254 research outputs found

    In silico evaluation of limited sampling strategies for individualized dosing of extended half-life factor IX concentrates in hemophilia B patients

    Get PDF
    PURPOSE: Hemophilia B is a bleeding disorder, caused by a factor IX (FIX) deficiency. Recently, FIX concentrates with extended half-life (EHL) have become available. Prophylactic dosing of EHL-FIX concentrates can be optimized by assessment of individual pharmacokinetic (PK) parameters. To determine these parameters, limited sampling strategies (LSSs) may be applied. The study aims to establish adequate LSSs for estimating individual PK parameters of EHL-FIX concentrates using in silico evaluation. METHODS: Monte Carlo simulations were performed to obtain FIX activity versus time profiles using published population PK models for N9-GP (Refixia), rFIXFc (Alprolix), and rIX-FP (Idelvion). Fourteen LSSs, containing three or four samples taken within 8 days after administration, were formulated. Bayesian analysis was applied to obtain estimates for clearance (CL), half-life (t(1/2)), time to 1% (Time(1%)), and calculated weekly dose (Dose(1%)). Bias and precision of these estimates were assessed to determine which LSS was adequate. RESULTS: For all PK parameters of N9-GP, rFIXFc and rIX-FP bias was generally acceptable (range: −5% to 5%). For N9-GP, precision of all parameters for all LSSs was acceptable (< 25%). For rFIXFc, precision was acceptable for CL and Time(1%), except for t(1/2) (range: 27.1% to 44.7%) and Dose(1%) (range: 12% to 29.4%). For rIX-FP, all LSSs showed acceptable bias and precision, except for Dose(1%) using LSS with the last sample taken on day 3 (LSS 6 and 10). CONCLUSION: Best performing LSSs were LSS with samples taken at days 1, 5, 7, and 8 (N9-GP and rFIXFc) and at days 1, 4, 6, and 8 (rIX-FP), respectively

    Transitions/relaxations in polyester adhesive/PET system

    Get PDF
    The correlations between the transitions and the dielectric relaxation processes of the oriented poly(ethylene terephthalate) (PET) pre-impregnated of the polyester thermoplastic adhesive have been investigated by differential scanning calorimetry (DSC) and dynamic dielectric spectroscopy (DDS). The thermoplastic polyester adhesive and the oriented PET films have been studied as reference samples. This study evidences that the adhesive chain segments is responsible for the physical structure evolution in the PET-oriented film. The transitions and dielectric relaxation modes’ evolutions in the glass transition region appear characteristic of the interphase between adhesive and PET film, which is discussed in terms of molecular mobility. The storage at room temperature of the adhesive tape involves the heterogeneity of the physical structure, characterized by glass transition dissociation. Thus, the correlation between the transitions and the dielectric relaxation processes evidences a segregation of the amorphous phases. Therefore, the physical structure and the properties of the material have been linked to the chemical characteristics

    Dosing of factor VIII concentrate by ideal body weight is more accurate in overweight and obese haemophilia A patients

    Get PDF
    Aims Under- and, especially, overdosing of replacement therapy in haemophilia A patients may be prevented by application of other morphometric variables than body weight (BW) to dose factor VIII (FVIII) concentrates. Therefore, we aimed to investigate which morphometric variables best describe interindividual variability (IIV) of FVIII concentrate pharmacokinetic (PK) parameters. Methods PK profiling was performed by measuring 3 FVIII levels after a standardized dose of 50 IU kg(-1) FVIII concentrate. A population PK model was constructed, in which IIV for clearance (CL) and central volume of distribution (V1) was quantified. Relationships between CL, V1 and 5 morphometric variables (BW, ideal BW [IBW], lean BW, adjusted BW, and body mass index [BMI]) were evaluated in normal weight (BMI 30 kg m(-2)). Results In total, 57 haemophilia A patients (FVIII Conclusion IBW is the most suitable morphometric variable to explain interindividual FVIII PK variability and is more appropriate to dose overweight and obese patients

    Population pharmacokinetics of the von Willebrand factor-factor VIII interaction in patients with von Willebrand disease

    Get PDF
    Recent studies have reported that patients with von Willebrand disease treated perioperatively with a von Willebrand factor (VWF)/factor VIII (FVIII) concentrate with a ratio of 2.4:1 (Humate P/Haemate P) often present with VWF and/or FVIII levels outside of prespecified target levels necessary to prevent bleeding. Pharmacokinetic (PK)-guided dosing may resolve this problem. As clinical guidelines increasingly recommend aiming for certain target levels of both VWF and FVIII, application of an integrated population PK model describing both VWF activity (VWF:Act) and FVIII levels may improve dosing and quality of care. In total, 695 VWF:Act and 894 FVIII level measurements from 118 patients (174 surgeries) who were treated perioperatively with the VWF/FVIII concentrate were used to develop this population PK model using nonlinear mixed-effects modeling. VWF:Act and FVIII levels were analyzed simultaneously using a turnover model. The protective effect of VWF:Act on FVIII clearance was described with an inhibitory maximum effect function. An average perioperative VWF:Act level of 1.23 IU/mL decreased FVIII clearance from 460 mL/h to 264 mL/h, and increased FVIII half-life from 6.6 to 11.4 hours. Clearly, in the presence of VWF, FVIII clearance decreased with a concomitant increase of FVIII half-life, clarifying the higher FVIII levels observed after repetitive dosing with this concentrate. VWF:Act and FVIII levels during perioperative treatment were described adequately by this newly developed integrated population PK model. Clinical application of this model may facilitate more accurate targeting of VWF:Act and FVIII levels during perioperative treatment with this specific VWF/FVIII concentrate (Humate P/Haemate P).Thrombosis and Hemostasi

    Novel geometrical concept of a high-performance brain PET scanner. Principle, design and performance estimates

    Get PDF
    We present the principle, a possible implementation and performance estimates of a novel geometrical concept for a high-resolution positron emission tomograph. The concept, which can be for example implemented in a brain PET device, promises to lead to an essentially parallax-free 3D image reconstruction with excellent spatial resolution and constrast, uniform over the complete field of view. The key components are matrices of long axially oriented scintillator crystals which are read out at both extremities by segmented Hybrid Photon Detectors. We discuss the relevant design considerations for a 3D axial PET camera module, motivate parameter and material choices, and estimate its performance in terms of spatial and energy resolution. We support these estimates by Monte Carlo simulations and in some cases by first experimental results. From the performance of a camera module, we extrapolate to the reconstruction resolution of a 3D axial PET scanner in a semi-analytical way and compare it to an existing state-of-the art brain PET device. We finally describe a dedicated data acquisition system, capable to fully exploit the advantages of the proposed concept. We conclude that the proposed 3D axial concept and the discussed implementation is a competitive approach for high-resolution brain PET. Excellent energy resolution and Compton enhanced sensitivity are expected to lead to high-quality reconstruction and reduced scanning times

    Perioperative pharmacokinetic-guided factor VIII concentrate dosing in haemophilia (OPTI-CLOT trial):an open-label, multicentre, randomised, controlled trial

    Get PDF
    Background Dosing of replacement therapy with factor VIII concentrate in patients with haemophilia A in the perioperative setting is challenging. Underdosing and overdosing of factor VIII concentrate should be avoided to minimise risk of perioperative bleeding and treatment costs. We hypothesised that dosing of factor VIII concentrate on the basis of a patient's pharmacokinetic profile instead of bodyweight, which is standard treatment, would reduce factor VIII consumption and improve the accuracy of attained factor VIII levels. Methods In this open-label, multicentre, randomised, controlled trial (OPTI-CLOT), patients were recruited from nine centres in Rotterdam, Groningen, Utrecht, Nijmegen, The Hague, Leiden, Amsterdam, Eindhoven, and Maastricht in The Netherlands. Eligible patients were aged 12 years or older with severe or moderate haemophilia A (severe haemophilia was defined as factor VIII concentrations of Findings Between May 1, 2014, and March 1, 2020, 98 patients were assessed for eligibility and 66 were enrolled in the trial and randomly assigned to the pharmacokinetic-guided treatment group (34 [52%]) or the standard treatment group (32 [48%]). Median age was 49.1 years (IQR 35.0 to 62.1) and all participants were male. No difference was seen in consumption of factor VIII concentrate during the perioperative period between groups (mean consumption of 365 IU/kg [SD 202] in pharmacokinetic-guided treatment group vs 379 IU/kg [202] in standard treatment group; adjusted difference -6 IU/kg [95% CI -88 to 100]). Postoperative bleeding occurred in six (18%) of 34 patients in the pharmacokinetic-guided treatment group and three (9%) of 32 in the standard treatment group. One grade 4 postoperative bleeding event occurred, which was in one (3%) patient in the standard treatment group. No treatment-related deaths occurred. Interpretation Although perioperative pharmacokinetic-guided dosing is safe, it leads to similar perioperative factor VIII consumption when compared with standard treatment. However, pharmacokinetic-guided dosing showed an improvement in obtaining factor VIII concentrations within the desired perioperative factor VIII range. These findings provide support to further investigation of pharmacokinetic-guided dosing in perioperative haemophilia care. Copyright (C) 2021 Elsevier Ltd. All rights reserved

    Validation of a perioperative population factor VIII pharmacokinetic model with a large cohort of pediatric hemophilia a patients

    Get PDF
    AIMS: Population pharmacokinetic (PK) models are increasingly applied to perform individualized dosing of factor VIII (FVIII) concentrates in haemophilia A patients. To guarantee accurate performance of a population PK model in dose individualization, validation studies are of importance. However, external validation of population PK models requires independent data sets and is, therefore, seldomly performed. Therefore, this study aimed to validate a previously published population PK model for FVIII concentrates administrated perioperatively. METHODS: A previously published population PK model for FVIII concentrate during surgery was validated using independent data from 87 children with severe haemophilia A with a median (range) age of 2.6 years (0.03–15.2) and body weight of 14 kg (4–57). First, the predictive performance of the previous model was evaluated with MAP Bayesian analysis using NONMEM v7.4. Subsequently, the model parameters were (re)estimated using a combined dataset consisting of the previous modelling data and the data available for the external validation. RESULTS: The previous model underpredicted the measured FVIII levels with a median of 0.17 IU mL(−1). Combining the new, independent and original data, a dataset comprising 206 patients with a mean age of 7.8 years (0.03–77.6) and body weight of 30 kg (4–111) was obtained. Population PK modelling provided estimates for CL, V1, V2, and Q: 171 mL h(−1) 68 kg(−1), 2930 mL 68 kg(−1), 1810 mL 68 kg(−1), and 172 mL h(−1) 68 kg(−1), respectively. This model adequately described all collected FVIII levels, with a slight median overprediction of 0.02 IU mL(−1). CONCLUSIONS: This study emphasizes the importance of external validation of population PK models using real‐life data

    von Willebrand Factor and Factor VIII Clearance in Perioperative Hemophilia A Patients

    Get PDF
    Background von Willebrand factor (VWF) is crucial for optimal dosing of factor VIII (FVIII) concentrate in hemophilia A patients as it protects FVIII from premature clearance. To date, it is unknown how VWF behaves and what its impact is on FVIII clearance in the perioperative setting. Aim To investigate VWF kinetics (VWF antigen [VWF:Ag]), VWF glycoprotein Ib binding (VWF:GPIbM), and VWF propeptide (VWFpp) in severe and moderate perioperative hemophilia A patients included in the randomized controlled perioperative OPTI-CLOT trial. Methods Linear mixed effects modeling was applied to analyze VWF kinetics. One-way and two-way analyses of variance were used to investigate perioperative VWFpp/VWF:Ag ratios and associations with surgical bleeding. Results Fifty-nine patients with median age of 48.8 years (interquartile range: 34.8-60.0) were included. VWF:Ag and VWF:GPIbM increased significantly postoperatively. Blood type non-O or medium risk surgery were associated with higher VWF:Ag and VWF:GPIbM levels compared with blood type O and low risk surgery. VWFpp/VWF:Ag was significantly higher immediately after surgery than 32 to 57 hours after surgery (p < 0.001). Lowest VWF:Ag quartile (0.43-0.92 IU/mL) was associated with an increase of FVIII concentrate clearance of 26 mL/h (95% confidence interval: 2-50 mL/h) compared with highest VWF antigen quartile (1.70-3.84 IU/mL). VWF levels were not associated with perioperative bleeding F (4,227) = 0.54, p = 0.710. Conclusion VWF:Ag and VWF:GPIbM levels increase postoperatively, most significantly in patients with blood type non-O or medium risk surgery. Lower VWF antigen levels did not lead to clinically relevant higher FVIII clearance. VWF:Ag or VWF:GPIbM levels were not associated with perioperative hemorrhage

    Peri-operative desmopressin combined with pharmacokinetic-guided factor VIII concentrate in non-severe haemophilia A patients

    Get PDF
    Introduction: Non-severe haemophilia A patient can be treated with desmopressin or factor VIII (FVIII) concentrate. Combining both may reduce factor consumption, but its feasibility and safety has never been investigated. Aim: We assessed the feasibility and safety of combination treatment in nonsevere haemophilia A patients. Methods: Non-severe, desmopressin responsive, haemophilia A patients were included in one of two studies investigating peri-operative combination treatment. In the single-arm DAVID study intravenous desmopressin (0.3 μg/kg) once-a-day was, after sampling, immediately followed by PK-guided FVIII concentrate, for maximally three consecutive days. The Little DAVID study was a randomized trial in patients undergoing a minor medical procedure, whom received either PK-guided combination treatment (intervention arm) or PK-guided FVIII concentrate only (standard arm) up to 2 days. Dose predictions were considered accurate if the absolute difference between predicted and measured FVIII:C was ≤0.2 IU/mL. Results: In total 32 patients (33 procedures) were included. In the DAVID study (n = 21), of the FVIII:C trough levels 73.7% (14/19) were predicted accurately on day 1 (D1), 76.5% (13/17) on D2. On D0, 61.9% (13/21) of peak FVIII:C levels predictions were accurate. In the Little DAVID study (n = 12), on D0 83.3% (5/6) FVIII:C peak levels for both study arms were predicted accurately. Combination treatment reduced preoperative FVIII concentrate use by 47% versus FVIII monotherapy. Desmopressin side effects were mild and transient. Two bleeds occurred, both despite FVIII:C &gt; 1.00 IU/mL. Conclusion: Peri-operative combination treatment with desmopressin and PK-guided FVIII concentrate dosing in nonsevere haemophilia A is feasible, safe and reduces FVIII consumption.</p
    corecore