24 research outputs found

    Spontaneous sealing of a type Ia endoleak after ovation stent graft implantation in a patient with on-label aortic neck anatomy

    Get PDF
    We report a case of an early type Ia endoleak after endovascular aneurysm repair (EVAR) of an abdominal aortic aneurysm by Ovation Stent Graft implantation and spontaneously resolved without further reintervention. The patient presents a conical aortic neck, but EVAR was performed within the instruction for use proposed by manufactory. At completion angiography, a low-flow type Ia endoleak was present and left untreated. Computed tomographic angiography performed on the third postoperative day showed infolding of the 2 sealing rings. The patient was dismissed without further treatment. At 3-month follow-up, the leak appeared spontaneously sealed with partial expansion of the 2 rings.We report a case of an early type Ia endoleak after endovascular aneurysm repair (EVAR) of an abdominal aortic aneurysm by Ovation Stent Graft implantation and spontaneously resolved without further reintervention. The patient presents a conical aortic neck, but EVAR was performed within the instruction for use proposed by manufactory. At completion angiography, a low-flow type Ia endoleak was present and left untreated. Computed tomographic angiography performed on the third postoperative day showed infolding of the 2 sealing rings. The patient was dismissed without further treatment. At 3-month follow-up, the leak appeared spontaneously sealed with partial expansion of the 2 rings

    Open conversion after aortic endograft infection. Caused by colistin-resistant, carbapenemase-producing Klebsiella pneumoniae

    Get PDF
    A 62-year-old man presented with fever, abdominal pain, and malaise 13 months after emergency endovascular aortic repair. Computed tomographic angiograms showed a periprosthetic fluid and gas collection, so infection was diagnosed. Open conversion was performed, involving endograft explantation and in situ aortic reconstruction. Cultures and the explanted prosthesis were positive for carbapenemase-producing Klebsiella pneumoniae, resistant to colistin. Because of the sparse data on endograft infections caused by this pathogen, we placed the patient on an empiric double-carbapenem regimen for 4 weeks. Symptomatic recovery occurred after 21 days. On the 30th day, we deployed a stent to treat a new pseudoaneurysm. Three years later, the patient had no signs of persistent or recurrent infection. We think that this is the first report of aortic endograft infection caused by colistin-resistant, carbapenemase-producing K. pneumoniae.A 62-year-old man presented with fever, abdominal pain, and malaise 13 months after emergency endovascular aortic repair. Computed tomographic angiograms showed a periprosthetic fluid and gas collection, so infection was diagnosed. Open conversion was performed, involving endograft explantation and in situ aortic reconstruction. Cultures and the explanted prosthesis were positive for carbapenemase-producing Klebsiella pneumoniae, resistant to colistin. Because of the sparse data on endograft infections caused by this pathogen, we placed the patient on an empiric double-carbapenem regimen for 4 weeks. Symptomatic recovery occurred after 21 days. On the 30th day, we deployed a stent to treat a new pseudoaneurysm. Three years later, the patient had no signs of persistent or recurrent infection. We think that this is the first report of aortic endograft infection caused by colistin-resistant, carbapenemase-producing K. pneumoniae

    Peri-procedural brain lesions prevention in CAS (3PCAS). Randomized trial comparing CGuardℱ stent vs. wallstent

    Get PDF
    Background: Aim of this study was to evaluate peri-procedural incidence of new diffusion-weighted-magneticresonance- imaging (DWMRI) brain lesions in CAS patients treated by carotid mesh stent (CGuardℱ) or closed-cell stent (Wallstentℱ). Methods: Consecutive patients with asymptomatic carotid stenosis ≄ 70% were submitted to preoperative DWMRI scan, to exclude the presence of preoperative silent cerebral lesions. Patients were randomized to CGuard orWallstent. DWMRI was performed immediately after the intervention and at 72-hour postoperatively. Moreover, pre and postoperative Mini-Mental-State-Examination Test (MMSE) and aMontreal-Cognitive-Assessment (MoCA) test were conducted, and S100ÎČ and NSE neurobiomarkers were measured at 5-time points (preoperatively, 2, 12, 24, and 48 h postoperatively). Results: From January 2015 to October 2016, sixty-one consecutive eligible patients were submitted to preoperative DWMRI scan. Three patients were excluded because of preoperative silent cerebral lesions. In 29 CGuard patients, 1 developed a minor stroke and 8 silent newlesionswere observed in the 72 h-DWMRI (31%): 4 lesions were ipsilateral, and 4 lesions were contra or bilateral. In 29 Wallstent patients, 7 clinically-silent new lesions were found in the 72 h-DWMRI (24.1%; p = 0.38). In 4 cases lesions were ipsilateral and in 3 cases contra or bilateral. S100B values doubled at 48 h in 24 patients, and among them 12 presented new DWMRI lesions. 48-h S100B increase was significantly related to 72-h DWMRI lesions (p= 0.012). Conclusions: In our experience both stents showed an acceptable rate of subclinical neurological events with no significant differences at 72-hour DWMRI between groups. Bilateral/contralateral lesions suggest that periprocedural neurological damage may have extra-carotid sources

    Abstracts from the 3rd International Genomic Medicine Conference (3rd IGMC 2015)

    Get PDF

    Pressure injury to the chest wall caused by vascular graft and endograft after thoracic and thoraco-abdominal aortic repair

    No full text
    Thoracic and thoraco-abdominal aortic repair remains a challenging issue in vascular surgery, and long-term complications are well described. We report 2 cases of octogenarians with unusual long-term complications after open and endovascular thoracic aortic repair of chest wall pressure injury from the vascular prosthesis. In the first case, a computed tomographic scan of an 80-year-old man showed a pressure injury of the chest wall and rib erosion caused by a Dacron graft. The second case was an 81-year-old woman who presented with external bleeding from the left posterior chest wall. A computed tomographic scan showed a type IA endoleak and chest wall damage with rib erosion and thoracic cutaneous fistulae from the endovascular graft. Both patients were treated by relining the endovascular graft; debriding the surgical fistula was done only in the second case. In our experience, endovascular repair is a good option to avoid a complete open surgical repair

    Silent stroke and cognitive decline in asymptomatic carotid stenosis revascularization

    No full text
    The aim of this study was to assess the relationship between serum levels of S100 beta and neuron-specific enolase (NSE), postoperative diffusion-weighted magnetic resonance imaging (DW-MRI) and Mini-Mental State Examination (MMSE) score in asymptomatic patients affected by >= 70% carotid stenosis submitted to carotid endarterectomy (CEA) or carotid artery stenting (CAS), and to compare MMSE scores and DW-MRI findings at follow-up evaluations. Between April 2008 and April 2009, 60 patients were submitted to carotid intervention. All patients underwent DW-MRI and MMSE preoperatively, at 24 hours postoperatively, at 6 months and at 12 months. Neurobiomarkers were assessed for each patient at six time-points. Thirty-two patients were submitted to CEA and 28 to CAS. No mortality was observed. One CAS patient presented with an ischemic stroke. In six CAS patients and one CEA patient, new subclinical ischemic lesions were detected at postoperative DW-MRI (21.4% versus 3%, P = 0.03). In CAS patients, new DW-MRI lesions were significantly associated with MMSE score decline (P = 0.001). At 12 months, patients presenting with new postoperative ischemic lesions showed lower MMSE scores (P = 0.08). CAS patients showed increasing neurobiomarker levels compared with CEA patients (P = 0.02). In conclusion, microembolization effects may persist over time, so it should be avoided whenever possible. Carotid revascularization procedures should be evaluated and compared not only with respect to death/stroke but also to microembolism rates
    corecore