245 research outputs found

    Aflatoxins absorption in the gastro-intestinal tract and in the vaginal mucosa in lactating dairy cows

    Get PDF
    The objective of the experiment was to monitor plasma levels of aflatoxin B1 (AFB1), B2 (AFB2), G1 (AFG1), G2 (AFG2) and M1 (AFM1) in lactating dairy cows fed a single oral bolus with aflatoxin naturally contaminated corn meal (Trial 1). The possible aflatoxins (AFs) absorption through mucous membranes was also investigated using the vaginal mucosa (Trial 2). In trial 1, seven lactating Holstein dairy cows were given a single oral bolus of a naturally contaminated corn meal assuring an intake of 4.89 mg AFB1, 1.01 mg AFB2, 10.63 mg AFG1 and 0.89 mg AFG2. Blood samples were collected at 0 and 5, 10, 15, 20, 25, 30 minutes after treatment. In trial 2 an aflatoxin dosage similar to that of trial 1 was provided through vaginal implant to eight lactating Holstein dairy cows. Blood samples were collected at 0 and 15, 30, 60, 180, 360 minutes after treatment. Individual milk samples of six milkings, one before and five after treatment, were also collected. Plasma and milk samples were analysed by HPLC for AFB1, AFB2, AFG1, AFG2 and AFM1 contents. In trial 1 AFB1 in plasma peaked (33.6 ng/L) as soon as 20 minutes after treatment. The plasma AFM1 was already detectable at 5 minutes (10.4 ng/L) and peaked at 25 minutes (136.3 ng/L). In trial 2 only AFB1 and AFM1 were detectable in plasma, starting from the first sampling time (15 minutes), with values of 10.7 and 0.5 ng/L, respectively. The AFB1 peaked at 30 minutes (23.9 ng/L). The AFB1 excreted in milk as AFM1 had the highest concentration (203.0 ng/L) in the first milking after treatment and decreased close to the starting values after 36 hours from treatment. The prompt appearance of studied aflatoxins, and their metabolites, in plasma suggests absorption might also take place in mouth or oesophageal mucous membranes, before the rumen compartment. Results support the hypothesis that the cytochrome P450 oxidative system, which is present in these tissues and in leukocytes, could be involved in the conversion of the AFB1 in AFM1. The absorption of AFB1 through the vaginal mucosa confirms the passive diffusion as a probable mechanism for AFB1 absorption

    Y-System and Deformed Thermodynamic Bethe Ansatz

    Full text link
    We introduce a new tool, the Deformed TBA (Deformed Thermodynamic Bethe Ansatz), to analyze the monodromy problem of the cubic oscillator. The Deformed TBA is a system of five coupled nonlinear integral equations, which in a particular case reduces to the Zamolodchikov TBA equation for the 3-state Potts model. Our method generalizes the Dorey-Tateo analysis of the (monomial) cubic oscillator. We introduce a Y-system corresponding to the Deformed TBA and give it an elegant geometric interpretation.Comment: 12 pages. Minor corrections in Section

    In situ and in vitro nutritional evaluation of rumen-protected lipids

    Get PDF
    Rumen-protected lipids are a class of products which is increasingly used in ruminant nutrition even if the results are not homogeneous. The different results may be due to different analytical or technological characteristics. Aim of this work was therefore to compare the in situ rumen behaviour of different soaps as well as their in vitro intestinal digestibility

    In vivorelease of aflatoxin B1 bound to different sequestering agents in dairy cows

    Get PDF
    Nine lactating dairy cows, producing 31.08±5.00 kg of milk/cow/day and fed with a Total Mixed Ration (TMR) with an intake of 22.3±0.8 Kg s.s./cow, were used to investigate the resistance of the AFs-SA complex in the rumen and in the gastro-intestinal tract. Two commercial sequestering agents Atox® and Mycosorb® were used. The AFB1 was also mixed to a rumen fluid (R-SA). AFB1 sequestered by Atox®, Mycosorb® and by R-SA were then fed to cows before the morning meal. Milk samples were collected for 6 consecutive milkings and analyzed for AFM1 content. The in vitro binding capacity of the two SA were 94.2% for Atox®, 84.3% for Mycosorb® and 71.86% for the R-SA. Both Atox® and Mycosorb® released some of the sequestered AFB1 determining an increase of the AFM1 in milk as soon as in the 1st milking from oral drenching (4.23±7.33; 23.60±8.23 and 46.06±39.84 ppt for Atox®, Mycosorb® and R-SA respectively). The AFM1 (ng/cow) in milk at the 4th milking was lower (66.04, 661.77 and 1613.04; P<0.05) in Atox® and Mycosorb® than R-SA, respectively. The percentage release of bound AFB1 were 1.63% for Atox®, 20.27% for Mycosorb® and 50.48% for R-SA

    Mucosal absorption of aflatoxin B1 in lactating dairy cows

    Get PDF
    The objective of this experiment was to monitor plasma levels of aflatoxin B1 (AFB1) aflatoxin B2 (AFB2), aflatoxin G1 (AFG1), aflatoxin G2 (AFG2) and aflatoxin M1 (AFM1) in lactating dairy cows fed afltaoxin contaminated corn. Seven lactating Holstein cows were given a bolus of a naturally contaminated corn meal assuring an intake of 4.9mg AFB1, 1.01 mg AFB2, 10.63 mg AFG1 and 0.89 mg AFG2. Vitamin A, at 1,000,000 IU, was also added as a biomarker of intestinal absorption. Blood samples were collected at 0, 15, 30, 60, 120, 180, 270 and 360 min after bolus. Plasma was analyzed by HPLC for AFB1, AFB2, AFG1, AFG2 and AFM1 concentrations. Within the considered time points, the peak plasma AFB1 concentration was obtained as soon as 15 minutes from drenching. The plasma AFM1 concentration was considerable as early as the first collection (15 minutes) and peaked at 270 minutes indicating both a rapid absorption of AFB1 through the rumen wall and metabolization into AFM1 in liver. The plasma palmitate level suggests the intestinal contribution to the aflatoxin plasma level after 120 min

    The INRiM thermo-hydraulic mock-up for thermal energy measurement devices: Design, construction and metrological characterization

    Get PDF
    At the National Institute of Metrological Research (INRiM), the first European thermo-hydraulic simulator (mock-up) for testing both traditional and innovative thermal energy measurement devices and heat cost allocators has been recently built up, in the context of the EU Seventh Framework Programme FP7-SME-2012. The INRiM mock-up is an automatically reconfigurable thermo-hydraulic circuit equipped with a sufficient number of sensors aimed at measuring all the physical quantities involved in direct heat metering. It allows simulating typical central heating systems with several types of water radiators as heat exchangers and characterized by different distribution circuit topologies. The paper describes the INRiM thermo-hydraulic mock-up, highlighting its design features and metrological capabilities and discussing the first measurement results

    Effect of the presence of two commercial adsorbents in animal feed on Aflatoxin B1 determination by ELISA kit test.

    Get PDF
    A rapid AFB1 detection method by ELISA kit test was used on feedstuff samples, and compared to an HPLC method, to verify if the presence of clay-adsorbent (SA) could cause erroneous quantification of the toxin. Samples were obtained using two AFB1-contaminated feedstuffs (7.92 and 17.58 µg/kg for low and high contaminated feeds; LC and HC respectively), added either one of two commercial SAs (Atox® and Myco AD) and three different inclusion doses (0, 10 and 20 g/kg, respectively for CTR, 1% and 2% doses). The HPLC and ELISA data were compared in CTR samples with a paired t-test. The AFB1 recoveries, performed with ELISA, were analysed as a completely randomized design using a 2×2×3 factorial arrangement. The ELISA method tended to underestimate the AFB1 concentrations with respect to the HPLC method, both in HC (P=0.050) and in LC (P<0.001) feedstuffs. A more drastic reduction (P<0.001) was observed when SAs were included in the two feedstuffs. In particular, Atox® determined an AFB1 recovery of 15,5% in HC and 7,6% in LC (1% dose) and of 11,1% in HC and 8,4% in LC (2% dose). Less severe penalisation were observed when Myco AD was added to feeds

    A novel measurement method for accurate heat accounting in historical buildings

    Get PDF
    Nowadays, two different heat accounting methods are available: the direct method, based on heat meters, and the indirect one, based on heat cost allocators. Unfortunately, in existing buildings, due to the plant configuration, heat meters are often technically unfeasible or not cost efficient, whereas heat cost allocators can be easily installed in almost all conditions. At the same time, the indirect method relies on a high number of interconnected devices with installation and operative conditions often variable within the same building and influencing the on-field metrological performances. In this paper, the authors propose a novel "hybrid" method for accurate heat accounting combining the advantages of indirect method with the higher accuracy typical of direct methods. The proposed method has been experimented at INRIM, the primary metrology institute in Italy, assessing the on-field performance in a virtual eight-apartments building. The experimental results show that the proposed method always presents improved accuracy. (C) 2020 Elsevier Ltd. All rights reserved

    Along-the-net reconstruction of hydropower potential with consideration of anthropic alterations

    Get PDF
    Even in regions with mature hydropower development, requirements for stable renewable power sources suggest revision of plans of exploitation of water resources, while taking care of the environmental regulations. Mean Annual Flow (MAF) is a key parameter when trying to represent water availability for hydropower purposes. MAF is usually determined in ungauged basins by means of regional statistical analysis. For this study a regional estimation method consistent along-the-river network has been developed for MAF estimation; the method uses a multi-regressive approach based on geomorphoclimatic descriptors, and it is applied on 100 gauged basins located in NW Italy. The method has been designed to keep the estimates of mean annual flow congruent at the confluences, by considering only raster-summable explanatory variables. Also, the influence of human alterations in the regional analysis of MAF has been studied: impact due to the presence of existing hydropower plants has been taken into account, restoring the "natural" value of runoff through analytical corrections. To exemplify the representation of the assessment of residual hydropower potential, the model has been applied extensively to two specific mountain watersheds by mapping the estimated mean flow for the basins draining into each pixel of a the DEM-derived river network. Spatial algorithms were developed using the OpenSource Software GRASS GIS and PostgreSQL/PostGIS. Spatial representation of the hydropower potential was obtained using different mean flow vs hydraulic-head relations for each pixel. Final potential indices have been represented and mapped through the Google Earth platform, providing a complete and interactive picture of the available potential, useful for planning and regulation purpose
    • …
    corecore