13 research outputs found

    Estudo comparativo da microdureza de materiais resinosos indiretos

    Get PDF
    The purpose of this study was to compare the microhardness of four indirect composite resins. Forty cylindrical samples were prepared according to the manufacturers recommendations using a Teflon mold. Ten specimens were produced from each tested material, constituting four groups (n=10) as follows: G1 - Artglass; G2 - Sinfony; G3 - Solidex; G4 - Targis. Microhardness was determined by the Vickers indentation technique with a load of 300g for 10 seconds. Four indentations were made on each sample, determining the mean microhardness values for each specimen. Descriptive statistics data for the experimental conditions were: G1 - Artglass (mean ±standard deviation: 55.26 ± 1.15HVN; median: 52.6); G2 - Sinfony (31.22 ± 0.65HVN; 31.30); G3 - Solidex (52.25 ± 1.55HVN; 52.60); G4 - Targis (72.14 ± 2.82HVN; 73.30). An exploratory data analysis was performed to determine the most appropriate statistical test through: (I) Levene's for homogeneity of variances; (II) ANOVA on ranks (Kruskal-Wallis); (III) Dunn's multiple comparison test (0.05). Targis presented the highest microhardness values while Sinfony presented the lowest. Artglass and Solidex were found as intermediate materials. These results indicate that distinct mechanical properties may be observed at specific materials. The composition of each material as well as variations on polymerization methods are possibly responsibles for the difference found in microhardness. Therefore, indirect composite resin materials that guarantee both good esthetics and adequate mechanical properties may be considered as substitutes of natural teeth.O objetivo deste estudo foi comparar a microdureza de 4 resinas compostas indiretas. Quarenta amostras cilĂ­ndricas foram obtidas com o auxĂ­lio de uma matriz de teflon, seguindo-se as recomendações dos fabricantes. Foram obtidas 10 amostras para cada material testado, contituindo-se 4 grupos (n=10) como se segue: G1-Artglass; G2-Sinfony; G3-Solidex; G4-Targis. A microdureza foi determinada pela tĂ©cnica da indentação Vickers com uma carga de 300g por 10 segundos. Quatro indentações foram realizadas em cada amostra, obtendo-se um valor mĂ©dio. Os dados da análise estatĂ­stica descritiva para cada condição experimental foram: G1-Artglass (mĂ©dia ± desvio padrĂŁo:55,26 ± 1,15HVN; mediana: 52,6); G2- Sinfony (31,22 ± 0,65HVN; 31,30); G3- Solidex (52,25 ± 1,55HVN; 52,60); G4- Targis (72,14 ± 2,82HVN; 73,30). Uma análise exploratĂłria dos dados foi realizada para determinar o teste estatĂ­stico mais apropriado: (I) Teste de Levene para variâncias homogĂŞneas; (II) Teste de ANOVA (Kruskal-Wallis); (III) Teste de comparação mĂşltipla de Dunn. O Targis apresentou os maiores valores de microdureza, enquanto que o Sinfony apresentou os menores valores. O Artglass e o Solidex se comportaram como materiais intermediários. Estes resultados indicaram que propriedades mecânicas distintas podem ser observadas nos materiais. A composição de cada material, bem como as variações nos mĂ©todos de polimerização sĂŁo possivelmente responsáveis pelas diferenças observadas na microdureza. Portanto, materiais resinosos indiretos que garantam estĂ©tica e propriedades mecânicas satisfatĂłrias podem ser considerados como substitutos dos dentes naturais

    Avaliação da tenacidade à fratura de diferentes sistemas cerâmicos

    Get PDF
    Although ceramics present high compressive strength, they are brittle materials due to their low tensile strength so they have lower capacity to absorb shocks. This study evaluated the fracture toughness of different ceramic systems, which refers to the ability of a friable material to absorb defformation energy. Three ceramic systems were investigated. Ten cylindrical samples (5,0mm x 3,0mm), were obtained from each ceramic material as follows: G1- 10 samples of Vitadur Alpha (Vita-Zahnfabrik); G2- 10 samples of IPS Empress2 (Ivoclar-Vivadent); G3- 10 samples of In-Ceram Alumina (Vita-Zahnfabrik). Fracture toughness values were collected upon indentation tests that were performed under a heavy load. A microhardness tester (Digital Microhardness Tester FM) utilized a 500gf load cell during 10seconds to perform four impressions on each sample. Statistically significant results were observed (ANOVA and Kruskal-Wallis tests). In-Ceram Alumina presented the highest median toughness values (2,96N/m3/2), followed by Vitadur Alpha (2,08N/m3/2) and IPS Empress2 (1,05N/m3/2). It may be concluded that different ceramic systems present distinct fracture toughness values, thus In-Ceram is capable of absorbing superior stress when compared to Vitadur Alpha and IPS Empress2.Embora as cerâmicas possuam alta resistência à compressão, apresentam friabilidade devido à sua baixa resistência à tração e, desta forma, possuem menor capacidade de absorver impactos. Este trabalho avaliou a tenacidade à fratura de diferentes sistemas cerâmicos, que refere-se à medida da habilidade de absorção da energia de deformação de um material friável. Foram confeccionados 30 corpos-de-prova em forma de discos (5mmx3mm) utilizando-se três diferentes materiais cerâmicos, os quais foram divididos em 3 grupos: G1-10 amostras confeccionadas com a cerâmica Vitadur Alpha (Vita-Zahnfabrik); G2-10 amostras confeccionadas com a cerâmica IPS Empress 2 (Ivoclar-Vivadent) e G3-10 amostras confeccionadas com a cerâmica In-Ceram Alumina (Vita-Zahnfabrik). Para a obtenção dos valores de tenacidade foi utilizada a técnica da indentação que se baseia na série de fissuras que se formam sob uma carga pesada. Foram realizadas 4 impressões por amostra, utilizado um microdurômetro (Digital Microhardness Tester FM) com uma carga de 500gf, durante 10 segundos. A análise estatística dos dados (Testes ANOVA de Kruskal-Wallis e Dunn), indica que a cerâmica In-Ceram Alumina apresentou valor mediano (2,96N/m3/2), estatisticamente diferente do apresentado pela IPS Empress 2 (1,05N/m3/2), enquanto que a cerâmica Vitadur Alpha apresentou valores intermediários (2,08N/m3/2), sem diferenças estatísticas dos outros dois materiais. Conclui-se que as cerâmicas apresentam diferentes desempenhos de tenacidade à fratura, sendo a In-Ceram capaz de absorver maior energia comparada a Vitadur Alpha e ao IPS Empress2

    Avaliação da tenacidade à fratura de diferentes sistemas cerâmicos

    Get PDF
    Although ceramics present high compressive strength, they are brittle materials due to their low tensile strength so they have lower capacity to absorb shocks. This study evaluated the fracture toughness of different ceramic systems, which refers to the ability of a friable material to absorb defformation energy. Three ceramic systems were investigated. Ten cylindrical samples (5,0mm x 3,0mm), were obtained from each ceramic material as follows: G1- 10 samples of Vitadur Alpha (Vita-Zahnfabrik); G2- 10 samples of IPS Empress2 (Ivoclar-Vivadent); G3- 10 samples of In-Ceram Alumina (Vita-Zahnfabrik). Fracture toughness values were collected upon indentation tests that were performed under a heavy load. A microhardness tester (Digital Microhardness Tester FM) utilized a 500gf load cell during 10seconds to perform four impressions on each sample. Statistically significant results were observed (ANOVA and Kruskal-Wallis tests). In-Ceram Alumina presented the highest median toughness values (2,96N/m3/2), followed by Vitadur Alpha (2,08N/m3/2) and IPS Empress2 (1,05N/m3/2). It may be concluded that different ceramic systems present distinct fracture toughness values, thus In-Ceram is capable of absorbing superior stress when compared to Vitadur Alpha and IPS Empress2

    A comparison of microhardness of indirect composite restorative materials

    No full text
    The purpose of this study was to compare the microhardness of four indirect composite resins. Forty cylindrical samples were prepared according to the manufacturerÂ’s recommendations using a Teflon mold. Ten specimens were produced from each tested material, constituting four groups (n=10) as follows: G1 - Artglass; G2 - Sinfony; G3 - Solidex; G4 - Targis. Microhardness was determined by the Vickers indentation technique with a load of 300g for 10 seconds. Four indentations were made on each sample, determining the mean microhardness values for each specimen. Descriptive statistics data for the experimental conditions were: G1 - Artglass (mean ±standard deviation: 55.26 ± 1.15HVN; median: 52.6); G2 - Sinfony (31.22 ± 0.65HVN; 31.30); G3 - Solidex (52.25 ± 1.55HVN; 52.60); G4 - Targis (72.14 ± 2.82HVN; 73.30). An exploratory data analysis was performed to determine the most appropriate statistical test through: (I) Levene's for homogeneity of variances; (II) ANOVA on ranks (Kruskal-Wallis); (III) Dunn's multiple comparison test (0.05). Targis presented the highest microhardness values while Sinfony presented the lowest. Artglass and Solidex were found as intermediate materials. These results indicate that distinct mechanical properties may be observed at specific materials. The composition of each material as well as variations on polymerization methods are possibly responsibles for the difference found in microhardness. Therefore, indirect composite resin materials that guarantee both good esthetics and adequate mechanical properties may be considered as substitutes of natural teeth

    Micro-morphological changes prior to adhesive bonding: high-alumina and glassy-matrix ceramics

    No full text
    The aim of this study was to qualitatively demonstrate surface micro-morphological changes after the employment of different surface conditioning methods on high-alumina and glassy-matrix dental ceramics. Three disc-shaped high-alumina specimens (In-Ceram Alumina, INC) and 4 glassy-matrix ceramic specimens (Vitadur Alpha, V) (diameter: 5 mm and height: 5 mm) were manufactured. INC specimens were submitted to 3 different surface conditioning methods: INC1 - Polishing with silicon carbide papers (SiC); INC2 - Chairside air-borne particle abrasion (50 µm Al2O3); INC3 - Chairside silica coating (CoJet; 30 µm SiOx). Vitadur Alpha (V) specimens were subjected to 4 different surface conditioning methods: V1 - Polishing with SiC papers; V2 - HF acid etching; V3 - Chairside air-borne particle abrasion (50 µm Al2O3); V4 - Chairside silica coating (30 µm SiOx). Following completion of the surface conditioning methods, the specimens were analyzed using SEM. After polishing with SiC, the surfaces of V specimens remained relatively smooth while those of INC exhibited topographic irregularities. Chairside air-abrasion with either aluminum oxide or silica particles produced retentive patterns on both INC and V specimens, with smoother patterns observed after silica coating. V specimens etched with HF presented a highly porous surface. Chairside tribochemical silica coating resulted in smoother surfaces with particles embedded on the surface even after air-blasting. Surface conditioning using air-borne particle abrasion with either 50 µm alumina or 30 µm silica particles exhibited qualitatively comparable rough surfaces for both INC and V. HF acid gel created the most micro-retentive surface for the glassy-matrix ceramic tested

    Survival Rate and Deformation of External Hexagon Implants with One-Piece Zirconia Crowns

    No full text
    This study aimed to evaluate the survival rates of several external hexagon implants directly connected to zirconia crowns after thermomechanical fatigue. The deformation of the hexagons and the integrity of zirconia crowns were also evaluated. A monolithic zirconia crown (Y-TZP) and four different external hexagon dental implants (n = 10, N = 40) were mounted together and embedded in polyurethane. The specimens were subjected to thermomechanical cycling for 2.5 Ă— 106 cycles, at 3.0 Hz frequency, at 200 N loading. The interface of the implant/zirconia crown system, zirconia crowns integrity before and after cycling, and the implant hexagon surface were evaluated under stereomicroscopy and SEM. A nanohardness analysis was performed to verify the hardness of zirconia and implants. Statistical analysis was performed using the Kaplan-Meier test, Multi-Sample Survival Tests, Logrank Test, (p = 0.05). The data did not show significant differences in the survival rates of different implant groups. However, some crowns presented fractures (16.67%) and the external hexagon region of the implants presented plastic deformations (100%). During chewing simulation, the interface between titanium implant and zirconia abutment can promote plastic deformation in the metal and surface defects in the ceramic. In addition, the types of interface defects can be affected by the external hexagon design
    corecore