11 research outputs found

    Phase diagram for a Bose-Einstein condensate moving in an optical lattice

    Full text link
    The stability of superfluid currents in a system of ultracold bosons was studied using a moving optical lattice. Superfluid currents in a very weak lattice become unstable when their momentum exceeds 0.5 recoil momentum. Superfluidity vanishes already for zero momentum as the lattice deep reaches the Mott insulator(MI) phase transition. We study the phase diagram for the disappearance of superfluidity as a function of momentum and lattice depth between these two limits. Our phase boundary extrapolates to the critical lattice depth for the superfluid-to-MI transition with 2% precision. When a one-dimensional gas was loaded into a moving optical lattice a sudden broadening of the transition between stable and unstable phases was observed.Comment: 4 figure

    Observation of cold Rb

    No full text

    Observation of Climacteric-Like Behavior of Citrus Leaves Using Fluorescence Spectroscopy

    No full text
    Observation of climacteric-like behavior in citrus leaves depends on the detection of ethylene. However, such detection requires a gas chromatographer and complex sample preparation procedures. In this work, fluorescence spectroscopy was investigated as a diagnostic technique for climacteric-like behavior in citrus leaves. Our results indicate that the chlorophyll fluorescence presents a time evolution consistent with the ethylene evolution. Therefore, fluorescence spectroscopy may be used to observe the climacteric-like behavior in citrus leaves

    Detection of mechanical and disease stresses in citrus plants by fluorescence spectroscopy

    No full text
    We have investigated the detection of mechanical and disease stresses in citrus plants (Citrus limonia [L.] Osbeck) using laser-induced fluorescence spectroscopy. Due to its economic importance we have chosen to investigate the citrus canker disease, which is caused by the Xanthomonas axonopodis pv. citri bacteria. Mechanical stress was also studied because it plays an important role in the plant's infection by such bacteria. A laser-induced fluorescence spectroscopy system, composed of a spectrometer and a 532 nm 10 mW excitation laser was used to perform fluorescence spectroscopy. The ratio of two chlorophyll fluorescence bands allows us to detect and discriminate between mechanical and disease stresses. This ability to discriminate may have an important application in the field to detect citrus canker infected trees. (c) 2008 Optical Society of America

    Role of multilevel Rydberg interactions in electric-field-tuned Förster resonances

    Get PDF
    In this work, we investigate the dc electric-field dependence of two Forster resonant processes in ultracold ¨ 85Rb, 37D5/2 + 37D5/2 → 35L(L = O,Q) + 39P3/2, as a function of the atomic density. At low densities, the 39P3/2 yield as a function of electric field exhibits resonances. With increasing density, the linewidths increase until the peaks merge. Even under these extreme conditions, where the Forster resonance processes show little ¨ electric-field dependence, the 39P3/2 population depends quadratically on the total Rydberg atom population, suggesting that a two-body interaction is the dominant process. In order to explain our results, we implement a theoretical model which takes into account the multilevel character of the interactions and Rydberg atom blockade process using only atom pair interactions. The comparison between the experimental data and the model is very good, suggesting that the Forster resonant processes are dominated by two-body interactions up to ¨ atomic densities of 3.0 × 10^12 cm^−3

    Impact of COVID-19 Pandemic on Cardiovascular Testing in Asia: The IAEA INCAPS-COVID Study

    No full text
    Background: The coronavirus disease-2019 (COVID-19) pandemic significantly affected management of cardiovascular disease around the world. The effect of the pandemic on volume of cardiovascular diagnostic procedures is not known. Objectives: This study sought to evaluate the effects of the early phase of the COVID-19 pandemic on cardiovascular diagnostic procedures and safety practices in Asia. Methods: The International Atomic Energy Agency conducted a worldwide survey to assess changes in cardiovascular procedure volume and safety practices caused by COVID-19. Testing volumes were reported for March 2020 and April 2020 and were compared to those from March 2019. Data from 180 centers across 33 Asian countries were grouped into 4 subregions for comparison. Results: Procedure volumes decreased by 47% from March 2019 to March 2020, showing recovery from March 2020 to April 2020 in Eastern Asia, particularly in China. The majority of centers cancelled outpatient activities and increased time per study. Practice changes included implementing physical distancing and restricting visitors. Although COVID testing was not commonly performed, it was conducted in one-third of facilities in Eastern Asia. The most severe reductions in procedure volumes were observed in lower-income countries, where volumes decreased 81% from March 2019 to April 2020. Conclusions: The COVID-19 pandemic in Asia caused significant reductions in cardiovascular diagnostic procedures, particularly in low-income countries. Further studies on effects of COVID-19 on cardiovascular outcomes and changes in care delivery are warranted

    Impact of COVID-19 on Cardiovascular Testing in the United States Versus the Rest of the World

    No full text
    Objectives: This study sought to quantify and compare the decline in volumes of cardiovascular procedures between the United States and non-U.S. institutions during the early phase of the coronavirus disease-2019 (COVID-19) pandemic. Background: The COVID-19 pandemic has disrupted the care of many non-COVID-19 illnesses. Reductions in diagnostic cardiovascular testing around the world have led to concerns over the implications of reduced testing for cardiovascular disease (CVD) morbidity and mortality. Methods: Data were submitted to the INCAPS-COVID (International Atomic Energy Agency Non-Invasive Cardiology Protocols Study of COVID-19), a multinational registry comprising 909 institutions in 108 countries (including 155 facilities in 40 U.S. states), assessing the impact of the COVID-19 pandemic on volumes of diagnostic cardiovascular procedures. Data were obtained for April 2020 and compared with volumes of baseline procedures from March 2019. We compared laboratory characteristics, practices, and procedure volumes between U.S. and non-U.S. facilities and between U.S. geographic regions and identified factors associated with volume reduction in the United States. Results: Reductions in the volumes of procedures in the United States were similar to those in non-U.S. facilities (68% vs. 63%, respectively; p = 0.237), although U.S. facilities reported greater reductions in invasive coronary angiography (69% vs. 53%, respectively; p < 0.001). Significantly more U.S. facilities reported increased use of telehealth and patient screening measures than non-U.S. facilities, such as temperature checks, symptom screenings, and COVID-19 testing. Reductions in volumes of procedures differed between U.S. regions, with larger declines observed in the Northeast (76%) and Midwest (74%) than in the South (62%) and West (44%). Prevalence of COVID-19, staff redeployments, outpatient centers, and urban centers were associated with greater reductions in volume in U.S. facilities in a multivariable analysis. Conclusions: We observed marked reductions in U.S. cardiovascular testing in the early phase of the pandemic and significant variability between U.S. regions. The association between reductions of volumes and COVID-19 prevalence in the United States highlighted the need for proactive efforts to maintain access to cardiovascular testing in areas most affected by outbreaks of COVID-19 infection
    corecore