    Performance assessment of a NaI(Tl) gamma counter for PET applications with methods for improved quantitative accuracy and greater standardization

    Get PDF
    BACKGROUND: Although NaI(Tl) gamma counters play an important role in many quantitative positron emission tomography (PET) protocols, their calibration for positron-emitting samples has not been standardized across imaging sites. In this study, we characterized the operational range of a gamma counter specifically for positron-emitting radionuclides, and we assessed the role of traceable (68)Ge/(68)Ga sources for standardizing system calibration. METHODS: A NaI(Tl) gamma counter was characterized with respect to count rate performance, adequacy of detector shielding, system stability, and sample volume effects using positron-emitting radionuclides (409- to 613-keV energy window). System efficiency was measured using (18)F and compared with corresponding data obtained using a long-lived (68)Ge/(68)Ga source that was implicitly traceable to a national standard. RESULTS: One percent count loss was measured at 450 × 10(3) counts per minute. Penetration of the detector shielding by 511-keV photons gave rise to a negligible background count rate. System stability tests showed a coefficient of variation of 0.13% over 100 days. For a sample volume of 4 mL, the efficiencies relative to those at 0.1 mL were 0.96, 0.94, 0.91, 0.78, and 0.72 for (11)C, (18)F, (125)I, (99m)Tc, and (51)Cr, respectively. The efficiency of a traceable (68)Ge/(68)Ga source was 30.1% ± 0.07% and was found to be in close agreement with the efficiency for (18)F after consideration of the different positron fractions. CONCLUSIONS: Long-lived (68)Ge/(68)Ga reference sources, implicitly traceable to a national metrology institute, can aid standardization of gamma counter calibration for (18)F. A characteristic feature of positron emitters meant that accurate calibration could be maintained over a wide range of sample volumes by using a narrow energy window centered on the 511-keV peak

    Feasibility of state of the art PET/CT systems performance harmonisation

    Get PDF
    Purpose The objective of this study was to explore the feasibility of harmonising performance for PET/CT systems equipped with time-of-flight (ToF) and resolution modelling/point spread function (PSF) technologies. A second aim was producing a working prototype of new harmonising criteria with higher contrast recoveries than current EARL standards using various SUV metrics. Methods Four PET/CT systems with both ToF and PSF capabilities from three major vendors were used to acquire and reconstruct images of the NEMA NU2-2007 body phantom filled conforming EANM EARL guidelines. A total of 15 reconstruction parameter sets of varying pixel size, post filtering and reconstruction type, with three different acquisition durations were used to compare the quantitative performance of the systems. A target range for recovery curves was established such that it would accommodate the highest matching recoveries from all investigated systems. These updated criteria were validated on 18 additional scanners from 16 sites in order to demonstrate the scanners' ability to meet the new target range. Results Each of the four systems was found to be capable of producing harmonising reconstructions with similar recovery curves. The five reconstruction parameter sets producing harmonising results significantly increased SUVmean (25%) and SUVmax (26%) contrast recoveries compared with current EARL specifications. Additional prospective validation performed on 18 scanners from 16 EARL accredited sites demonstrated the feasibility of updated harmonising specifications. SUVpeak was found to significantly reduce the variability in quantitative results while producing lower recoveries in smaller ( Conclusions Harmonising PET/CT systems with ToF and PSF technologies from different vendors was found to be feasible. The harmonisation of such systems would require an update to the current multicentre accreditation program EARL in order to accommodate higher recoveries. SUVpeak should be further investigated as a noise resistant alternative quantitative metric to SUVmax

    Feasibility of state of the art PET/CT systems performance harmonisation

    Get PDF
    Purpose The objective of this study was to explore the feasibility of harmonising performance for PET/CT systems equipped with time-of-flight (ToF) and resolution modelling/point spread function (PSF) technologies. A second aim was producing a working prototype of new harmonising criteria with higher contrast recoveries than current EARL standards using various SUV metrics. Methods Four PET/CT systems with both ToF and PSF capabilities from three major vendors were used to acquire and reconstruct images of the NEMA NU2-2007 body phantom filled conforming EANM EARL guidelines. A total of 15 reconstruction parameter sets of varying pixel size, post filtering and reconstruction type, with three different acquisition durations were used to compare the quantitative performance of the systems. A target range for recovery curves was established such that it would accommodate the highest matching recoveries from all investigated systems. These updated criteria were validated on 18 additional scanners from 16 sites in order to demonstrate the scanners' ability to meet the new target range. Results Each of the four systems was found to be capable of producing harmonising reconstructions with similar recovery curves. The five reconstruction parameter sets producing harmonising results significantly increased SUVmean (25%) and SUVmax (26%) contrast recoveries compared with current EARL specifications. Additional prospective validation performed on 18 scanners from 16 EARL accredited sites demonstrated the feasibility of updated harmonising specifications. SUVpeak was found to significantly reduce the variability in quantitative results while producing lower recoveries in smaller (<= 17 mm diameter) sphere sizes. Conclusions Harmonising PET/CT systems with ToF and PSF technologies from different vendors was found to be feasible. The harmonisation of such systems would require an update to the current multicentre accreditation program EARL in order to accommodate higher recoveries. SUVpeak should be further investigated as a noise resistant alternative quantitative metric to SUVmax

    Crayfish feeding preferences for fresh water macrophytes: The influence of plant structure and chemistry

    Get PDF
    The omnivorous crayfish Procambarus clarkii fed selectively on several species of macrophytes, preferring delicate fresh plants that had filamentous or finely-branched architectures. When the macrophytes were dried, powdered, and reconstituted into an alginate gel (thus eliminating among-species differences in physical characteristics). crayfish preferences were altered; previously tough plants that were high in nitrogen and protein were preferred over previously delicate plants that were low in nitrogen and protein. Even though plant structure influences feeding decision of crayfish, the structurally identical macrophyte gels were fed upon differently, demonstrating that nonstructural traits are important feeding determinants. However, plant tissue constituents such as nitrogen, protein, phenolics, lignin, cellulose, or ash were not significantly con-elated with feeding preferences. Two high-nitrogen plants that were avoided by crayfish as fresh and as reconstituted tissue (Nuphar luteum macrophyllum and Alternanthera philoxeroides) possessed extracts that reduced crayfish feeding in laboratory assays, demonstrating that macrophyte metabolites can deter some herbivores. As is often observed with large generalist herbivores and omnivores in terrestrial and marine systems, the freshwater crayfish made feeding decisions based upon multiple plant cues (structure, nutrition, chemical defenses)

    Whitehall in the Caribbean? The legacy of colonial administration for post-colonial democratic development

    Get PDF
    Colonial-era administrative institutions and doctrines are fundamental to any analysis of Westminster’s legacy in the Caribbean. Applying the lens of ‘Public Service Bargains’ (PSBs) – the formal and informal understandings of reward, competence and loyalty of public servants –we first examine constitutional and administrative doctrines regarding the public service of Crown Colonies, before analysing how these worked themselves out in Jamaica. Our analysis reveals a number of perceived deficiencies in the PSB in the pre-independence period that cast a shadow on future relations in the post-independence period

    Test-retest repeatability of organ uptake on PSMA‐targeted 18F‐DCFPyL PET/CT in patients with prostate cancer

    Get PDF
    Objectives We evaluated 18F-DCFPyL test–retest repeatability of uptake in normal organs. Methods Twenty-two prostate cancer (PC) patients underwent two 18F-DCFPyL PET scans within 7 days within a prospective clinical trial (NCT03793543). In both PET scans, uptake in normal organs (kidneys, spleen, liver, and salivary and lacrimal glands) was quantified. Repeatability was determined by using within-subject coefficient of variation (wCOV), with lower values indicating improved repeatability. Results For SUVmean, repeatability was high for kidneys, spleen, liver, and parotid glands (wCOV, range: 9.0%–14.3%) and lower for lacrimal (23.9%) and submandibular glands (12.4%). For SUVmax, however, the lacrimal (14.4%) and submandibular glands (6.9%) achieved higher repeatability, while for large organs (kidneys, liver, spleen, and parotid glands), repeatability was low (range: 14.1%–45.2%). Conclusion We found acceptable repeatability of uptake on 18F-DCFPyL PET for normal organs, in particular for SUVmean in the liver or parotid glands. This may have implications for both PSMA-targeted imaging and treatment, as patient selection for radioligand therapy and standardized frameworks for scan interpretation (PROMISE, E-PSMA) rely on uptake in those reference organs

    Lack of repeatability of radiomic features derived from PET scans: results from a 18F‐DCFPyL test–retest cohort

    Get PDF
    Objectives PET-based radiomic metrics are increasingly utilized as predictive image biomarkers. However, the repeatability of radiomic features on PET has not been assessed in a test–retest setting. The prostate-specific membrane antigen-targeted compound 18F-DCFPyL is a high-affinity, high-contrast PET agent that we utilized in a test-retest cohort of men with metastatic prostate cancer (PC). Methods Data of 21 patients enrolled in a prospective clinical trial with histologically proven PC underwent two 18F-DCFPyL PET scans within 7 days, using identical acquisition and reconstruction parameters. Sites of disease were segmented and a set of 29 different radiomic parameters were assessed on both scans. We determined repeatability of quantification by using Pearson's correlations, within-subject coefficient of variation (wCOV), and Bland–Altman analysis. Results In total, 230 lesions (177 bone, 38 lymph nodes, 15 others) were assessed on both scans. For all investigated radiomic features, a broad range of inter-scan correlation was found (r, 0.07–0.95), with acceptable reproducibility for entropy and homogeneity (wCOV, 16.0% and 12.7%, respectively). On Bland–Altman analysis, no systematic increase or decrease between the scans was observed for either parameter (±1.96 SD: 1.07/−1.30, 0.23/−0.18, respectively). The remaining 27 tested radiomic metrics, however, achieved unacceptable high wCOV (≄21.7%). Conclusion Many common radiomic features derived from a test–retest PET study had poor repeatability. Only Entropy and homogeneity achieved good repeatability, supporting the notion that those image biomarkers may be incorporated in future clinical trials. Those radiomic features based on high frequency aspects of images appear to lack the repeatability on PET to justify further study

    Effect of Point-Spread Function Reconstruction for Indeterminate PSMA-RADS-3A Lesions on PSMA-Targeted PET Imaging of Men with Prostate Cancer

    Get PDF
    Purpose: Prostate-specific membrane antigen (PSMA) positron emission tomography (PET) is emerging as an important modality for imaging patients with prostate cancer (PCa). As with any imaging modality, indeterminate findings will arise. The PSMA reporting and data system (PSMA-RADS) version 1.0 codifies indeterminate soft tissue findings with the PSMA-RADS-3A moniker. We investigated the role of point-spread function (PSF) reconstructions on categorization of PSMA-RADS-3A lesions. Methods: This was a post hoc analysis of an institutional review board approved prospective trial. Around 60 min after the administration of 333 MBq (9 mCi) of PSMA-targeted 18F-DCFPyL, patients underwent PET/computed tomography (CT) acquisitions from the mid-thighs to the skull vertex. The PET data were reconstructed with and without PSF. Scans were categorized according to PSMA-RADS version 1.0, and all PSMA-RADS-3A lesions on non-PSF images were re-evaluated to determine if any could be re-categorized as PSMA-RADS-4. The maximum standardized uptake values (SUVs) of the lesions, mean SUVs of blood pool, and the ratios of those values were determined. Results: A total of 171 PSMA-RADS-3A lesions were identified in 30 patients for whom both PSF reconstructions and cross-sectional imaging follow-up were available. A total of 13/171 (7.6%) were re-categorized as PSMA-RADS-4 lesions with PSF reconstructions. A total of 112/171 (65.5%) were found on follow-up to be true positive for PCa, with all 13 of the re-categorized lesions being true positive on follow-up. The lesions that were re-categorized trended towards having higher SUVmax-lesion and SUVmax-lesion/SUVmean-blood-pool metrics, although these relationships were not statistically significant. Conclusions: The use of PSF reconstructions for 18F-DCFPyL PET can allow the appropriate re-categorization of a small number of indeterminate PSMA-RADS-3A soft tissue lesions as more definitive PSMA-RADS-4 lesions. The routine use of PSF reconstructions for PSMA-targeted PET may be of value at those sites that utilize this technolog

    High SUVs have more robust repeatability in patients with metastatic prostate cancer: results from a prospective test-retest cohort imaged with 18F-DCFPyL

    Get PDF
    OBJECTIVES: In patients with prostate cancer (PC) receiving prostate-specific membrane antigen- (PSMA-) targeted radioligand therapy (RLT), higher baseline standardized uptake values (SUVs) are linked to improved outcome. Thus, readers deciding on RLT must have certainty on the repeatability of PSMA uptake metrics. As such, we aimed to evaluate the test-retest repeatability of lesion uptake in a large cohort of patients imaged with (18)F-DCFPyL. METHODS: In this prospective, IRB-approved trial (NCT03793543), 21 patients with history of histologically proven PC underwent two (18)F-DCFPyL PET/CTs within 7 days (mean 3.7, range 1 to 7 days). Lesions in the bone, lymph nodes (LN), and other organs were manually segmented on both scans, and uptake parameters were assessed (maximum (SUV(max)) and mean (SUV(mean)) SUVs), PSMA-tumor volume (PSMA-TV), and total lesion PSMA (TL-PSMA, defined as PSMA − TV × SUV(mean))). Repeatability was determined using Pearson's correlations, within-subject coefficient of variation (wCOV), and Bland-Altman analysis. RESULTS: In total, 230 pairs of lesions (177 bone, 38 LN, and 15 other) were delineated, demonstrating a wide range of SUV(max) (1.5–80.5) and SUV(mean) (1.4–24.8). Including all sites of suspected disease, SUVs had a strong interscan correlation (R(2) ≄ 0.99), with high repeatability for SUV(mean) and SUV(max) (wCOV, 7.3% and 12.1%, respectively). High SUVs showed significantly improved wCOV relative to lower SUVs (P < 0.0001), indicating that high SUVs are more repeatable, relative to the magnitude of the underlying SUV. Repeatability for PSMA-TV and TL-PSMA, however, was low (wCOV ≄ 23.5%). Across all metrics for LN and bone lesions, interscan correlation was again strong (R(2) ≄ 0.98). Moreover, LN-based SUV(mean) also achieved the best wCOV (3.8%), which was significantly reduced when compared to osseous lesions (7.8%, P < 0.0001). This was also noted for SUV(max) (wCOV, LN 8.8% vs. bone 12.0%, P < 0.03). On a compartment-based level, wCOVs for volumetric features were ≄22.8%, demonstrating no significant differences between LN and bone lesions (PSMA-TV, P =0.63; TL-PSMA, P =0.9). Findings on an entire tumor burden level were also corroborated in a hottest lesion analysis investigating the SUV(max) of the most intense lesion per patient (R(2), 0.99; wCOV, 11.2%). CONCLUSION: In this prospective test-retest setting, SUV parameters demonstrated high repeatability, in particular in LNs, while volumetric parameters demonstrated low repeatability. Further, the large number of lesions and wide distribution of SUVs included in this analysis allowed for the demonstration of a dependence of repeatability on SUV, with higher SUVs having more robust repeatability
    • 