5 research outputs found

    Prospective Assessment of the Diagnostic Accuracy of Instantaneous Wave-Free Ratio to Assess Coronary Stenosis Relevance: Results of ADVISE II International, Multicenter Study (ADenosine Vasodilator Independent Stenosis Evaluation II)

    Get PDF
    Objectives: The purpose of this study was to assess the diagnostic accuracy of the instantaneous wave-free ratio (iFR) to characterize, outside of a pre-specified range of values, stenosis severity, as defined by fractional flow reserve (FFR) ≤0.80, in a prospective, independent, controlled, core laboratory–based environment. Background: Studies with methodological heterogeneity have reported some discrepancies in the classification agreement between iFR and FFR. The ADVISE II (ADenosine Vasodilator Independent Stenosis Evaluation II) study was designed to overcome limitations of previous iFR versus FFR comparisons. Methods: A total of 919 intermediate coronary stenoses were investigated during baseline and hyperemia. From these, 690 pressure recordings (n = 598 patients) met core laboratory physiology criteria and are included in this report. Results: The pre-specified iFR cut-off of 0.89 was optimal for the study and correctly classified 82.5% of the stenoses, with a sensitivity of 73.0% and specificity of 87.8% (C statistic: 0.90 [95% confidence interval (CI): 0.88 to 0.92, p < 0.001]). The proportion of stenoses properly classified by iFR outside of the pre-specified treatment (≤0.85) and deferral (≥0.94) values was 91.6% (95% CI: 88.8% to 93.9%). When combined with FFR use within these cut-offs, the percent of stenoses properly classified by such a pre-specified hybrid iFR-FFR approach was 94.2% (95% CI: 92.2% to 95.8%). The hybrid iFR-FFR approach obviated vasodilators from 65.1% (95% CI: 61.1% to 68.9%) of patients and 69.1% (95% CI: 65.5% to 72.6%) of stenoses. Conclusions: The ADVISE II study supports, on the basis rigorous methodology, the diagnostic value of iFR in establishing the functional significance of coronary stenoses, and highlights its complementariness with FFR when used in a hybrid iFR-FFR approach. (ADenosine Vasodilator Independent Stenosis Evaluation II–ADVISE II; NCT01740895

    PHENIX detector overview

    No full text
    The PHENIX detector is designed to perform a broad study of A-A, p-A, and p-p collisions to investigate nuclear matter under extreme conditions. A wide variety of probes, sensitive to all timescales, are used to study systematic variations with species and energy as well as to measure the spin structure of the nucleon. Designing for the needs of the heavy-ion and polarized-proton programs has produced a detector with unparalleled capabilities. PHENIX measures electron and muon pairs, photons, and hadrons with excellent energy and momentum resolution. The detector consists of a large number of subsystems that are discussed in other papers in this volume. The overall design parameters of the detector are presented. (C) 2002 Elsevier Science B.V. All rights reserved

    Evolution over Time of Ventilatory Management and Outcome of Patients with Neurologic Disease∗

    No full text
    OBJECTIVES: To describe the changes in ventilator management over time in patients with neurologic disease at ICU admission and to estimate factors associated with 28-day hospital mortality. DESIGN: Secondary analysis of three prospective, observational, multicenter studies. SETTING: Cohort studies conducted in 2004, 2010, and 2016. PATIENTS: Adult patients who received mechanical ventilation for more than 12 hours. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Among the 20,929 patients enrolled, we included 4,152 (20%) mechanically ventilated patients due to different neurologic diseases. Hemorrhagic stroke and brain trauma were the most common pathologies associated with the need for mechanical ventilation. Although volume-cycled ventilation remained the preferred ventilation mode, there was a significant (p &lt; 0.001) increment in the use of pressure support ventilation. The proportion of patients receiving a protective lung ventilation strategy was increased over time: 47% in 2004, 63% in 2010, and 65% in 2016 (p &lt; 0.001), as well as the duration of protective ventilation strategies: 406 days per 1,000 mechanical ventilation days in 2004, 523 days per 1,000 mechanical ventilation days in 2010, and 585 days per 1,000 mechanical ventilation days in 2016 (p &lt; 0.001). There were no differences in the length of stay in the ICU, mortality in the ICU, and mortality in hospital from 2004 to 2016. Independent risk factors for 28-day mortality were age greater than 75 years, Simplified Acute Physiology Score II greater than 50, the occurrence of organ dysfunction within first 48 hours after brain injury, and specific neurologic diseases such as hemorrhagic stroke, ischemic stroke, and brain trauma. CONCLUSIONS: More lung-protective ventilatory strategies have been implemented over years in neurologic patients with no effect on pulmonary complications or on survival. We found several prognostic factors on mortality such as advanced age, the severity of the disease, organ dysfunctions, and the etiology of neurologic disease
    corecore