3 research outputs found

    Relationship between positive end-expiratory pressure levels, central venous pressure, systemic inflammation and acute renal failure in critically ill ventilated COVID-19 patients: a monocenter retrospective study in France

    Get PDF
    Background The role of positive pressure ventilation, central venous pressure (CVP) and inflammation on the occurrence of acute kidney injury (AKI) have been poorly described in mechanically ventilated patient secondary to coronavirus disease 2019 (COVID-19). Methods This was a monocenter retrospective cohort study of consecutive ventilated COVID-19 patients admitted in a French surgical intensive care unit between March 2020 and July 2020. Worsening renal function (WRF) was defined as development of a new AKI or a persistent AKI during the 5 days after mechanical ventilation initiation. We studied the association between WRF and ventilatory parameters including positive end-expiratory pressure (PEEP), CVP, and leukocytes count. Results Fifty-seven patients were included, 12 (21%) presented WRF. Daily PEEP, 5 days mean PEEP and daily CVP values were not associated with occurrence of WRF. 5 days mean CVP was higher in the WRF group compared to patients without WRF (median [IQR], 12 mm Hg [11-13] vs. 10 mm Hg [9–12]; P=0.03). Multivariate models with adjustment on leukocytes and Simplified Acute Physiology Score (SAPS) II confirmed the association between CVP value and risk of WRF (odd ratio, 1.97; 95% confidence interval, 1.12–4.33). Leukocytes count was also associated with occurrence of WRF in the WRF group (14 G/L [11–18]) and the no-WRF group (9 G/L [8–11]) (P=0.002). Conclusions In mechanically ventilated COVID-19 patients, PEEP levels did not appear to influence occurrence of WRF. High CVP levels and leukocytes count are associated with risk of WRF

    Impact of impaired cerebral blood flow autoregulation on electroencephalogram signals in adults undergoing propofol anaesthesia: a pilot study

    No full text
    International audienceBackground: Cerebral autoregulation actively maintains cerebral blood flow over a range of MAPs. During general anaesthesia, this mechanism may not compensate for reductions in MAP leading to brain hypoperfusion. Cerebral autoregulation can be assessed using the mean flow index derived from Doppler measurements of average blood velocity in the middle cerebral artery, but this is impractical for routine monitoring within the operating room. Here, we investigate the possibility of using the EEG as a proxy measure for a loss of cerebral autoregulation, determined by the mean flow index. Methods: Thirty-six patients (57.5 [44.25; 66.5] yr; 38.9% women, non-emergency neuroradiology surgery) anaesthetised using propofol were prospectively studied. Continuous recordings of MAP, average blood velocity in the middle cerebral artery, EEG, and regional cerebral oxygen saturation were made. Poor cerebral autoregulation was defined as a mean flow index greater than 0.3. Results: Eighteen patients had preserved cerebral autoregulation, and 18 had altered cerebral autoregulation. The two groups had similar ages, MAPs, and average blood velocities in the middle cerebral artery. Patients with altered cerebral autoregulation exhibited a significantly slower alpha peak frequency (9

    Exploiting Task Constraints for Self-Calibrated Brain-Machine Interface Control Using Error-Related Potentials

    Get PDF
    International audienceThis paper presents a new approach for self-calibration BCI for reaching tasks using error-related potentials. The proposed method exploits task constraints to simultaneously calibrate the decoder and control the device, by using a robust likelihood function and an ad-hoc planner to cope with the large uncertainty resulting from the unknown task and decoder. The method has been evaluated in closed-loop online experiments with 8 users using a previously proposed BCI protocol for reaching tasks over a grid. The results show that it is possible to have a usable BCI control from the beginning of the experiment without any prior calibration. Furthermore, comparisons with simulations and previous results obtained using standard calibration hint that both the quality of recorded signals and the performance of the system were comparable to those obtained with a standard calibration approach
    corecore