87 research outputs found

    Perceptual Spaces Induced by Cochlear Implant All-Polar Stimulation Mode

    Get PDF
    It has been argued that a main limitation of the cochlear implant is the spread of current induced by each electrode, which activates an inappropriately large range of sensory neurons. To reduce this spread, an alternative stimulation mode, the all-polar mode, was tested with five participants. It was designed to activate all the electrodes simultaneously with appropriate current levels and polarities to recruit narrower regions of auditory nerves at specific intracochlear electrode positions (denoted all-polar electrodes). In this study, the all-polar mode was compared with the current commercial stimulation mode: the monopolar mode. The participants were asked to judge the sound dissimilarity between pairs of two-electrode pulse-train stimuli that differed in the electrode positions and were presented in either monopolar or all-polar mode with pulses on the two electrodes presented either sequentially or simultaneously. The dissimilarity ratings were analyzed using a multidimensional scaling technique and three-dimensional stimulus perceptual spaces were produced. For all the conditions (mode and simultaneity), the first perceptual dimension was highly correlated with the position of the most apical activated electrode of the electrical stimulation and the second dimension with the position of the most basal electrode. In both sequential and simultaneous conditions, the monopolar and all-polar stimuli were significantly separated by a third dimension, which may indicate that all-polar stimuli have a perceptual quality that differs from monopolar stimuli. Overall, the results suggest that both modes might successfully represent spectral information in a sound processing strategy

    The role of temporal cues on voluntary stream segregation in cochlear implant users

    Get PDF
    Data from "The role of temporal cues in voluntary stream segregation for cochlear implant users"This work was supported by the Oticon Centre of Excellence for Hearing and Speech Sciences (CHeSS) and the Carlsberg foundation. The research equipment was provided by Cochlear Ltd

    Auditory stream segregation can be modeled by neural competition in cochlear implant listeners

    Get PDF
    This repository contains the simulations presented in the article "Auditory stream segregation can be modeled by neural competition in cochlear implant listeners" with DOI (add DOI here) The repository contains 2 mat files and the matlab model object to handle them: pSeg__sigma_40__L_06.mat: This file contains the simulations from the neuromechanistic model with sigma = 40 and L = 0.6 pSeg__sigma_30__L_035.mat: This file contains the simulations from the neuromechanistic model with sigma = 30 and L = 0.35 PSegregated.m: This file defines the matlab model object

    The Role of Place Cues in Voluntary Stream Segregation for Cochlear Implant Users

    Get PDF
    Sequential stream segregation by cochlear implant (CI) listeners was investigated using a temporal delay detection task composed of a sequence of regularly presented bursts of pulses on a single electrode (B) interleaved with an irregular sequence (A) presented on a different electrode. In half of the trials, a delay was added to the last burst of the regular B sequence, and the listeners were asked to detect this delay. As a jitter was added to the period between consecutive A bursts, time judgments between the A and B sequences provided an unreliable cue to perform the task. Thus, the segregation of the A and B sequences should improve performance. In Experiment 1, the electrode separation and the sequence duration were varied to clarify whether place cues help CI listeners to voluntarily segregate sounds and whether a two-stream percept needs time to build up. Results suggested that place cues can facilitate the segregation of sequential sounds if enough time is provided to build up a two-stream percept. In Experiment 2, the duration of the sequence was fixed, and only the electrode separation was varied to estimate the fission boundary. Most listeners were able to segregate the sounds for separations of three or more electrodes, and some listeners could segregate sounds coming from adjacent electrodes

    Perceptual Interactions Between Electrodes Using Focused and Monopolar Cochlear Stimulation

    Get PDF
    In today’s cochlear implant (CI) systems, the monopolar (MP) electrode configuration is the most commonly used stimulation mode, requiring only a single current source. However, with an implant that will allow simultaneous activation of multiple independent current sources, it is possible to implement an all-polar (AP) stimulation mode designed to create a focused electrical field. The goal of this experiment was to study the potential benefits of this all-polar mode for reducing uncontrolled electrode interactions compared with the monopolar mode. The five participants who took part in the study were implanted with a research device that was connected via a percutaneous connector to a benchtop stimulator providing 22 independent current sources. The perceptual effects of the AP mode were tested in three experiments. In Experiment 1, the current level difference between loudness-matched sequential and simultaneous stimuli composed of 2 spatially separated pulse trains was measured as function of the electrode separation. Results indicated a strong current-summation interaction for simultaneous stimuli in the MP mode for separations up to at least 4.8 mm. No significant interaction was found in the AP mode beyond a separation of 2.4 mm. In Experiment 2, a forward-masking paradigm was used with fixed equally loud probes in AP and MP modes, and AP maskers presented on different electrode positions. Results indicated a similar spatial masking pattern between modes. In Experiment 3, subjects were asked to discriminate between across-electrode temporal delays. It was hypothesized that discrimination would decrease with electrode separation faster in AP compared to MP modes. However, results showed no difference between the two modes. Overall, the results indicated that the AP mode produced less current spread than MP mode but did not lead to a significant advantage in terms of spread of neuronal excitation at equally loud levels
    • …
    corecore