11 research outputs found

    Proposal for the standardisation of multi-centre trials in nuclear medicine imaging: prerequisites for a European 123I-FP-CIT SPECT database.

    No full text
    A framework has been designed to produce high-quality data for multi-centre SPECT studies. This framework has been successfully applied to a pan-European initiative to acquire a healthy control dopamine transporter image database

    Proposal for the standardisation of multi-centre trials in nuclear medicine imaging: prerequisites for a European I-123-FP-CIT SPECT database

    No full text
    Purpose Multi-centre trials are an important part of proving the efficacy of procedures, drugs and interventions. Imaging components in such trials are becoming increasingly common; however, without sufficient control measures the usefulness of these data can be compromised. This paper describes a framework for performing high-quality multi-centre trials with single photon emission computed tomography (SPECT), using a pan-European initiative to acquire a normal control dopamine transporter brain scan database as an example.status: publishe

    Calibration of gamma camera systems for a multicentre European (123)I-FP-CIT SPECT normal database

    No full text
    PURPOSE: A joint initiative of the European Association of Nuclear Medicine (EANM) Neuroimaging Committee and EANM Research Ltd. aimed to generate a European database of [(123)I]FP-CIT single photon emission computed tomography (SPECT) scans of healthy controls. This study describes the characterization and harmonization of the imaging equipment of the institutions involved. METHODS: (123)I SPECT images of a striatal phantom filled with striatal to background ratios between 10:1 and 1:1 were acquired on all the gamma cameras with absolute ratios measured from aliquots. The images were reconstructed by a core lab using ordered subset expectation maximization (OSEM) without corrections (NC), with attenuation correction only (AC) and additional scatter and septal penetration correction (ACSC) using the triple energy window method. A quantitative parameter, the simulated specific binding ratio (sSBR), was measured using the "Southampton" methodology that accounts for the partial volume effect and compared against the actual values obtained from the aliquots. Camera-specific recovery coefficients were derived from linear regression and the error of the measurements was evaluated using the coefficient of variation (COV). RESULTS: The relationship between measured and actual sSBRs was linear across all systems. Variability was observed between different manufacturers and, to a lesser extent, between cameras of the same type. The NC and AC measurements were found to underestimate systematically the actual sSBRs, while the ACSC measurements resulted in recovery coefficients close to 100% for all cameras (AC range 69-89%, ACSC range 87-116%). The COV improved from 46% (NC) to 32% (AC) and to 14% (ACSC) (p < 0.001). CONCLUSION: A satisfactory linear response was observed across all cameras. Quantitative measurements depend upon the characteristics of the SPECT systems and their calibration is a necessary prerequisite for data pooling. Together with accounting for partial volume, the correction for scatter and septal penetration is essential for accurate quantification.status: publishe

    Calibration of gamma camera systems for a multicentre European ¹²³I-FP-CIT SPECT normal database.

    No full text
    A satisfactory linear response was observed across all cameras. Quantitative measurements depend upon the characteristics of the SPECT systems and their calibration is a necessary prerequisite for data pooling. Together with accounting for partial volume, the correction for scatter and septal penetration is essential for accurate quantification

    Comparison of coronary flow reserve estimated by dynamic radionuclide SPECT and multi-detector x-ray CT

    No full text
    Background: Recent technical advances in multi-detector computed tomography (MDCT) allow for assessment of coronary flow reserve (CFR). We compared regional CFR by dynamic SPECT and by dynamic MDCT in patients with suspected or known coronary artery disease (CAD). Methods: Thirty-five patients, (29 males, mean age 69 years) with greater than average Framingham risk of CAD, underwent dipyridamole vasodilator stress imaging. CFR was estimated using dynamic SPECT and dynamic MDCT imaging in the same patients. Myocardial perfusion findings were correlated with obstructive CAD ( 6550% luminal narrowing) on CT coronary angiography (CA). Results: Mean CFR estimated by SPECT and MDCT in 595 myocardial segments was not different (1.51 \ub1 0.46 vs. 1.50 \ub1 0.37, p = NS). Correlation of segmental CFR by SPECT and MDCT was fair (r2 = 0.39, p &lt; 0.001). Bland-Altman analysis revealed that MDCT in comparison to SPECT systematically underestimated CFR in higher CFR ranges. By CTCA, 12 patients had normal CA, 11 had non-obstructive, and 12 had obstructive CAD. CFR by both techniques was significantly higher in territories of normal CA than in territories subtended by non-obstructive or obstructive CAD. SPECT CFR was also significantly different in territories subtended by non-obstructive and obstructive CAD, whereas MDCT CFR was not. Conclusion: Despite relative underestimation of high CFR values, MDCT CFR shows promise for assessing the pathophysiological significance of anatomic CAD

    Higher-order connections between stereotyped subsets: implications for improved patient classification in CLL

    Get PDF
    Chronic lymphocytic leukemia (CLL) is characterized by the existence of subsets of patients with (quasi)identical, stereotyped B cell receptor immunoglobulins (BcR IG). Patients in certain major stereotyped subsets often display remarkably consistent clinicobiological profiles, suggesting that the study of BcR IG stereotypy in CLL has important implications for understanding disease pathophysiology and refining clinical decision-making. Nevertheless, several issues remain open, especially pertaining to the actual frequency of BcR IG stereotypy and major subsets, as well as the existence of higher-order connections between individual subsets. In order to address these issues, we investigated clonotypic IGHV-IGHD-IGHJ gene rearrangements in a series of 29,856 patients with CLL, by far the largest series worldwide. We report that the stereotyped fraction of CLL peaks at 41% of the entire cohort and that all 19 previously identified major subsets retained their relative size and ranking, while 10 new ones emerged; overall, major stereotyped subsets had a cumulative frequency of 13.5%. Higher-level relationships were evident between subsets, particularly for major stereotyped subsets with unmutated IGHV genes (U-CLL), for which close relations with other subsets, termed 'satellites', were identified. Satellite subsets accounted for 3% of the entire cohort. These results confirm our previous notion that major subsets can be robustly identified and are consistent in relative size, hence representing distinct disease variants amenable to compartmentalized research with the potential of overcoming the pronounced heterogeneity of CLL. Furthermore, the existence of satellite subsets reveals a novel aspect of repertoire restriction with implications for refined molecular classification of CLL
    corecore