20 research outputs found

    Differential Kinobeads Profiling for Target Identification of Irreversible Kinase Inhibitors

    No full text
    Chemoproteomics profiling of kinase inhibitors with kinobeads enables the assessment of inhibitor potency and selectivity for endogenously expressed protein kinases in cell lines and tissues. Using a small panel of targeted covalent inhibitors, we demonstrate the importance of measuring covalent target binding in live cells. We present a differential kinobeads profiling strategy for covalent kinase inhibitors where a compound is added either to live cells or to a cell extract that enables the comprehensive assessment of inhibitor selectivity for covalent and noncovalent targets. We found that Acalabrutinib, CC-292, and Ibrutinib potently and covalently bind TEC family kinases, but only Ibrutinib also potently binds to BLK. ZAK was identified as a submicromolar affinity Ibrutinib off-target due to covalent modification of Cys22. In contrast to Ibrutinib, 5Z-7-Oxozeaenol reacted with Cys150 next to the DFG loop, demonstrating an alternative route to covalent inactivation of this kinase, e.g., to inhibit canonical TGF-β dependent processes

    Chemoproteomics Reveals Time-Dependent Binding of Histone Deacetylase Inhibitors to Endogenous Repressor Complexes

    No full text
    Class I histone deacetylases (HDACs) are attractive drug targets in oncology and inflammation. However, the development of selective inhibitors is complicated by the characteristic that the localization, activity, and selectivity of class I HDACs are regulated by association in megadalton repressor complexes. There is emerging evidence that isoform and protein complex selectivity can be achieved by aminobenzamide inhibitors. Here we present a chemoproteomics strategy for the determination of time-dependent inhibitor binding to endogenous HDACs and HDAC complexes. This approach enabled us to determine kinetic association and dissociation rates for endogenously expressed repressor complexes. We found that unlike hydroxamate type inhibitors, aminobenzamides exhibited slow binding kinetics dependent on association within protein complexes. These findings were in agreement with a delayed cellular response on acetylation levels of distinct histone sites and the inability of aminobenzamides to inhibit HDAC activity of a Sin3 complex isolated from K562 cells

    High-Resolution Enabled TMT 8‑plexing

    No full text
    Isobaric mass tag-based quantitative proteomics strategies such as iTRAQ and TMT utilize reporter ions in the low-mass range of tandem MS spectra for relative quantification. The number of samples that can be compared in a single experiment (multiplexing) is limited by the number of different reporter ions that can be generated by differential stable isotope incorporation (<sup>15</sup>N, <sup>13</sup>C) across the reporter and the mass balancing parts of the reagents. Here, we demonstrate that a higher multiplexing rate can be achieved by utilizing the 6 mDa mass difference between <sup>15</sup>N- and <sup>13</sup>C-containing reporter fragments, in combination with high-resolution mass spectrometry. Two variants of the TMT127 and TMT129 reagents are available; these are distinguished by the position and the nature of the incorporated stable isotope in the reporter portions of the labels (TMT127L, <sup>12</sup>C<sub>8</sub>H<sub>16</sub><sup>15</sup>N<sub>1</sub><sup>+</sup>; TMT127H, <sup>12</sup>C<sub>7</sub><sup>13</sup>C<sub>1</sub>H<sub>16</sub><sup>14</sup>N<sub>1</sub><sup>+</sup>; TMT129L, <sup>12</sup>C<sub>6</sub><sup>13</sup>C<sub>2</sub>H<sub>16</sub><sup>15</sup>N<sub>1</sub><sup>+</sup>; and TMT129H, <sup>12</sup>C<sub>5</sub><sup>13</sup>C<sub>3</sub>H<sub>16</sub><sup>14</sup>N<sub>1</sub><sup>+</sup>). We demonstrate that these variants can be baseline-resolved in Orbitrap Elite higher-energy collision-induced dissociation spectra recorded with a 96 ms transient enabling comparable dynamic range, precision, and accuracy of quantification as 1 Da spaced reporter ions. The increased multiplexing rate enabled determination of inhibitor potencies in chemoproteomic kinase assays covering a wider range of compound concentrations in a single experiment, compared to conventional 6-plex TMT-based assays

    High-Resolution Enabled TMT 8‑plexing

    No full text
    Isobaric mass tag-based quantitative proteomics strategies such as iTRAQ and TMT utilize reporter ions in the low-mass range of tandem MS spectra for relative quantification. The number of samples that can be compared in a single experiment (multiplexing) is limited by the number of different reporter ions that can be generated by differential stable isotope incorporation (<sup>15</sup>N, <sup>13</sup>C) across the reporter and the mass balancing parts of the reagents. Here, we demonstrate that a higher multiplexing rate can be achieved by utilizing the 6 mDa mass difference between <sup>15</sup>N- and <sup>13</sup>C-containing reporter fragments, in combination with high-resolution mass spectrometry. Two variants of the TMT127 and TMT129 reagents are available; these are distinguished by the position and the nature of the incorporated stable isotope in the reporter portions of the labels (TMT127L, <sup>12</sup>C<sub>8</sub>H<sub>16</sub><sup>15</sup>N<sub>1</sub><sup>+</sup>; TMT127H, <sup>12</sup>C<sub>7</sub><sup>13</sup>C<sub>1</sub>H<sub>16</sub><sup>14</sup>N<sub>1</sub><sup>+</sup>; TMT129L, <sup>12</sup>C<sub>6</sub><sup>13</sup>C<sub>2</sub>H<sub>16</sub><sup>15</sup>N<sub>1</sub><sup>+</sup>; and TMT129H, <sup>12</sup>C<sub>5</sub><sup>13</sup>C<sub>3</sub>H<sub>16</sub><sup>14</sup>N<sub>1</sub><sup>+</sup>). We demonstrate that these variants can be baseline-resolved in Orbitrap Elite higher-energy collision-induced dissociation spectra recorded with a 96 ms transient enabling comparable dynamic range, precision, and accuracy of quantification as 1 Da spaced reporter ions. The increased multiplexing rate enabled determination of inhibitor potencies in chemoproteomic kinase assays covering a wider range of compound concentrations in a single experiment, compared to conventional 6-plex TMT-based assays

    High-Resolution Enabled TMT 8‑plexing

    No full text
    Isobaric mass tag-based quantitative proteomics strategies such as iTRAQ and TMT utilize reporter ions in the low-mass range of tandem MS spectra for relative quantification. The number of samples that can be compared in a single experiment (multiplexing) is limited by the number of different reporter ions that can be generated by differential stable isotope incorporation (<sup>15</sup>N, <sup>13</sup>C) across the reporter and the mass balancing parts of the reagents. Here, we demonstrate that a higher multiplexing rate can be achieved by utilizing the 6 mDa mass difference between <sup>15</sup>N- and <sup>13</sup>C-containing reporter fragments, in combination with high-resolution mass spectrometry. Two variants of the TMT127 and TMT129 reagents are available; these are distinguished by the position and the nature of the incorporated stable isotope in the reporter portions of the labels (TMT127L, <sup>12</sup>C<sub>8</sub>H<sub>16</sub><sup>15</sup>N<sub>1</sub><sup>+</sup>; TMT127H, <sup>12</sup>C<sub>7</sub><sup>13</sup>C<sub>1</sub>H<sub>16</sub><sup>14</sup>N<sub>1</sub><sup>+</sup>; TMT129L, <sup>12</sup>C<sub>6</sub><sup>13</sup>C<sub>2</sub>H<sub>16</sub><sup>15</sup>N<sub>1</sub><sup>+</sup>; and TMT129H, <sup>12</sup>C<sub>5</sub><sup>13</sup>C<sub>3</sub>H<sub>16</sub><sup>14</sup>N<sub>1</sub><sup>+</sup>). We demonstrate that these variants can be baseline-resolved in Orbitrap Elite higher-energy collision-induced dissociation spectra recorded with a 96 ms transient enabling comparable dynamic range, precision, and accuracy of quantification as 1 Da spaced reporter ions. The increased multiplexing rate enabled determination of inhibitor potencies in chemoproteomic kinase assays covering a wider range of compound concentrations in a single experiment, compared to conventional 6-plex TMT-based assays

    High-Resolution Enabled TMT 8‑plexing

    No full text
    Isobaric mass tag-based quantitative proteomics strategies such as iTRAQ and TMT utilize reporter ions in the low-mass range of tandem MS spectra for relative quantification. The number of samples that can be compared in a single experiment (multiplexing) is limited by the number of different reporter ions that can be generated by differential stable isotope incorporation (<sup>15</sup>N, <sup>13</sup>C) across the reporter and the mass balancing parts of the reagents. Here, we demonstrate that a higher multiplexing rate can be achieved by utilizing the 6 mDa mass difference between <sup>15</sup>N- and <sup>13</sup>C-containing reporter fragments, in combination with high-resolution mass spectrometry. Two variants of the TMT127 and TMT129 reagents are available; these are distinguished by the position and the nature of the incorporated stable isotope in the reporter portions of the labels (TMT127L, <sup>12</sup>C<sub>8</sub>H<sub>16</sub><sup>15</sup>N<sub>1</sub><sup>+</sup>; TMT127H, <sup>12</sup>C<sub>7</sub><sup>13</sup>C<sub>1</sub>H<sub>16</sub><sup>14</sup>N<sub>1</sub><sup>+</sup>; TMT129L, <sup>12</sup>C<sub>6</sub><sup>13</sup>C<sub>2</sub>H<sub>16</sub><sup>15</sup>N<sub>1</sub><sup>+</sup>; and TMT129H, <sup>12</sup>C<sub>5</sub><sup>13</sup>C<sub>3</sub>H<sub>16</sub><sup>14</sup>N<sub>1</sub><sup>+</sup>). We demonstrate that these variants can be baseline-resolved in Orbitrap Elite higher-energy collision-induced dissociation spectra recorded with a 96 ms transient enabling comparable dynamic range, precision, and accuracy of quantification as 1 Da spaced reporter ions. The increased multiplexing rate enabled determination of inhibitor potencies in chemoproteomic kinase assays covering a wider range of compound concentrations in a single experiment, compared to conventional 6-plex TMT-based assays

    High-Resolution Enabled TMT 8‑plexing

    No full text
    Isobaric mass tag-based quantitative proteomics strategies such as iTRAQ and TMT utilize reporter ions in the low-mass range of tandem MS spectra for relative quantification. The number of samples that can be compared in a single experiment (multiplexing) is limited by the number of different reporter ions that can be generated by differential stable isotope incorporation (<sup>15</sup>N, <sup>13</sup>C) across the reporter and the mass balancing parts of the reagents. Here, we demonstrate that a higher multiplexing rate can be achieved by utilizing the 6 mDa mass difference between <sup>15</sup>N- and <sup>13</sup>C-containing reporter fragments, in combination with high-resolution mass spectrometry. Two variants of the TMT127 and TMT129 reagents are available; these are distinguished by the position and the nature of the incorporated stable isotope in the reporter portions of the labels (TMT127L, <sup>12</sup>C<sub>8</sub>H<sub>16</sub><sup>15</sup>N<sub>1</sub><sup>+</sup>; TMT127H, <sup>12</sup>C<sub>7</sub><sup>13</sup>C<sub>1</sub>H<sub>16</sub><sup>14</sup>N<sub>1</sub><sup>+</sup>; TMT129L, <sup>12</sup>C<sub>6</sub><sup>13</sup>C<sub>2</sub>H<sub>16</sub><sup>15</sup>N<sub>1</sub><sup>+</sup>; and TMT129H, <sup>12</sup>C<sub>5</sub><sup>13</sup>C<sub>3</sub>H<sub>16</sub><sup>14</sup>N<sub>1</sub><sup>+</sup>). We demonstrate that these variants can be baseline-resolved in Orbitrap Elite higher-energy collision-induced dissociation spectra recorded with a 96 ms transient enabling comparable dynamic range, precision, and accuracy of quantification as 1 Da spaced reporter ions. The increased multiplexing rate enabled determination of inhibitor potencies in chemoproteomic kinase assays covering a wider range of compound concentrations in a single experiment, compared to conventional 6-plex TMT-based assays

    Ion Coalescence of Neutron Encoded TMT 10-Plex Reporter Ions

    No full text
    Isobaric mass tag-based quantitative proteomics strategies such as iTRAQ and TMT utilize reporter ions in the low mass range of tandem MS spectra for relative quantification. The recent extension of TMT multiplexing to 10 conditions has been enabled by utilizing neutron encoded tags with reporter ion <i>m</i>/<i>z</i> differences of 6 mDa. The baseline resolution of these closely spaced tags is possible due to the high resolving power of current day mass spectrometers. In this work we evaluated the performance of the TMT10 isobaric mass tags on the Q Exactive Orbitrap mass spectrometers for the first time and demonstrated comparable quantification accuracy and precision to what can be achieved on the Orbitrap Elite mass spectrometers. However, we discovered, upon analysis of complex proteomics samples on the Q Exactive Orbitrap mass spectrometers, that the proximate TMT10 reporter ion pairs become prone to coalescence. The fusion of the different reporter ion signals into a single measurable entity has a detrimental effect on peptide and protein quantification. We established that the main reason for coalescence is the commonly accepted maximum ion target for MS2 spectra of 1e6 on the Q Exactive instruments. The coalescence artifact was completely removed by lowering the maximum ion target for MS2 spectra from 1e6 to 2e5 without any losses in identification depth or quantification quality of proteins
    corecore