78 research outputs found

    A Semi-Active Control Technique through MR Fluid Dampers for Seismic Protection of Single-Story RC Precast Buildings

    Get PDF
    The work proposes an innovative solution for the reduction of seismic effects on precast reinforced concrete (RC) structures. It is a semi-active control system based on the use of magnetorheological dampers. The special base restraint is remotely and automatically controlled according to a control algorithm, which modifies the dissipative capability of the structure as a function of an instantaneous dynamic response. The aim is that of reducing the base bending moment demand without a significant increase in the top displacement response. A procedure for the optimal calibration of the parameters involved in the control logic is also proposed. Non-linear modelling of a case-study structure has been performed in the OpenSees environment, also involving the specific detailing of a novel variable base restraint. Non-linear time history analyses against natural earthquakes allowed testing of the optimization procedure for the control algorithm parameters, finally the capability of the proposed technology to mitigate seismic risk of new or existing one-story precast RC structures is highlighted

    Experimental Assessment of a Skyhook Semiactive Strategy for Seismic Vibration Control of a Steel Structure

    Get PDF
    Sky-hook damping is one of the most promising techniques for feedback control of structural vibrations. It is based on the idea of connecting the structure to an ideal fixed point of the space through passive dissipative devices. Herein the benefit of semiactive (SA) sky-hook (SH) damping is investigated for seismic protection of a two-storey steel frame via shaking table tests. This kind of SA control is achieved implementing a continuous monitoring of selected structural response parameters and using variable dampers. The damping properties of the latter are changed in real-time so as to make the force provided by the damper match the desired SH damping force as closely as possible. To this aim, two prototype magnetorheological dampers have been installed at the first level of the frame and remotely driven by a SH controller. The effectiveness of the control strategy is measured as response to reduction in terms of floor accelerations and interstory drift in respect to the uncontrolled configuration. Two different calibrations of the SH controller have been tested. The experimental results are deeply discussed in order to identify the optimal one and understand the motivations of its better performance

    Experimental Issues in Testing a Semiactive Technique to Control Earthquake Induced Vibration

    Get PDF
    This work focuses on the issues to deal with when approaching experimental testing of structures equipped with semiactive control (SA) systems. It starts from practical experience authors gained in a recent wide campaign on a large scale steel frame structure provided with a control system based on magnetorheological dampers. The latter are special devices able to achieve a wide range of physical behaviours using low-power electrical currents. Experimental activities involving the use of controllable devices require special attention in solving specific aspects that characterize each of the three phases of the SA control loop: acquisition, processing, and command. Most of them are uncommon to any other type of structural testing. This paper emphasizes the importance of the experimental assessment of SA systems and shows how many problematic issues likely to happen in real applications are also present when testing these systems experimentally. This paper highlights several problematic aspects and illustrates how they can be addressed in order to achieve a more realistic evaluation of the effectiveness of SA control solutions. Undesired and unavoidable effects like delays and control malfunction are also remarked. A discussion on the way to reduce their incidence is also offered

    The health monitoring system of an isolated religious building in Italy

    No full text
    The "Our Lady of Tears Shrine" in Syracuse is one of the few seismically isolated worship structures in Italy, and has been recently included in the Italian network of structures permanently monitored by the Italian Department of Civil Protection within the Seismic Observatory of Structure (OSS). After a brief presentation of the Sanctuary and the objectives of OSS, the sensors installed in the structure and the digital dynamic acquisition system are shown together with the dedicated software for processing and management of data, and with the first data acquired from the continuous monitoring of the structure under thermal variations. Finally, a detailed finite element model of the Sanctuary has been developed in order to perform a reliable dynamical identification and seismic investigation
    • …
    corecore