324 research outputs found

    Snakebite: An Exploratory Cost-Effectiveness Analysis of Adjunct Treatment Strategies.

    Get PDF
    The cost-effectiveness of the standard of care for snakebite treatment, antivenom, and supportive care has been established in various settings. In this study, based on data from South Indian private health-care providers, we address an additional question: "For what cost and effectiveness values would adding adjunct-based treatment strategies to the standard of care for venomous snakebites be cost-effective?" We modeled the cost and performance of potential interventions (e.g., pharmacologic or preventive) used adjunctively with antivenom and supportive care for the treatment of snakebite. Because these potential interventions are theoretical, we used a threshold cost-effectiveness approach to explore this forward-looking concept. We examined economic parameters at which these interventions could be cost-effective or even cost saving. A threshold analysis was used to examine the addition of new interventions to the standard of care. Incremental cost-effectiveness ratios were used to compare treatment strategies. One-way, scenario, and probabilistic sensitivity analyses were conducted to analyze parameter uncertainty and define cost and effectiveness thresholds. Our results suggest that even a 3% reduction in severe cases due to an adjunct strategy is likely to reduce the cost of overall treatment and have the greatest impact on cost-effectiveness. In this model, for example, an investment of 10ofinterventionthatreducestheincidenceofseverecasesby310 of intervention that reduces the incidence of severe cases by 3%, even without changing antivenom usage patterns, creates cost savings of 75 per individual. These findings illustrate the striking degree to which an adjunct intervention could improve patient outcomes and be cost-effective or even cost saving

    Evaluation of Tinnitus in the Emergency Department

    Get PDF

    Potentially Low Cost Solution to Extend Use of Early Generation Computed Tomography

    Get PDF
    In preparing a case report on Brown-SĂ©quard syndrome for publication, we made the incidental finding that the inexpensive, commercially available three-dimensional (3D) rendering software we were using could produce high quality 3D spinal cord reconstructions from any series of two-dimensional (2D) computed tomography (CT) images. This finding raises the possibility that spinal cord imaging capabilities can be expanded where bundled 2D multi-planar reformats and 3D reconstruction software for CT are not available and in situations where magnetic resonance imaging (MRI) is either not available or appropriate (e.g. metallic implants). Given the worldwide burden of trauma and considering the limited availability of MRI and advanced generation CT scanners, we propose an alternative, potentially useful approach to imaging spinal cord that might be useful in areas where technical capabilities and support are limited

    Willingness to participate in a randomized trial comparing catheters to fistulas for vascular access in incident hemodialysis patients: an international survey of nephrologists

    Get PDF
    BACKGROUND: Current guidelines favor fistulas over catheters as vascular access. Yet, the observational literature comparing fistulas to catheters has important limitations and biases that may be difficult to overcome in the absence of randomization. However, it is not clear if physicians would be willing to participate in a clinical trial comparing fistulas to catheters. OBJECTIVES: We also sought to elicit participants' opinions on willingness to participate in a future trial regarding catheters and fistulas. DESIGN: We created a three-part survey consisting of 19 questions. We collected demographic information, respondents' knowledge of the vascular access literature, appropriateness of current guideline recommendations, and their willingness to participate in a future trial. SETTING: Participants were recruited from Canada, Europe, Australia, and New Zealand. PARTICIPANTS: Participants include physicians and trainees who are involved in the care of end-stage renal disease patients requiring vascular access. MEASUREMENTS: Descriptive statistics were used to describe baseline characteristics of respondents according to geographic location. We used logistic regression to model willingness to participate in a future trial. METHODS: We surveyed nephrologists from Canada, Europe, Australia, and New Zealand to assess their willingness to participate in a randomized trial comparing fistulas to catheters in incident hemodialysis patients. RESULTS: Our results show that in Canada, 86 % of respondents were willing to participate in a trial (32 % in all patients; 54 % only in patients at high risk of primary failure). In Europe and Australia/New Zealand, the willingness to participate in a trial that included all patients was lower (28 % in Europe; 25 % in Australia/New Zealand), as was a trial that included patients at high risk of primary failure (38 % in Europe; 39 % in Australia/New Zealand). Nephrologists who have been in practice for a few years, saw a larger volume of patients, or self-identified as experts in vascular access literature were more likely to participate in a trial. LIMITATIONS: Survey distribution was limited to vascular access experts in participating European countries and ultimately led to a discrepancy in numbers of European to non-European respondents overall. Canadian views are likely over-represented in the overall outcomes. CONCLUSIONS: Our survey results suggest that nephrologists believe there is equipoise surrounding the optimal vascular access strategy and that a randomized controlled study should be undertaken, but restricted to those individuals with a high risk of primary fistula failure

    Feasibility of detecting orthopaedic screw overtightening using acoustic emission

    Get PDF
    A preliminary study of acoustic emission during orthopaedic screw fixation was performed using polyurethane foam as the bone-simulating material. Three sets of screws, a dynamic hip screw, a small fragment screw and a large fragment screw, were investigated, monitoring acoustic-emission activity during the screw tightening. In some specimens, screws were deliberately overtightened in order to investigate the feasibility of detecting the stripping torque in advance. One set of data was supported by load cell measurements to directly measure the axial load through the screw. Data showed that acoustic emission can give good indications of impending screw stripping; such indications are not available to the surgeon at the current state of the art using traditional torque measuring devices, and current practice relies on the surgeon’s experience alone. The results suggest that acoustic emission may have the potential to prevent screw overtightening and bone tissue damage, eliminating one of the commonest sources of human error in such scenarios
    • …
    corecore