DHEA), and DHEA sulfate (DHEAS) in small quantities of human nails. The method was validated for linearity, limits of detection and quantification, recovery, intra and interassay precision, accuracy, and matrix effect. Samples from 10 adult women were analyzed to provide proof-of-principle for the method's applicability. Calibration curves were linear (r (2)?14% for all analytes) and accuracy (relative error (%) -8.3% to 12.2% for all analytes). The median (pg mg(-1), range) hormone concentrations were 69.5 (36-158), 65 (32-133), 212 (50-1077), and 246 (115-547) for cortisol, cortisone, DHEA, and DHEAS, respectively. This method enables measurement of cortisol, cortisone, DHEA, and DHEAS in small quantities of human nails, leading to the development of applications in endocrinology and beyond
    • …
    corecore