    High resolution ion chamber array delivery quality assurance for robotic radiosurgery: commissioning and validation

    Get PDF
    AbstractPurposeHigh precision radiosurgery demands comprehensive delivery-quality-assurance techniques. The use of a liquid-filled ion-chamber-array for robotic-radiosurgery delivery-quality-assurance was investigated and validated using several test scenarios and routine patient plans.Methods and materialPreliminary evaluation consisted of beam profile validation and analysis of source–detector-distance and beam-incidence-angle response dependence. The delivery-quality-assurance analysis is performed in four steps: (1) Array-to-plan registration, (2) Evaluation with standard Gamma-Index criteria (local-dose-difference⩽2%, distance-to-agreement⩽2mm, pass-rate⩾90%), (3) Dose profile alignment and dose distribution shift until maximum pass-rate is found, and (4) Final evaluation with 1mm distance-to-agreement criterion. Test scenarios consisted of intended phantom misalignments, dose miscalibrations, and undelivered Monitor Units. Preliminary method validation was performed on 55 clinical plans in five institutions.ResultsThe 1000SRS profile measurements showed sufficient agreement compared with a microDiamond detector for all collimator sizes. The relative response changes can be up to 2.2% per 10cm source–detector-distance change, but remains within 1% for the clinically relevant source–detector-distance range. Planned and measured dose under different beam-incidence-angles showed deviations below 1% for angles between 0° and 80°. Small-intended errors were detected by 1mm distance-to-agreement criterion while 2mm criteria failed to reveal some of these deviations. All analyzed delivery-quality-assurance clinical patient plans were within our tight tolerance criteria.ConclusionWe demonstrated that a high-resolution liquid-filled ion-chamber-array can be suitable for robotic radiosurgery delivery-quality-assurance and that small errors can be detected with tight distance-to-agreement criterion. Further improvement may come from beam specific correction for incidence angle and source–detector-distance response

    Usability and accuracy of high-resolution detectors for daily quality assurance for robotic radiosurgery

    Get PDF
    For daily CyberKnife QA a Winston-Lutz-Test (Automated-Quality-Assurance, AQA) is used to determine sub-millimeter deviations in beam delivery accuracy. This test is performed using gafchromic film, an extensive and user-dependent method requiring the use of disposables. We therefore analyzed the usability and accuracy of high-resolution detector arrays. We analyzed a liquid-filled ionization-chamber array (Octavius 1000SRS, PTW, Germany), which has a central resolution of 2.5mm. To test sufficient sensitivity, beam profiles with robot shifts of 0.1mm along the arrays' axes were measured. The detected deviation between the shifted and central profile were compared to the real robot's position. We then compared the results to the SRS-Profiler (SunNuclear, USA) with 4.0mm resolution and to the Nonius (QUART, Germany), a single-line diode detector with 2.8mm resolution. Finally, AQA variance and usability were analyzed performing a number of AQA tests over time, which required the use of specially designed fixtures for each array, and the results were compared to film. Concerning sensitivity, the 1000SRS detected the beam profile shifts with a maximum difference of 0.11mm (mean deviation = 0.03mm) compared to the actual robot shift. The Nonius and SRS-Profiler showed differences of up to 0.15mm and 0.69mm with mean deviation of 0.05mm and 0.18mm, respectively. Analyzing the variation of AQA results over time, the 1000SRS showed a comparable standard deviation to film (0.26mm vs. 0.18mm). The SRS-Profiler and the Nonius showed a standard deviation of 0.16mm and 0.24mm, respectively. The 1000SRS seems to provide equivalent accuracy and sensitivity to the gold standard film when performing daily AQA tests. Compared to other detectors in our study the sensitivity as well as the accuracy of the 1000SRS appears to be superior and more user-friendly. Furthermore, no significant modification of the standard AQA procedure is required when introducing 1000SRS for CyberKnife AQA

    Usability and accuracy of high-resolution detectors for daily quality assurance for robotic radiosurgery

    No full text
    For daily CyberKnife QA a Winston-Lutz-Test (Automated-Quality-Assurance, AQA) is used to determine sub-millimeter deviations in beam delivery accuracy. This test is performed using gafchromic film, an extensive and user-dependent method requiring the use of disposables. We therefore analyzed the usability and accuracy of high-resolution detector arrays. We analyzed a liquid-filled ionization-chamber array (Octavius 1000SRS, PTW, Germany), which has a central resolution of 2.5mm. To test sufficient sensitivity, beam profiles with robot shifts of 0.1mm along the arrays' axes were measured. The detected deviation between the shifted and central profile were compared to the real robot's position. We then compared the results to the SRS-Profiler (SunNuclear, USA) with 4.0mm resolution and to the Nonius (QUART, Germany), a single-line diode detector with 2.8mm resolution. Finally, AQA variance and usability were analyzed performing a number of AQA tests over time, which required the use of specially designed fixtures for each array, and the results were compared to film. Concerning sensitivity, the 1000SRS detected the beam profile shifts with a maximum difference of 0.11mm (mean deviation = 0.03mm) compared to the actual robot shift. The Nonius and SRS-Profiler showed differences of up to 0.15mm and 0.69mm with mean deviation of 0.05mm and 0.18mm, respectively. Analyzing the variation of AQA results over time, the 1000SRS showed a comparable standard deviation to film (0.26mm vs. 0.18mm). The SRS-Profiler and the Nonius showed a standard deviation of 0.16mm and 0.24mm, respectively. The 1000SRS seems to provide equivalent accuracy and sensitivity to the gold standard film when performing daily AQA tests. Compared to other detectors in our study the sensitivity as well as the accuracy of the 1000SRS appears to be superior and more user-friendly. Furthermore, no significant modification of the standard AQA procedure is required when introducing 1000SRS for CyberKnife AQA

    Long-term survival of patients with CLL after allogeneic transplantation: A report from the European Society for Blood and Marrow Transplantation

    Get PDF
    Even with the availability of targeted drugs, allogeneic hematopoietic cell transplantation (allo-HCT) is the only therapy with curative potential for patients with CLL. Cure can be assessed by comparing long-term survival of patients to the matched general population. Using data from 2589 patients who received allo-HCT between 2000 and 2010, we used landmark analyses and methods from relative survival analysis to calculate excess mortality compared with an age-, sex- and calendar year-matched general population. Estimated event-free survival, overall survival and non-relapse mortality (NRM) 10 years after allo-HCT were 28% (95% confidence interval (CI), 25-31), 35% (95% CI, 32-38) and 40% (95% CI, 37-42), respectively. Patients who passed the 5-year landmark event-free survival (N=394) had a 79% probability (95% CI, 73-85) of surviving the subsequent 5 years without an event. Relapse and NRM contributed equally to treatment failure. Five-year mortality for 45- and 65-year-old reference patients who were event-free at the 5-year landmark was 8% and 47% compared with 3% and 14% in the matched general population, respectively. The prospect of long-term disease-free survival remains an argument to consider allo-HCT for young patients with high-risk CLL, and programs to understand and prevent late causes of failure for long-term survivors are warranted, especially for older patients
    corecore