55 research outputs found

    Multicentre quantitative Ga-68 PET/CT performance harmonisation

    Get PDF
    Purpose Performance standards for quantitative F-18-FDG PET/CT studies are provided by the EANM Research Ltd. (EARL) to enable comparability of quantitative PET in multicentre studies. Yet, such specifications are not available for Ga-68. Therefore, our aim was to evaluate Ga-68-PET/CT quantification variability in a multicentre setting. Methods A survey across Dutch hospitals was performed to evaluate differences in clinical Ga-68 PET/CT study protocols. Ga-68 and F-18 phantom acquisitions were performed by 8 centres with 13 different PET/CT systems according to EARL protocol. The cylindrical phantom and NEMA image quality (IQ) phantom were used to assess image noise and to identify recovery coefficients (RCs) for quantitative analysis. Both phantoms were used to evaluate cross-calibration between the PET/CT system and local dose calibrator. Results The survey across Dutch hospitals showed a large variation in clinical Ga-68 PET/CT acquisition and reconstruction protocols. Ga-68 PET/CT image noise was below 10%. Cross-calibration was within 10% deviation, except for one system to overestimate F-18 and two systems to underestimate the Ga-68 activity concentration. RC-curves for F-18 and Ga-68 were within and on the lower limit of current EARL standards, respectively. After correction for local Ga-68/F-18 cross-calibration, mean Ga-68 performance was 5% below mean EARL performance specifications. Conclusions Ga-68 PET/CT quantification performs on the lower limits of the current EARL RC standards for F-18. Correction for local Ga-68/F-18 cross-calibration mismatch is advised, while maintaining the EARL reconstruction protocol thereby avoiding multiple EARL protocols

    Clinical impact of PSMA PET/CT in primary prostate cancer compared to conventional nodal and distant staging: a retrospective single center study

    Get PDF
    BACKGROUND: To evaluate the impact of Gallium-68 [68Ga] labeled prostate specific membrane antigen (PSMA) positron emission tomography (PET)/X-ray computed tomography (CT) compared with conventional imaging on staging and clinical management of men evaluated for primary prostate cancer (PCa). METHODS: Men with newly diagnosed biopsy-proven PCa who had been staged with a conventional staging protocol including bone scintigraphy (BS) and additionally underwent [68Ga]PSMA PET/CT, were evaluated retrospectively. Imaging findings from BS, magnetic resonance imaging (MRI) and/or CT were categorized regarding locoregional nodal (N) and distant metastasis (M) status as negative, positive or equivocal before and after addition of the information of PET/CT. Also, the imaging-based level of confidence (LoC) in correct assessment of N and M status was scored. Impact of PET/CT on clinical management was evaluated by the percentage of treatment category changes after PET/CT as determined in the multidisciplinary tumour board. RESULTS: Sixty-four men with intermediate and high-risk PCa were evaluated. With additional information of PET/CT, N status was upstaged in 23%, and downstaged in 9%. M status was upstaged in 13%, and downstaged in 23%. A net increase in LoC of 20% was noted, mainly regarding M status. Treatment category changed from palliative to curative in 9%, and from curative to palliative in 3%. An undecided treatment plan changed to curative in 14%, as well as to palliative in another 9%. In total, a 36% treatment category change was noted. High negative predictive value of PET/CT for M status was indicated by 27 patients that underwent robot-assisted radical prostatectomy and reached postoperative biochemical disease-free status or had a likely other site of disease recurrence. CONCLUSIONS: PSMA PET/CT can cause considerable changes in N and M staging, as well as in management compared to conventional staging. Findings of this study support the replacement of BS and CT by PSMA PET/CT in staging primary PCa

    The consequences of a new software package for the quantification of gated-SPECT myocardial perfusion studies

    Get PDF
    Semiquantitative analysis of myocardial perfusion scintigraphy (MPS) has reduced inter- and intraobserver variability, and enables researchers to compare parameters in the same patient over time, or between groups of patients. There are several software packages available that are designed to process MPS data and quantify parameters. In this study the performances of two systems, quantitative gated SPECT (QGS) and 4D-MSPECT, in the processing of clinical patient data and phantom data were compared. The clinical MPS data of 148 consecutive patients were analysed using QGS and 4D-MSPECT to determine the end-diastolic volume, end-systolic volume and left ventricular ejection fraction. Patients were divided into groups based on gender, body mass index, heart size, stressor type and defect type. The AGATE dynamic heart phantom was used to provide reference values for the left ventricular ejection fraction. Although the correlations were excellent (correlation coefficients 0.886 to 0.980) for all parameters, significant differences (p < 0.001) were found between the systems. Bland-Altman plots indicated that 4D-MSPECT provided overall higher values of all parameters than QGS. These differences between the systems were not significant in patients with a small heart (end-diastolic volume < 70 ml). Other clinical factors had no direct influence on the relationship. Additionally, the phantom data indicated good linear responses of both systems. The discrepancies between these software packages were clinically relevant, and influenced by heart size. The possibility of such discrepancies should be taken into account when a new quantitative software system is introduced, or when multiple software systems are used in the same institution.Vascular Biology and Interventio

    Limited effects of growth hormone replacement in patients with GH deficiency during long-term cure of acromegaly

    Get PDF
    The aim of this study was to assess the effects of replacement with recombinant human growth hormone (rhGH) in patients with GH deficiency (GHD) after treatment of acromegaly. Intervention study. Sixteen patients (8 men, age 56Β years), treated for acromegaly by surgery and radiotherapy, with an insufficient GH response to insulin-induced hypoglycaemia, were treated with 1Β year of rhGH replacement. Study parameters were assessed at baseline and after 1Β year of rhGH replacement. Study parameters were cardiac function, body composition, bone mineral density (BMD), fasting lipids, glucose, bone turnover markers, and Quality of Life (QoL). During rhGH replacement IGF-I concentrations increased from βˆ’0.4Β Β±Β 0.7 to 1.0Β Β±Β 1.5 SD (PΒ =Β 0.001), with a mean daily dose of 0.2Β Β±Β 0.1Β mg in men and 0.3Β Β±Β 0.2Β mg in women. Nonetheless, rhGH replacement did not alter cardiac function, lipid and glucose concentrations, body composition or QoL. Bone turnover markers (PINP and Ξ² crosslaps) levels increased (PΒ =Β 0.005 and PΒ =Β 0.021, respectively), paralleled by a small, but significant decrease in BMD of the hip. The beneficial effects of rhGH replacement in patients with GHD during cure from acromegaly are limited in this study

    Limitations of Tc99m-MIBI-SPECT Imaging Scans in Persistent Primary Hyperparathyroidism

    Get PDF
    In primary hyperparathyroidism (PHPT) the predictive value of technetium 99m sestamibi single emission computed tomography (Tc99m-MIBI-SPECT) for localizing pathological parathyroid glands before a first parathyroidectomy (PTx) is 83-100%. Data are scarce in patients undergoing reoperative parathyroidectomy for persistent hyperparathyroidism. The aim of the present study was to determine the value of Tc99m-MIBI-SPECT in localizing residual hyperactive parathyroid tissue in patients with persistent primary hyperparathyroidism (PHPT) after initial excision of one or more pathological glands. We retrospectively evaluated the localizing accuracy of Tc99m-MIBI-SPECT scans in 19 consecutive patients with persistent PHPT who had a scan before reoperative parathyroidectomy. We used as controls 23 patients with sporadic PHPT who had a scan before initial surgery. In patients with persistent PHPT, Tc99m-MIBI-SPECT accurately localized a pathological parathyroid gland in 33% of cases before reoperative parathyroidectomy, compared to 61% before first PTx for sporadic PHPT. The Tc99m-MIBI-SPECT scan accurately localized intra-thyroidal glands in 2 of 7 cases and a mediastinal gland in 1 of 3 cases either before initial or reoperative parathyroidectomy. Our data suggest that the accuracy of Tc99m-MIBI-SPECT in localizing residual hyperactive glands is significantly lower before reoperative parathyroidectomy for persistent PHPT than before initial surgery for sporadic PHPT. These findings should be taken in consideration in the preoperative workup of patients with persistent primary hyperparathyroidis

    Cardiac autonomic neuropathy in patients with diabetes and no symptoms of coronary artery disease: comparison of 123I-metaiodobenzylguanidine myocardial scintigraphy and heart rate variability

    Get PDF
    PURPOSE The purpose of this study was to evaluate the prevalence of cardiac autonomic neuropathy (CAN) in a cohort of patients with type 2 diabetes, truly asymptomatic for coronary artery disease (CAD), using heart rate variability (HRV) and (123)I-metaiodobenzylguanidine ((123)I-mIBG) myocardial scintigraphy. METHODS The study group comprised 88 patients with type 2 diabetes prospectively recruited from an outpatient diabetes clinic. In all patients myocardial perfusion scintigraphy, CAN by HRV and (123)I-mIBG myocardial scintigraphy were performed. Two or more abnormal tests were defined as CAN-positive (ECG-based CAN) and one or fewer as CAN-negative. CAN assessed by (123)I-mIBG scintigraphy was defined as abnormal if the heart-to-mediastinum ratio was 25%, or the total defect score was >13. RESULTS The prevalence of CAN in patients asymptomatic for CAD with type 2 diabetes and normal myocardial perfusion assessed by HRV and (123)I-mIBG scintigraphy was respectively, 27% and 58%. Furthermore, in almost half of patients with normal HRV, (123)I-mIBG scintigraphy showed CAN. CONCLUSION The current study revealed a high prevalence of CAN in patients with type 2 diabetes. Secondly, disagreement between HRV and (123)I-mIBG scintigraphy for the assessment of CAN was observed.Cardiovascular Aspects of Radiolog
    • …
    corecore