3 research outputs found

    Choque extraarticular de cadera secundario a consolidación viciosa tras fractura-avulsión de la espina ilíaca antero inferior : a propósito de un caso

    Get PDF
    The anterior inferior iliac spine (AIIS) avulsion fractures are uncommon, caused by a sudden contraction of the rectus femoris muscle with hyperextension of the hip and knee flexion. We present the clinical case of a 32-year-old mansuffering from pain in his right hip for several years with a history of a AIIS avulsion fracture in his childhood. He presented pain with flexion and internal rotation of the right hip. Physical examination and imaging tests revealed an extra-articular hip impingement secondary to a malunited fracture of AIIS. The patient underwent surgery performing AIIS osteoplasty and excision of the ossification by an anterior mini-open approach. After surgery he was able to re-join sports activity. Malunited fracture of AIIS can cause an extra-articular hip impingement in young sports patients. The treatment by surgical excision of the hypertrophic spine through an anterior mini-open approach allows the correction of the deformity and an early reincorporation to sports activities

    Reliability of a novel electro-medical device for wheal size measurement in allergy skin testing: An exploratory clinical trial

    Get PDF
    Skin prick testing (SPT) is the cornerstone of IgE-mediated allergy diagnosis,1 due to its high sensitivity and specificity.2 However, a uniform method for wheal measurement does not exist. Ansotegui et al.2 recommends to measure wheals in millimeters with a ruler, in many centers they are outlined with a pen and transfer by tape to a paper and then measured. Subsequently, the specialist is able to manually measure the maximum (MD) and orthogonal diameter (OD) of the wheal. This procedure is time consuming and makes repro-ducible measurements difficult.2,3 Knowing the wheal's area could help make a more accurate diagnosis.4 Over the last 30 years, many attempts have been made to develop a device to measure the size of SPT.3 Nexkin DSPT® (Figure S1A,B) is a novel mechatronic system based on 3D laser technology, that automatically locates allergen's wheal and measures its size (MD, OD and area in square millimeters) (Figure S1C)

    Reliability of a novel electro-medical device for wheal size measurement in allergy skin testing: An exploratory clinical trial

    No full text
    Skin prick testing (SPT) is the cornerstone of IgE-mediated allergy diagnosis,1 due to its high sensitivity and specificity.2 However, a uniform method for wheal measurement does not exist. Ansotegui et al.2 recommends to measure wheals in millimeters with a ruler, in many centers they are outlined with a pen and transfer by tape to a paper and then measured. Subsequently, the specialist is able to manually measure the maximum (MD) and orthogonal diameter (OD) of the wheal. This procedure is time consuming and makes repro-ducible measurements difficult.2,3 Knowing the wheal's area could help make a more accurate diagnosis.4 Over the last 30 years, many attempts have been made to develop a device to measure the size of SPT.3 Nexkin DSPT® (Figure S1A,B) is a novel mechatronic system based on 3D laser technology, that automatically locates allergen's wheal and measures its size (MD, OD and area in square millimeters) (Figure S1C)
    corecore