28 research outputs found

    Simple graphene chemiresistors as pH sensors: fabrication and characterization

    Full text link
    We report the fabrication and characterization of a simple gate-free graphene device as a pH sensor. The graphene sheets are made by mechanical exfoliation. Platinum contact electrodes are fabricated with a mask-free process using focused ion beam, and then expanded by silver paint. Annealing is used to improve the electrical contact. The experiment on the fabricated graphene device shows that the resistance of the device decreases linearly with increasing pH values (in the range of 4-10)in the surrounding liquid environment. The resolution achieved in our experiments is approximately 0.3 pH in alkali environment. The sensitivity of the device is calculated as approximately 2 k\Omega /pH. The simple configuration, miniaturized size and the integration ability make graphene-based sensors promising candidates for future micro/nano applications

    Interplay between estrogen receptor and AKT in estradiol-induced alternative splicing.

    Get PDF
    BACKGROUND: Alternative splicing is critical for generating complex proteomes in response to extracellular signals. Nuclear receptors including estrogen receptor alpha (ERα) and their ligands promote alternative splicing. The endogenous targets of ERα:estradiol (E2)-mediated alternative splicing and the influence of extracellular kinases that phosphorylate ERα on E2-induced splicing are unknown. METHODS: MCF-7 and its anti-estrogen derivatives were used for the majority of the assays. CD44 mini gene was used to measure the effect of E2 and AKT on alternative splicing. ExonHit array analysis was performed to identify E2 and AKT-regulated endogenous alternatively spliced apoptosis-related genes. Quantitative reverse transcription polymerase chain reaction was performed to verify alternative splicing. ERα binding to alternatively spliced genes was verified by chromatin immunoprecipitation assay. Bromodeoxyuridine incorporation-ELISA and Annexin V labeling assays were done to measure cell proliferation and apoptosis, respectively. RESULTS: We identified the targets of E2-induced alternative splicing and deconstructed some of the mechanisms surrounding E2-induced splicing by combining splice array with ERα cistrome and gene expression array. E2-induced alternatively spliced genes fall into at least two subgroups: coupled to E2-regulated transcription and ERα binding to the gene without an effect on rate of transcription. Further, AKT, which phosphorylates both ERα and splicing factors, influenced ERα:E2 dependent splicing in a gene-specific manner. Genes that are alternatively spliced include FAS/CD95, FGFR2, and AXIN-1. E2 increased the expression of FGFR2 C1 isoform but reduced C3 isoform at mRNA level. E2-induced alternative splicing of FAS and FGFR2 in MCF-7 cells correlated with resistance to FAS activation-induced apoptosis and response to keratinocyte growth factor (KGF), respectively. Resistance of MCF-7 breast cancer cells to the anti-estrogen tamoxifen was associated with ERα-dependent overexpression of FGFR2, whereas resistance to fulvestrant was associated with ERα-dependent isoform switching, which correlated with altered response to KGF. CONCLUSION: E2 may partly alter cellular proteome through alternative splicing uncoupled to its effects on transcription initiation and aberration in E2-induced alternative splicing events may influence response to anti-estrogens.RIGHTS : This article is licensed under the BioMed Central licence at http://www.biomedcentral.com/about/license which is similar to the 'Creative Commons Attribution Licence'. In brief you may : copy, distribute, and display the work; make derivative works; or make commercial use of the work - under the following conditions: the original author must be given credit; for any reuse or distribution, it must be made clear to others what the license terms of this work are

    Electron transfer and decay processes of highly charged iodine ions

    No full text
    In the present experimental work we have investigated multi-electron transfer processes in Iq+ (q = 10, 15, 20 and 25) + Ne, Ar, Kr and Xe collisions at 1.5q keV energy. Using the coincidence technique between charge-selected projectile and recoil ions, the branching ratios between Auger and radiative decay channels have been measured in decay processes of multiply excited states formed by multi-electron transfer collisions. By combining these ratios with the measured absolute cross sections for total and single electron transfer processes, the partial cross sections for various charge changing processes have been determined. It has been shown that, in all the multi-electron transfer processes investigated, the Auger decays are far dominant over the radiative decay processes and the branching ratios are clearly characterized by the average principal quantum number <n> of the initial excited states of projectile ions, estimated from the extended classical-over-barrier-model (ECBM). We could express the branching ratios in high Rydberg states formed in multi-electron transfer processes by using the decay probability of one Auger electron emission

    Supplementary Material for: Balloon Dilatation for Bronchoscope Delivery (BDBD) in a Swine Model: A Novel Technique for Ultra-Peripheral Lung Field Access and Accurate Biopsy

    No full text
    Introduction: In transbronchial biopsy of peripheral pulmonary lesions, the bronchoscope can reach only a limited depth due to the progressive narrowing of bronchi, which may reduce the diagnostic rate. This study examined the balloon dilatation for bronchoscope delivery (BDBD) technique, employing a novel balloon device to enhance bronchoscopy into the peripheral lung areas. Methods: Anaesthetised swine served as our primary model. Using computed tomography (CT) scans, we positioned virtual targets characterised by a positive bronchus sign and a diameter of 20 mm beneath the pleura. The bronchoscope was navigated along the pathways determined from the CT images. We performed balloon dilatation when bronchial narrowing obstructed progress to assess whether balloon dilatation would enable the bronchoscope to enter further into the periphery. Results: We established 21 virtual targets on the CT scans. An average of 12.1 branches were identified along the pathways on the CT scans; however, bronchoscopy without BDBD only allowed access to an average of 6.7 branches. Based on 72 balloon dilatations with 3.0-mm or 4.0-mm ultra-thin bronchoscopes, there was an average increased access of 3.43 and 5.14 branches per route, respectively, with no significant BDBD complications. The bronchoscope was able to reach the planned location along all pathways, and the mean final bronchoscopic endpoints were at an average distance of 14.7 mm from the pleura. Post-procedure CT confirmed biopsy accuracy. Conclusion: The BDBD technique can enhance access of a flexible bronchoscope into the peripheral lung fields, which could potentially allow more accurate transbronchial interventions for peripheral targets
    corecore