9 research outputs found

    Analysis of aortic valve commissural fusion after support with continuous-flow left ventricular assist device

    No full text
    OBJECTIVES: Continuous-flow left ventricular assist devices (cf-LVADs) may induce commissural fusion of the aortic valve leaflets. Factors associated with this occurrence of commissural fusion are unknown. The aim of this study was to examine histological characteristics of cf-LVAD-induced commissural fusion in relation to clinical variables. METHODS: Gross and histopathological examinations were performed on 19 hearts from patients supported by either HeartMate II (n = 17) or HeartWare (n = 2) cf-LVADs and related to clinical characteristics (14 heart transplantation, 5 autopsy). RESULTS: Eleven of the 19 (58%) aortic valves showed fusion of single or multiple commissures (total fusion length 11 mm [4–20] (median [interquartile range]) per valve), some leading to noticeable nodular displacements or considerable lumen diameter narrowing. Multiple fenestrations were observed in one valve. Histopathological examination confirmed commissural fusion, with varying changes in valve layer structure without evidence of inflammatory infiltration at the site of fusion. Commissural fusion was associated with continuous aortic valve closure during cf-LVAD support (P = 0.03). LVAD-induced aortic valve insufficiency developed in all patients with commissural fusion and in 67% of patients without fusion. Age, duration of cf-LVAD support and aetiology of heart failure (ischaemic vs dilated cardiomyopathy) were not associated with the degree of fusion. CONCLUSIONS: Aortic valve commissural fusion after support with cf-LVADs is a non-inflammatory process leading to changes in valve layer structure that can be observed in >50% of cf-LVAD patients. This is the first study showing that patients receiving full cf-LVAD support without opening of the valve have a significantly higher risk of developing commissural fusion than patients on partial support

    Noninvasive Blood Pressure Measurement by the Nexfin Monitor During Reduced Arterial Pulsatility: A Feasibility Study

    No full text
    Noninvasive blood pressure measurements are difficult when arterial pulsations are reduced, as in patients supported by continuous flow left ventricular assist devices (cf-LVAD). We evaluated the feasibility of measuring noninvasive arterial blood pressure with the Nexfin monitor during conditions of reduced arterial pulsatility. During cardiopulmonary bypass (CPB) in which a roller pump based or a centrifugal pump based heart-lung machine generated arterial blood pressure with low pulsatility, noninvasive arterial pressures (NAP) measured by the Nexfin Monitor were recorded and compared with invasively measured radial artery pressures (IAP). We also evaluated NAP in 10 patients with a cf-LVAD during a pump speed change procedure (PSCP). During CPB in 18 patients, the NAP-IAP average difference was -1.3 +/- 6.5 mm Hg. The amplitude of pressure oscillations were 4.3 +/- 3.8 mm Hg measured by IAP. Furthermore, in the cf-LVAD patients, increase in pump speed settings led to an increase in diastolic and mean arterial pressures (MAP) while the NAP acquired a sinusoidal shape as the aortic valve become permanently closed. In conclusion, NAP was similar to IAP under conditions of reduced arterial pulsatility. The device also measured the blood pressure waveform noninvasively in patients supported by a cf-LVAD. ASAIO Journal 2010; 56:221-22

    Pump Flow Estimation From Pressure Head and Power Uptake for the HeartAssist5, HeartMate II, and HeartWare VADs

    No full text
    The use of long-term mechanical circulatory support (MCS) for heart failure by means of implanted continuous-flow left ventricular assist devices (cf-LVADs) will increase, either to enable recovery or to provide a destination therapy. The effectiveness and user-friendliness of MCS will depend on the development of near-physiologic control strategies for which accurate estimation of pump flow is essential. To provide means for the assessment of pump flow, this study presents pump models, estimating pump flow (Q(lvad)) from pump speed (n) and pressure difference across the LVAD (Delta p(lvad)) or power uptake (P). The models are evaluated for the axial-flow LVADs HeartAssist5 (HA5) and HeartMate II (HMII), and for a centrifugal pump, the HeartWare (HW). For all three pumps, models estimating Q(lvad) from Delta p(lvad) only is capable of describing pump behavior under static conditions. For the axial pumps, flow estimation from power uptake alone was not accurate. When assuming an increase in pump flow with increasing power uptake, low pump flows are overestimated in these pumps. Only for the HW, pump flow increased linearly with power uptake, resulting in a power-based pump model that estimates static pump flow accurately. The addition of pressure head measurements improved accuracy in the axial cf-LVAD estimation model

    Pump Flow Estimation From Pressure Head and Power Uptake for the HeartAssist5, HeartMate II, and HeartWare VADs

    No full text
    The use of long-term mechanical circulatory support (MCS) for heart failure by means of implanted continuous-flow left ventricular assist devices (cf-LVADs) will increase, either to enable recovery or to provide a destination therapy. The effectiveness and user-friendliness of MCS will depend on the development of near-physiologic control strategies for which accurate estimation of pump flow is essential. To provide means for the assessment of pump flow, this study presents pump models, estimating pump flow (Q(lvad)) from pump speed (n) and pressure difference across the LVAD (?p(lvad)) or power uptake (P). The models are evaluated for the axial-flow LVADs HeartAssist5 (HA5) and HeartMate II (HMII), and for a centrifugal pump, the HeartWare (HW). For all three pumps, models estimating Q(lvad) from ?p(lvad) only is capable of describing pump behavior under static conditions. For the axial pumps, flow estimation from power uptake alone was not accurate. When assuming an increase in pump flow with increasing power uptake, low pump flows are overestimated in these pumps. Only for the HW, pump flow increased linearly with power uptake, resulting in a power-based pump model that estimates static pump flow accurately. The addition of pressure head measurements improved accuracy in the axial cf-LVAD estimation models

    Noninvasive arterial blood pressure waveforms in patients with continuous-flow left ventricular assist devices

    No full text
    Arterial blood pressure and echocardiography may provide useful physiological information regarding cardiac support in patients with continuous-flow left ventricular assist devices (cf-LVADs). We investigated the accuracy and characteristics of noninvasive blood pressure during cf-LVAD support. Noninvasive arterial pressure waveforms were recorded with Nexfin (BMEYE, Amsterdam, The Netherlands). First, these measurements were validated simultaneously with invasive arterial pressures in 29 intensive care unit patients. Next, the association between blood pressure responses and measures derived by echocardiography, including left ventricular end-diastolic dimensions (LVEDDs), left ventricular end-systolic dimensions (LVESDs), and left ventricular shortening fraction (LVSF) were determined during pump speed change procedures in 30 outpatients. Noninvasive arterial blood pressure waveforms by the Nexfin monitor slightly underestimated invasive measures during cf-LVAD support. Differences between noninvasive and invasive measures (mean ± SD) of systolic, diastolic, mean, and pulse pressures were -7.6 ± 5.8, -7.0 ± 5.2, -6.9 ± 5.1, and -0.6 ± 4.5 mm Hg, respectively (all <10%). These blood pressure responses did not correlate with LVEDD, LVESD, or LVSF, while LVSF correlated weakly with both pulse pressure (r = 0.24; p = 0.005) and (dP(art)/dt)max (r = 0.25; p = 0.004). The dicrotic notch in the pressure waveform was a better predictor of aortic valve opening (area under the curve [AUC] = 0.87) than pulse pressure (AUC = 0.64) and (dP(art)/dt)max (AUC = 0.61). Patients with partial support rather than full support at 9,000 rpm had a significant change in systolic pressure, pulse pressure, and (dP(art)/dt)max during ramp studies, while echocardiographic measures did not change. Blood pressure measurements by Nexfin were reliable and may thereby act as a compliment to the assessment of the cf-LVAD patien

    Noninvasive continuous arterial blood pressure monitoring with Nexfin®

    No full text
    BACKGROUND: If invasive measurement of arterial blood pressure is not warranted, finger cuff technology can provide continuous and noninvasive monitoring. Finger and radial artery pressures differ; Nexfin® (BMEYE, Amsterdam, The Netherlands) measures finger arterial pressure and uses physiologic reconstruction methodologies to obtain values comparable to invasive pressures. METHODS: Intra-arterial pressure (IAP) and noninvasive Nexfin arterial pressure (NAP) were measured in cardiothoracic surgery patients, because invasive pressures are available. NAP-IAP differences were analyzed during 30 min. Tracking was quantified by within-subject precision (SD of individual NAP-IAP differences) and correlation coefficients. The ranges of pressure change were quantified by within-subject variability (SD of individual averages of NAP and IAP). Accuracy and precision were expressed as group average ± SD of the differences and considered acceptable when smaller than 5 ± 8 mmHg, the Association for the Advancement of Medical Instrumentation criteria. RESULTS: NAP and IAP were obtained in 50 (34-83 yr, 40 men) patients. For systolic, diastolic, mean arterial, and pulse pressure, median (25-75 percentiles) correlation coefficients were 0.96 (0.91-0.98), 0.93 (0.87-0.96), 0.96 (0.90-0.97), and 0.94 (0.85-0.98), respectively. Within-subject precisions were 4 ± 2, 3 ± 1, 3 ± 2, and 3 ± 2 mmHg, and within-subject variations 13 ± 6, 6 ± 3, 9 ± 4, and 7 ± 4 mmHg, indicating precision over a wide range of pressures. Group average ± SD of the NAP-IAP differences were -1 ± 7, 3 ± 6, 2 ± 6, and -3 ± 4 mmHg, meeting criteria. Differences were not related to mean arterial pressure or heart rate. CONCLUSION: Arterial blood pressure can be measured noninvasively and continuously using physiologic pressure reconstruction. Changes in pressure can be followed and values are comparable to invasive monitoring

    Noninvasive Continuous Arterial Blood Pressure Monitoring with Nexfin (R)

    No full text
    Background: If invasive measurement of arterial blood pressure is not warranted, finger cuff technology can provide continuous and noninvasive monitoring. Finger and radial artery pressures differ; Nexfin (R) (BMEYE, Amsterdam, The Netherlands) measures finger arterial pressure and uses physiologic reconstruction methodologies to obtain values comparable to invasive pressures. Methods: Intra-arterial pressure (IAP) and noninvasive Nexfin arterial pressure (NAP) were measured in cardiothoracic surgery patients, because invasive pressures are available. NAP-IAP differences were analyzed during 30 min. Tracking was quantified by within-subject precision (SD of individual NAP-IAP differences) and correlation coefficients. The ranges of pressure change were quantified by within-subject variability (SD of individual averages of NAP and IAP). Accuracy and precision were expressed as group average +/- SD of the differences and considered acceptable when smaller than 5 +/- 8 mmHg, the Association for the Advancement of Medical Instrumentation criteria. Results: NAP and IAP were obtained in 50 (34-83 yr, 40 men) patients. For systolic, diastolic, mean arterial, and pulse pressure, median (25-75 percentiles) correlation coefficients were 0.96 (0.91-0.98), 0.93 (0.87-0.96), 0.96 (0.90-0.97), and 0.94 (0.85-0.98), respectively. Within-subject precisions were 4 +/- 2, 3 +/- 1, 3 +/- 2, and 3 +/- 2 mmHg, and within-subject variations 13 +/- 6, 6 +/- 3, 9 +/- 4, and 7 +/- 4 mmHg, indicating precision over a wide range of pressures. Group average +/- SD of the NAP-IAP differences were -1 +/- 7, 3 +/- 6, 2 +/- 6, and -3 +/- 4 mmHg, meeting criteria. Differences were not related to mean arterial pressure or heart rate. Conclusion: Arterial blood pressure can be measured non-invasively and continuously using physiologic pressure reconstruction. Changes in pressure can be followed and values are comparable to invasive monitorin