163 research outputs found

    Clinical experience with a multifunctional, flexible surgery system for endolumenal, single-port, and NOTES procedures

    Get PDF
    Single-port and incisionless surgical approaches hold the promise of fewer complications, reduced pain, faster recovery, and improved cosmesis compared with traditional open or laparoscopic approaches. The ability to select an access approach (i.e., endolumenal, single-port, transvaginal, or transgastric) with one platform may be important to optimization of individual patient results. The authors report their results using these four separate surgical approaches tailored to three different therapeutic procedures, all with the use of a single flexible platform, the Incisionless Operating Platform (IOP). After institutional review board approval, the IOP was used to perform nine cholecystectomies via transvaginal (TV) (n = 4), transgastric (TG) (n = 4), and single-port transumbilical (TU) (n = 1) access. Two appendectomies were performed via TG access. Endolumenal access was used for 18 gastric pouch and stoma reductions after Roux-en-Y gastric bypass. The TG and TV procedures involved the use of one to three trocars. The recorded data included safety, procedural success, operative time, patient pain assessment (on a 0–10 scale) at discharge, and length of hospital stay. Procedural success was achieved for 16 of 18 endolumenal procedures, 1 of 1 single-port procedure, and 10 of 10 NOTES procedures. For 5 of 10 NOTES procedures, only one small trocar was required. The mean operative times were 79 min for pouch with stoma reduction, 171 min for cholecystectomy, and 274 min for appendectomy. Of 29 patients, 27 were discharged in 24 h or less. The average pain scores were 0.44 for pouch with stoma reduction, 1.3 for cholecystectomy, and 2.5 for appendectomy. No significant complications occurred. The ergonomics of IOP allowed the surgeon to interface with the system using an endoscopic or laparoscopic orientation. Availability of a multifunctional, flexible surgery platform provides a choice of a single-port or incisionless surgical approach with the potential to reduce complications, pain, and recovery time while improving cosmesis

    A review for clinical outcomes research: hypothesis generation, data strategy, and hypothesis-driven statistical analysis

    Get PDF
    In recent years, more and more large, population-level databases have become available for clinical research. The size and complexity of these databases often present a methodological challenge for investigators. We propose that a “protocol” may facilitate the research process using these databases. In addition, much like the structured History and Physical (H&P) helps the audience appreciate the details of a patient case more systematically, a formal outcomes research protocol can also help in the systematic evaluation of an outcomes research manuscript

    Morbid Obesity with Achalasia: A Surgical Challenge

    Get PDF
    Achalasia is a relatively rare medical condition that is classically not associated with obesity. The surgical treatment of a simultaneous occurrence of these two diseases requires careful consideration, and only a few reports can be found in the literature combining a Heller myotomy with gastric bypass, duodenal switch, or gastric banding. We report the case of a 69-year-old female patient with early achalasia and obesity who underwent simultaneous laparoscopic gastric sleeve resection and robotic Heller myotomy. No intra- or postoperative complications occurred. A follow-up at 6 weeks showed a significant weight loss and resolved symptoms of achalasia. The case illustrates that a simultaneous gastric sleeve resection and robotic Heller myotomy might be an option for the treatment of concurrent obesity and achalasia

    The inflammatory response in transgastric surgery: gastric content leak leads to localized inflammatory response and higher adhesive disease

    Get PDF
    Risk of gastric spillage during transgastric surgery is a potential complication of NOTES procedures. The aim of this study was to determine risk outcomes from gastric spillage in a rat survival model by measuring local and systemic inflammatory markers, adhesive disease, and morbidity. We performed a minilaparotomy with needle aspiration of 2 ml of gastric contents mixed with 2 ml of sterile saline (study group, SG) or 4 ml of sterile saline (control group, CG) injected into the peritoneal cavity of 60 male rats. Inflammatory markers (TNFα, IL-6, and IL-10) were analyzed at 1, 3, 6, and 24 h postoperatively by obtaining plasma levels and peritoneal washings. At necropsy, the peritoneal cavity was examined grossly for adhesions. Adhesions were seen more frequently in the SG versus the CG (100% vs. 33.3%, p < 0.014). There was a significant difference in the peritoneal TNFα levels in the SG compared with the CG, which peaked 1 h after surgery (p < 0.02). Both peritoneal IL-6 and IL-10 levels were higher in the SG versus the CG, which peaked 3 h after surgery (p < 0.005 and p < 0.001, respectively). All peritoneal inflammatory markers returned to undetectable levels at 24 h for both groups. Plasma cytokines were undetectable at all time intervals. The inflammatory response was found to be a localized and not systemic event, with plasma cytokine levels remaining normal while peritoneal washings revealed a brisk, short-lived localized inflammatory response. There was a significantly higher rate of adhesive disease in the SG compared with the CG; this, however did not translate into a difference in apparent clinical outcome. We conclude that gastric leakage in this NOTES rodent model induces a localized inflammatory response, followed by mild to moderate adhesive disease. This may be important in human NOTES

    SAGES consensus recommendations on surgical video data use, structure, and exploration (for research in artificial intelligence, clinical quality improvement, and surgical education)

    Get PDF
    BACKGROUND: Surgery generates a vast amount of data from each procedure. Particularly video data provides significant value for surgical research, clinical outcome assessment, quality control, and education. The data lifecycle is influenced by various factors, including data structure, acquisition, storage, and sharing; data use and exploration, and finally data governance, which encompasses all ethical and legal regulations associated with the data. There is a universal need among stakeholders in surgical data science to establish standardized frameworks that address all aspects of this lifecycle to ensure data quality and purpose. METHODS: Working groups were formed, among 48 representatives from academia and industry, including clinicians, computer scientists and industry representatives. These working groups focused on: Data Use, Data Structure, Data Exploration, and Data Governance. After working group and panel discussions, a modified Delphi process was conducted. RESULTS: The resulting Delphi consensus provides conceptualized and structured recommendations for each domain related to surgical video data. We identified the key stakeholders within the data lifecycle and formulated comprehensive, easily understandable, and widely applicable guidelines for data utilization. Standardization of data structure should encompass format and quality, data sources, documentation, metadata, and account for biases within the data. To foster scientific data exploration, datasets should reflect diversity and remain adaptable to future applications. Data governance must be transparent to all stakeholders, addressing legal and ethical considerations surrounding the data. CONCLUSION: This consensus presents essential recommendations around the generation of standardized and diverse surgical video databanks, accounting for multiple stakeholders involved in data generation and use throughout its lifecycle. Following the SAGES annotation framework, we lay the foundation for standardization of data use, structure, and exploration. A detailed exploration of requirements for adequate data governance will follow

    Fluorescence laparoscopy imaging of pancreatic tumor progression in an orthotopic mouse model

    Get PDF
    The use of fluorescent proteins to label tumors is revolutionizing cancer research, enabling imaging of both primary and metastatic lesions, which is important for diagnosis, staging, and therapy. This report describes the use of fluorescence laparoscopy to image green fluorescent protein (GFP)-expressing tumors in an orthotopic mouse model of human pancreatic cancer. The orthotopic mouse model of human pancreatic cancer was established by injecting GFP-expressing MiaPaCa-2 human pancreatic cancer cells into the pancreas of 6-week-old female athymic mice. On postoperative day 14, diagnostic laparoscopy using both white and fluorescent light was performed. A standard laparoscopic system was modified by placing a 480-nm short-pass excitation filter between the light cable and the laparoscope in addition to using a 2-mm-thick emission filter. A camera was used that allowed variable exposure time and gain setting. For mouse laparoscopy, a 3-mm 0° laparoscope was used. The mouse’s abdomen was gently insufflated to 2 mm Hg via a 22-gauge angiocatheter. After laparoscopy, the animals were sacrificed, and the tumors were collected and processed for histologic review. The experiments were performed in triplicate. Fluorescence laparoscopy enabled rapid imaging of the brightly fluorescent tumor in the pancreatic body. Use of the proper filters enabled simultaneous visualization of the tumor and the surrounding structures with minimal autofluorescence. Fluorescence laparoscopy thus allowed exact localization of the tumor, eliminating the need to switch back and forth between white and fluorescence lighting, under which the background usually is so darkened that it is difficult to maintain spatial orientation. The use of fluorescence laparoscopy permits the facile, real-time imaging and localization of tumors labeled with fluorescent proteins. The results described in this report should have important clinical potential

    Natural orifice surgery: initial clinical experience

    Get PDF
    Natural orifice translumenal endoscopic surgery (NOTES) has moved quickly from preclinical investigation to clinical implementation. However, several major technical problems limit clinical NOTES including safe access, retraction and dissection of the gallbladder, and clipping of key structures. This study aimed to identify challenges and develop solutions for NOTES during the initial clinical experience. Under an Institutional Review Board (IRB)-approved protocol, patients consented to a natural orifice operation for removal of either the gallbladder or the appendix via either the vagina or the stomach using a single umbilical trocar for safety and assistance. Nine transvaginal cholecystectomies, one transgastric appendectomy, and one transvaginal appendectomy have been completed to date. All but one patient were discharged on postoperative day 1 as per protocol. No complications occurred. The limited initial evidence from this study demonstrates that NOTES is feasible and safe. The addition of an umbilical trocar is a bridge allowing safe performance of NOTES procedures until better instruments become available. The addition of a flexible long grasper through the vagina and a flexible operating platform through the stomach has enabled the performance of NOTES in a safe and easily reproducible manner. The use of a uterine manipulator has facilitated visualization of the cul de sac in women with a uterus to allow for safe transvaginal access

    Cessation of alcohol drinking, tobacco smoking and the reversal of head and neck cancer risk

    Get PDF
    Background Quitting tobacco or alcohol use has been reported to reduce the head and neck cancer risk in previous studies. However, it is unclear how many years must pass following cessation of these habits before the risk is reduced, and whether the risk ultimately declines to the level of never smokers or never drinkers. Methods We pooled individual-level data from case-control studies in the International Head and Neck Cancer Epidemiology Consortium. Data were available from 13 studies on drinking cessation (9167 cases and 12 593 controls), and from 17 studies on smoking cessation (12 040 cases and 16 884 controls). We estimated the effect of quitting smoking and drinking on the risk of head and neck cancer and its subsites, by calculating odds ratios (ORs) using logistic regression models. Results Quitting tobacco smoking for 1-4 years resulted in a head and neck cancer risk reduction [OR 0.70, confidence interval (CI) 0.61-0.81 compared with current smoking], with the risk reduction due to smoking cessation after ≥20 years (OR 0.23, CI 0.18-0.31), reaching the level of never smokers. For alcohol use, a beneficial effect on the risk of head and neck cancer was only observed after ≥20 years of quitting (OR 0.60, CI 0.40-0.89 compared with current drinking), reaching the level of never drinkers. Conclusions Our results support that cessation of tobacco smoking and cessation of alcohol drinking protect against the development of head and neck cance
    corecore